Difference ultraviolet/visible spectroscopy, photosystem 11, 33 225-228 Diffusion, conversion of radial to linear, 36 352-353... [Pg.78]

Van der Waals complexes can be observed spectroscopically by a variety of different teclmiques, including microwave, infrared and ultraviolet/visible spectroscopy. Their existence is perhaps the simplest and most direct demonstration that there are attractive forces between stable molecules. Indeed the spectroscopic properties of Van der Waals complexes provide one of the most detailed sources of infonnation available on intennolecular forces, especially in the region around the potential minimum. The measured rotational constants of Van der Waals complexes provide infonnation on intennolecular distances and orientations, and the frequencies of bending and stretching vibrations provide infonnation on how easily the complex can be distorted from its equilibrium confonnation. In favourable cases, the whole of the potential well can be mapped out from spectroscopic data. [Pg.2439]

The techniques considered in this chapter are infrared spectroscopy (or vibrational spectroscopy), nuclear magnetic resonance spectroscopy, ultraviolet-visible spectroscopy (or electronic spectroscopy) and mass spectrometry. Absorption of infrared radiation is associated with the energy differences between vibrational states of molecules nuclear magnetic resonance absorption is associated with changes in the orientation of atomic nuclei in an applied magnetic field absorption of ultraviolet and visible radiation is associated with changes in the energy states of the valence electrons of molecules and mass spectrometry is concerned... [Pg.254]

Quantitative infrared spectroscopy suffers certain disadvantages when compared with other analytical techniques and thus it tends to be confined to specialist applications. However, there are certain applications where it is used because it is cheaper or faster. The technique is often used for the analysis of one component of a mixture, particularly when the compounds in the mixture are alike chemically or haye very similar physical properties, e.g. structural isomers. In these cases, analysis by using ultraviolet/visible spectroscopy is difficult because the spectra of the components will be almost identical Chromatographic analysis may be of limited use because the separation of isomers, for example, is difficult to achieve. The infrared spectra of isomers are usually quite different in the fingerprint region. Another advantage of the infrared technique is that it is non-destructive and requires only a relatively small amount of sample. [Pg.85]

In view of the unusual mechanism of anionic polymerization, especially the absence of termination and chain transfer reactions, the kinetics of these systems can be treated quite differently than for the other mechanisms. Thus it is possible, by suitable experimental techniques, to examine separately the rates of the initiation and propagation reactions [172,173], since the stable organometallic chain ends are present in concentrations [10 -10 M] which are easily measured by ultraviolet-visible spectroscopy [174]. The propagation reaction is, of course, of considerable main interest and can be studied by making sure that initiation is complete. In this way, the kinetics of homogeneous anionic polymerization have been extensively elucidated with special reference to the nature of counterion and role of the solvent. [Pg.72]

FIGURE 2.4 Different strategies for performing BIA. (AS, atomic spectroscopy MS, mass spectrometry UV/Vis, ultraviolet-visible spectroscopy.) (Modified with permission from J. Ruzicka, Flow Injection Analysis, 2014, http //www.flowinjectiontutorial.com.)... [Pg.42]

The preceding empirical measures have taken chemical reactions as model processes. Now we consider a different class of model process, namely, a transition from one energy level to another within a molecule. The various forms of spectroscopy allow us to observe these transitions thus, electronic transitions give rise to ultraviolet—visible absorption spectra and fluorescence spectra. Because of solute-solvent interactions, the electronic energy levels of a solute are influenced by the solvent in which it is dissolved therefore, the absorption and fluorescence spectra contain information about the solute-solvent interactions. A change in electronic absorption spectrum caused by a change in the solvent is called solvatochromism. [Pg.435]

IR spectroscopy, unlike ultraviolet-visible (UV-Vis) spectroscopy, can be used to directly measure both inorganic and organic components in soil, although it is more commonly used to identify organic compounds. It is carried out in two different wavelength ranges, the NIR, which is from 0.8 to 2.5 pm (800-2500 nm), and the MIR, which is from 2.5 to 25 pm (4000-400 cm ). ... [Pg.178]

There have been relatively little ultraviolet-visible (UV-Vis) spectroscopic data for 1,4-oxazines, but selected data are presented in Table 8. UV spectroscopy is important for photochromic compounds, such as spirooxazines. The UV spectra of 33 spirooxazines in five different solvents are collected in a review <2002RCR893>, and the more recently reported examples of photochromic oxazines 65, 66, 101, and 102 are shown here. It can be seen from Table 8 that both adding methoxy substituents to the oxazine and changing to a more polar solvent give a UV maximum at a higher wavelength. This solvent effect can also be seen in the case of 102, which also has important fluorescence properties, discussed in Section 8.06.12.2. [Pg.471]


See other pages where Difference ultraviolet/visible spectroscopy is mentioned: [Pg.225]    [Pg.225]    [Pg.174]    [Pg.596]    [Pg.425]    [Pg.212]    [Pg.174]    [Pg.47]    [Pg.425]    [Pg.459]    [Pg.215]    [Pg.57]    [Pg.313]    [Pg.120]    [Pg.333]    [Pg.134]    [Pg.231]    [Pg.232]    [Pg.213]    [Pg.585]    [Pg.521]    [Pg.468]    [Pg.60]    [Pg.188]    [Pg.245]    [Pg.42]    [Pg.145]    [Pg.67]    [Pg.137]    [Pg.528]    [Pg.141]    [Pg.141]    [Pg.30]    [Pg.186]    [Pg.287]    [Pg.314]    [Pg.515]    [Pg.321]   


SEARCH



Difference spectroscopy

Spectroscopy ultraviolet visible

Ultraviolet difference spectroscopy

Ultraviolet spectroscopy

Ultraviolet-visible

© 2024 chempedia.info