Ejectors, steam/water requirements

Ejectors, steam/water requirements, 371 Electrical charge on tanks, 537 Electrical precipaiaiors, 280 Applications, 280, 282 Concept of operation, 281 Emergency relief, 450 Engineering, plant development, 46 Equipment symbols, 19—2 L Abbreviations, 25 Instruments, 21, 26. 29 Piping, 22 Valve codes, 26 Equivalent feel (flow), 86 Estimated design calculation time,... [Pg.627]

Humidification. For wiater operation, or for special process requirements, humidification maybe required (see Simultaneous HEAT and mass transfer). Humidification can be effected by an air washer which employs direct water sprays (see Evaporation). Regulation is maintained by cycling the water sprays or by temperature control of the air or water. Where a large humidification capacity is required, an ejector which direcdy mixes air and water in a no22le may be employed. Steam may be used to power the no22le. Live low pressure steam can also be released directly into the air stream. Capillary-type humidifiers employ wetted porous media to provide extended air and water contact. Pan-type humidifiers are employed where the required capacity is small. A water filled pan is located on one side of the air duct. The water is heated electrically or by steam. The use of steam, however, necessitates additional boiler feed water treatment and may add odors to the air stream. Direct use of steam for humidification also requires careful attention to indoor air quahty. [Pg.362]

Steam-Jet (Ejector) Systems These systems substitute an ejector for a mechanical compressor in a vapor compression system. Since refigerant is water, maintaining temperatures lower than the environment requires that the pressure of water in the evaporator must be... [Pg.1119]

Capacity Control The simplest way to regulate the capacity of most steam vacuum refrigeration systems is to furnish several primary boosters in parallel and operate only those required to handle the heat load. It is not uncommon to have as many as four main boosters on larger units for capacity variation. A simple automatic on-off type of control may be used for this purpose. By sensing the chilled-water temperature leaving the flash tank, a controller can turn steam on and off to each ejector as required. [Pg.1123]

Air is usually the basic load component to an ejector, and the quantities of water vapor and/or condensable vapor are usually directly proportional to the air load. Unfortunately, no reliable method exists for determining precisely the optimum basic air capacity of ejectors. It is desirable to select a capacity which minimizes the total costs of removing the noncondensable gases which accumulate in a process vacuum system. An oversized ejector costs more and uses unnecessarily large quantities of steam and cooling water. If an ejector is undersized, constant monitoring of air leaks is required to avoid costly upsets. [Pg.198]

Air/water vapor mixture, chart, 364,365 Air/water vapor, 359 Capacity at ejector suction, 369 Capacity for process vapor, 362 Evacuation time, 371, 380 Load for steam surface condenser, 367 Non-condensables, 362, 363 Size selection, 371 Steam pressure factor, 373 Steam requirements, 372 Steain/air mixture temperature, 361 Total weight saturated mixture, 362 Capacity, 358 Discharge, pressure, 358 Effect of excess steam pressure, 358 Effects of back pressure, 359 Effects of wet steam, 356 Inter-and-after condenser, 351 Load variation, 370 Materials of construction, 347 Molecular weight entrainment, chart, 360 Performance, 358, 370, 375 Relative comparison, 357... [Pg.626]

Figure 7.31. Steam requirements of ejectors at various pressure levels with appropriate numbers of stages and contact intercondensers. Steam pressure 100 psig, water temperature 85°F. Factor for 65 psig steam is 1.2 and for 200 psig steam it is 0.80 (Worthington Corp). Figure 7.31. Steam requirements of ejectors at various pressure levels with appropriate numbers of stages and contact intercondensers. Steam pressure 100 psig, water temperature 85°F. Factor for 65 psig steam is 1.2 and for 200 psig steam it is 0.80 (Worthington Corp).
Liquid-liner compressors produce an oil-free discharge of up to 125 psig. The efficiency is relatively low, 50% or so, but Wgh enough to make them superior to steam jet ejectors for vacuum service. The liquid absorbs the considerable heat of compression and must be circulated and cooled a 200 HP compressor requires 100 gpm of cooling water with a 10°F rise. When water vapor is objectionable in the compressed gas, other sealing liquids are used for example, sulfuric acid for the compression of chlorine. Figure 7.19(e) shows the principle and Table 7.10 gives specifications of some commercial units. [Pg.153]


See other pages where Ejectors, steam/water requirements is mentioned: [Pg.642]    [Pg.946]    [Pg.1292]    [Pg.139]    [Pg.1293]    [Pg.1127]    [Pg.96]    [Pg.550]    [Pg.982]    [Pg.478]    [Pg.1123]    [Pg.1438]    [Pg.163]    [Pg.642]    [Pg.26]    [Pg.365]    [Pg.365]    [Pg.41]    [Pg.820]    [Pg.37]    [Pg.153]    [Pg.151]    [Pg.478]    [Pg.123]    [Pg.139]    [Pg.163]    [Pg.1261]    [Pg.37]    [Pg.153]    [Pg.34]    [Pg.143]    [Pg.38]    [Pg.37]    [Pg.153]   
See also in sourсe #XX -- [ Pg.371 ]




SEARCH



Ejector, steam

Ejectors Steam requirements

Ejectors Water

Water requirements

© 2024 chempedia.info