Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Direct basic principles

The aim of this first fundamental framework EU directive 80/1107/EEC - today no longer in force - was the protection of workers against risks to their health and safety arising from exposure to chemical, physical, and biological agents. It included measures for the prevention of such risks as far as they are considered to be harmful. The risk of radiation and air and sea transport is outside the scope of the directive. Basic principles are the avoidance of exposure to agents or keeping it to as low a level as is reasonably practicable. [Pg.148]

Distillers vary masking procedures, but generally conform to basic principles, especially in the maintenance of sanitary conditions. The cooking and conversion equipment is provided with direct or indirect steam, propeller agitation, and cooling coils. [Pg.84]

The mass-transfer coefficients depend on complex functions of diffii-sivity, viscosity, density, interfacial tension, and turbulence. Similarly, the mass-transfer area of the droplets depends on complex functions of viscosity, interfacial tension, density difference, extractor geometry, agitation intensity, agitator design, flow rates, and interfacial rag deposits. Only limited success has been achieved in correlating extractor performance with these basic principles. The lumped parameter deals directly with the ultimate design criterion, which is the height of an extraction tower. [Pg.1464]

The abundance of a trace element is often too small to be accurately quantihed using conventional analytical methods such as ion chromatography or mass spectrometry. It is possible, however, to precisely determine very low concentrations of a constituent by measuring its radioactive decay properties. In order to understand how U-Th series radionuclides can provide such low-level tracer information, a brief review of the basic principles of radioactive decay and the application of these radionuclides as geochronological tools is useful. " The U-Th decay series together consist of 36 radionuclides that are isotopes (same atomic number, Z, different atomic mass, M) of 10 distinct elements (Figure 1). Some of these are very short-lived (tj j 1 -nd are thus not directly useful as marine tracers. It is the other radioisotopes with half-lives greater than 1 day that are most useful and are the focus of this chapter. [Pg.35]

Ammonia activation by Pt, to be discussed in the next section, is an interesting example, because it illustrates the basic principle that provides chemical direction to the identification of surface topologies that give low reaction barriers in surface reactions. This holds specifically for elementary reactions that require a surface ensemble of atoms. [Pg.25]

The beauty of finite-element modelling is that it is very flexible. The system of interest may be continuous, as in a fluid, or it may comprise separate, discrete components, such as the pieces of metal in this example. The basic principle of finite-element modelling, to simulate the operation of a system by deriving equations only on a local scale, mimics the physical reality by which interactions within most systems are the result of a large number of localised interactions between adjacent elements. These interactions are often bi-directional, in that the behaviour of each element is also affected by the system of which it forms a part. The finite-element method is particularly powerful because with the appropriate choice of elements it is easy to accurately model complex interactions in very large systems because the physical behaviour of each element has a simple mathematical description. [Pg.155]

The basic principle underlying the development of images is simple (Lauterber, 1973). Consider a body cavity containing two pools of water in different quantities. In a uniform magnetic field, the NMR spectrum will consist of a single peak, since all the water molecules will process at the same frequency, irrespective of their spatial location. If, however, a linear field gradient is applied in the x -direction, the Larmor frequency of the water will increase linearly across the sample as a function of the x -coordinate, thereby creating a one-dimensional profile, or spectrum, of the sample (Fig. 7.21). [Pg.383]

Quality control is intended to monitor and evaluate the performances of both food and human processes that contribute to food quality. The basic principle of this function is the control circle that involves (1) the taking of a process sample by the analysis or measuring unit, (2) determining whether process results meet set tolerances or limits, (3) judging the character and level of any discrepancy, and (4) application of corrective action to adjust the system to an acceptable level (Figure 7.1.1). A distinction is made between measuring and analysis, whereby the first involves direct measurements (e.g., pH, temperature) and the second involves taking samples, sample preparation, and actual analysis. ... [Pg.555]

Many and varied field techniques involved in the planning, execution, and direction of the field portion of worker exposure and re-entry studies have been considered. Suffice it to say that there are many ways to perform such studies, and the important thing to remember is that good scientific thought and planning will produce an excellent study. The scientific validity of such studies should rest on the basic principles of science. There are various guidelines and protocols which may be followed for regulatory... [Pg.1024]

The design of water-cooling towers, and humidification, is covered in Volume 1, Chapter 13. The same basic principles will apply to the design of other direct-contact exchangers. [Pg.767]

This simple example illustrates the basic principles of water network design for maximum reuse for a single contaminant. A number of issues need to be considered that would apply to more complex examples. Consider Figure 26.25 involving three water mains and three operations. Operation 2 above the pinch terminates at a concentration less than the concentration for the high concentration water main. The outlet of Operation 2 must not be fed directly into this final water main. The basis of the mass balance from Figure 26.17 dictates that all streams must achieve the concentration of the water mains into... [Pg.598]

This map has been checked by many researchers, indicating that it is applicable to a wide range of conditions. Also shown in Figure 3.4 are correlations derived by Mishima and Ishii (1984), which used similar basic principles except for the slug-to-churn transition. These authors pointed out that, in view of the practical applications of the separate-fluid model to transient analysis, flow regime criteria based on the superficial velocities of the liquid and gas may not be consistent with the separate-flow model formulation. A direct geometric parameter such as the... [Pg.155]


See other pages where Direct basic principles is mentioned: [Pg.2656]    [Pg.310]    [Pg.307]    [Pg.21]    [Pg.57]    [Pg.481]    [Pg.176]    [Pg.413]    [Pg.173]    [Pg.135]    [Pg.248]    [Pg.100]    [Pg.31]    [Pg.19]    [Pg.1637]    [Pg.2490]    [Pg.205]    [Pg.265]    [Pg.244]    [Pg.252]    [Pg.46]    [Pg.232]    [Pg.690]    [Pg.709]    [Pg.93]    [Pg.377]    [Pg.252]    [Pg.29]    [Pg.470]    [Pg.23]    [Pg.706]    [Pg.575]    [Pg.181]    [Pg.598]    [Pg.117]    [Pg.166]   
See also in sourсe #XX -- [ Pg.111 , Pg.112 ]




SEARCH



Direct principle

© 2024 chempedia.info