The next step is to develop a method to determine the overall reUabiUty and failure probabiUty for systems constmcted of a variety of individual components. This requires an understanding of how components are linked. Components are linked either in series or in parallel. For series linkages, overall failure results from the failure of any of the components. For parallel linkages, all of the components must fad. An example of a series linkage is an automobde. The car is disabled if a flat occurs in any one of the four tires. This situation is linked in parallel to the spare tire. The car is completely disabled oidy if a flat occurs and the spare tire is flat. [Pg.476]

The Americans with Disabilities Act (ADA) has opened another market for scrap tires in resilient playground surfacing. Many schools and recreation facilities ate reconfiguring playgrounds to make them more accessible, including the use of resilient surfaces which can be traversed by wheelchairs. [Pg.20]

Inhalation of crystalline or fused vitreous silica dust, usually overlong periods, causes a disabling, progressive pulmonary disease known as silicosis (84). Amorphous siUcas have not been linked to siUcosis (85), but can cause respiratory irritation. The history and poHtics of siUcosis have been reviewed (86). Standards have been set or recommended for occupational exposures (87,88) and review articles on the health effects of siUca are available (83,89). [Pg.480]

The principal health hazard that may be associated with shicon and shicon alloys is caused by the crystalline form of the oxide, ie, quartz, used as a raw material. Shica ia its crystalline form is the chief cause of disabling pulmonary fibrosis, such as shicosis. Over a period of years, the breathing of air containing excessive amounts of crystalline shica can cause shortness of breath (30). [Pg.541]

Indirect savings include work loss, death,and disability... [Pg.362]

The heat removal capability to be used usually depends on the product being manufactured. Therefore, regulatory loops must be configured for each possible option, and sometimes for certain combinations of the possible options. These loops are enabled and disabled depending on the product being manufactured. [Pg.755]

The controller action can be disabled by triggering a binary deactivate input signal, during process startup, shutdown, or when some abnormal conditions exist. [Pg.773]

Ensure that SIS is not disabled when operating in manual mode... [Pg.122]

A pressure limiting controller, in the event of excessively high absolute pressure in the regenerator, disables the differential pressure controller and limits the pressure to a preset maximum value. [Pg.383]

The industries which produce and handle various stone products emit considerable amounts of particulate matter at every stage of the operation. These particulates may include fine mineral dusts of a size to cause damage to the lungs. The threshold values for such dusts have been set quite low to prevent disabling diseases for the worker. [Pg.89]

In this example, the error amp on the eontrol IC (a UC3843AP) is disabled by wiring the inputs of the error amp so that the output is guaranteed to be high. The values of R are not important (say 10K eaeh). The eompensation pin has a 1mA eurrent souree internally and has a high voltage of +4.5 V for the full output eondition. [Pg.79]

List the diseases prescnbed for the payment of disablement benefit, if related to specific occupations. Conditions due to chemical agents, e.g. poisoning by any of a range of chemicals and certain carcinomas, and miscellaneous conditions, e.g. pneumoconiosis, asthma, diffuse mesothelioma, non-mfective dermatitis are included. [Pg.596]

A small percentage of the population may be sensitive to a number of chemicals in indoor air, each of which may occur at very low concentrations. The existence of this condition, which is known as multiple chemical sensitivity (MCS), is a matter of considerable controversy. MCS is not currently recognized by the major medical organizations. Medical opinion is divided, and further research is needed. The applicability of access for the disabled and worker s compensation regulations to... [Pg.196]

A distributed control system (DCS) normally uses input and output modules which contain eight, sixteen, or more inputs or outputs. Failure of the module will simultaneously disable a large number of control loops. Attention to the assignment of input/output points to the modules makes the plant more tolerant of a failure of an input or output module (CCPS, 1993a). For a more detailed discussion of process control systems, see the process control part of Section 4.4, and Sections 6.4 and 6.5. [Pg.51]

We later learned that water valves with lever handles (frequently seen in hospitals or in sinks intended for disabled persons) are designed for the lever to be pushed away from the user to close the valve. Thus, the cold water valve designed for a lever will turn to the left to close. If a round handle is fitted instead of the lever. . . splash ... [Pg.105]

To determine which jobs you should analyze first, review your injury and illness reports such as the OSHA 200 log, your medical case histories, your first-aid cases, and workers compensation claims. First, you should conduct a JHA for jobs with the highest rates of disabling injuries and illnesses. Do not forget jobs in which you have had close calls or near hits. You should give these incidents a high priority. Analyses of new jobs and jobs in which changes have been made in processes and procedures should be the next priority. [Pg.44]

Because these trips are disabled by a loss nf cooling signal, they should be disregarded in calculating the diesel reliability in a loss of cooling sequence. If liic trip were bypassed the diesel would have failed, and it is counted as a failure. [Pg.161]

External events are accident initiators that do not fit well into the central PSA structure used for "internal events." Some "external events" such as fire due to ignition of electrical wires, or flood from a ruptured service water pipe occur inside the plant. Others, such as earthquakes and tornados, occur outside of the plant. Either may cause failures in a plant like internal events. External initiators may cause multiple failures of independent equipment thereby preventing action of presumably redundant protection systems. For example, severe offsite flooding may fli 1 the pump room and disable cooling systems. An earthquake may impede evacuation of the nearby populace. These multiple effects must be considered in the analysis of the effects of external events. [Pg.185]

Identify critical locations where fires can cause an initiating event that could fail redundant engineered safety functions, or disable redundant and diverse safety-related equipment. [Pg.196]


See other pages where Disablement is mentioned: [Pg.389]    [Pg.175]    [Pg.374]    [Pg.273]    [Pg.441]    [Pg.525]    [Pg.236]    [Pg.38]    [Pg.92]    [Pg.233]    [Pg.317]    [Pg.457]    [Pg.2302]    [Pg.40]    [Pg.331]    [Pg.483]    [Pg.80]    [Pg.2]    [Pg.17]    [Pg.77]    [Pg.198]    [Pg.589]    [Pg.44]    [Pg.44]    [Pg.46]    [Pg.47]    [Pg.538]    [Pg.88]    [Pg.88]    [Pg.89]    [Pg.125]    [Pg.142]   