Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Eight Sources

This study has demonstrated that precise chemical analysis is a powerful tool for the characterization and provenance determination of Middle Eastern obsidian. Thirteen to 15 chemically distinctive groups were distinguishable in geological source samples collected from eight source... [Pg.39]

Identify EIGHT sources of information that might usefully be consulted when developing a safe system of work for a construction activity. [Pg.98]

In 1970, Goda presented a diagram of breaker index curves of regular waves for four bed slopes, based on the laboratory data from eight sources, which included his own large-scale tests with Hb = 0.43 to 0.93m Rattanapitikon et al did not... [Pg.90]

In essence, a guided-ion beam is a double mass spectrometer. Figure A3.5.9 shows a schematic diagram of a griided-ion beam apparatus [104]. Ions are created and extracted from an ion source. Many types of source have been used and the choice depends upon the application. Combining a flow tube such as that described in this chapter has proven to be versatile and it ensures the ions are thennalized [105]. After extraction, the ions are mass selected. Many types of mass spectrometer can be used a Wien ExB filter is shown. The ions are then injected into an octopole ion trap. The octopole consists of eight parallel rods arranged on a circle. An RF... [Pg.811]

Eight years after MACT is installed on a source, EPA must examine the risk levels remaining at the regulated facilities and determine whether additional controls are necessary to reduce unacceptable residual risk. [Pg.400]

The information obtained during the background search and from the source inspection will enable selection of the test procedure to be used. The choice will be based on the answers to several questions (1) What are the legal requirements For specific sources there may be only one acceptable method. (2) What range of accuracy is desirable Should the sample be collected by a procedure that is 5% accurate, or should a statistical technique be used on data from eight tests at 10% accuracy Costs of different test methods will certainly be a consideration here. (3) Which sampling and analytical methods are available that will give the required accuracy for the estimated concentration An Orsat gas analyzer with a sensitivity limit of 0.02% would not be chosen to sample carbon monoxide... [Pg.537]

The Air Force Dispersion Assessment Model (ADAM -1980s) calculates the source term and dispersion of accidental releases of eight specific chemicals chlorine, fluorine, nitrogen tetroji ogen sulfide, hydrogen fluoride, sulfur dioxide, phosgene, and ammonia. It Ut a ... [Pg.347]

Failure data from eight PWRs and nine BWRs for 1972 and from varied non-nuclear industry sources... [Pg.116]

The bicyclic compound 8.17 also serves as a source of the five-membered ring 8.20 upon reduction with SbPhs. In contrast to the related S or Se systems, 8.11a and 8.11b, both Cl substituents are attached covalently to Te in 8.20. Reaction of 8.20 with an excess of AsFs in SO2 produces the eight-membered cyclic [Tc2S2N4] dication, which exhibits a Te-Te bond length of 2.88 A (cf. 2.70 A for a Te-Te single bond) and no transannular S S bonding J... [Pg.155]

The 1,5-isomers 13.3 (E = S) are colourless, air-stable solids. They are prepared by the cyclocondensation reaction of R2PN2(SiMe3)3 with sulfur dichloride or thionyl chloride. A similar cyclocondensation process, using a mixture of SeCU and Sc2Cl2 as a source of selenium, produces a mixture of the isomers 13.2 and 13.3 (E = Se, R = Ph). The structures of 13.3 (E = S, R = alkyl, aryl) are folded eight-membered rings with a cross-ring S S distance of ca. 2.50 This structural... [Pg.262]

Ninety-eight per cent of the world s supply of platinum metals comes from three countries — the former Soviet Union (49%), the Republic of South Africa (43%), and Canada (6%). Because of the different proportions of Pt and Pd in their deposits, the Republic of South Africa is the major source of Pt and the former USSR of Pd. Only in the RSA (where the Bushveld complex contains over 70% of the world s reserves of the platinum metals at concentrations of 8-9 grams per tonne) are the... [Pg.1146]

Here the integration J dr is over the coordinates of both electrons. Such integrals are therefore eight-dimensional (three spatial variables and one spin variable per electron). Integration over the spin variables is straightforward, but the spatial variables are far from easy a particular source of trouble arises from the electron repulsion term. [Pg.92]


See other pages where Eight Sources is mentioned: [Pg.349]    [Pg.210]    [Pg.543]    [Pg.19]    [Pg.35]    [Pg.111]    [Pg.505]    [Pg.349]    [Pg.210]    [Pg.543]    [Pg.19]    [Pg.35]    [Pg.111]    [Pg.505]    [Pg.375]    [Pg.400]    [Pg.49]    [Pg.438]    [Pg.373]    [Pg.450]    [Pg.342]    [Pg.511]    [Pg.27]    [Pg.85]    [Pg.391]    [Pg.406]    [Pg.579]    [Pg.16]    [Pg.2158]    [Pg.177]    [Pg.63]    [Pg.400]    [Pg.5]    [Pg.13]    [Pg.250]    [Pg.315]    [Pg.421]    [Pg.264]    [Pg.246]    [Pg.260]    [Pg.262]    [Pg.2]    [Pg.232]   


SEARCH



© 2024 chempedia.info