Detection Using Instrumentation

As in the case of the purple photosynthetic bacteria, the more stable electron acceptor of green filamentous bacteria was first detected using instrumentation with millisecond-time resolution and so the rise and decay kinetics of any earlier electron acceptor(s) would be too fast to be detected. The detection of any earlier electron acceptor would require greater time resolution, such as afforded by picosecond spectroscopy. As a framework for further discussion we write the sequence of the primary photochemical and electron-transfer reactions in green filamentous bacteria as follows ... [Pg.172]

Table 10.21 Considerations when using instruments with catalytic detection... Table 10.21 Considerations when using instruments with catalytic detection...
Thermography is a predictive maintenance technique that can be used to monitor the condition of plant machinery, structures and systems. It uses instrumentation designed to monitor the emission of infrared energy, i.e. temperature, to determine their operating condition. By detecting thermal anomalies, i.e. areas that are hotter or colder than they should be, an experienced surveyor can locate and define incipient problems within the plant. [Pg.799]

Detecting and Predicting Climate Change Effects in Reservoirs Using Instrumental Data... [Pg.82]

The mass range requirement invariably means that FAB is used in conjunction with a magnetic sector instrument. Conventional detectors, such as the electron multiplier, are not efficient for the detection of large ions and the necessary sensitivity is often only obtained when devices such as the post-acceleration detector or array detector are used. Instruments capable of carrying out high-mass investigations on a routine basis are therefore costly and beyond the reach of many laboratories. [Pg.157]

Later work by several research workers, and most particularly Greef (1969), showed that the very early stages of oxide film formation could be detected using more sensitive instrumentation and the changes in A, 4 and the light intensity correlated very well with the charge passed both in the anodic and cathodic sweeps (see Figure 3.13). [Pg.256]

On account of having the same number of electrons and protons, isotopes of a given element have identical chemical properties and reactivity. However, since they differ in the number of neutrons, they have different atomic masses. As MS measures and discriminates mass, isotopes are detected and they are present in every mass spectrum, independent of the ionization technique used, instrumentation, etc. [Pg.64]

Ion mobility spectrometry (IMS) [3,12] is the most widely used instrument for drug detection. The sample is heated to vaporize the analyte, which is then ionized by atmospheric (ambient) pressure chemical ionization (APCI) [3]. The resulting gas-phase ions travel through a drift tube and are separated by their distinct velocities (mobilities) in a weak electrostatic field. IMS instruments use ambient air or nitrogen as the carrier gas, making it particularly adaptable to field applications. [Pg.793]

The radiopharmaceuticals used for diagnostic imaging usually satisfy the following requirements (1) radiation from the nuclide penetrates the body and is detectable by instrumentation (requires emission of photons of energy >35 KeV, preferably >80 KeV (268)) and... [Pg.226]

FIGURE7.14 Instrumental setup for CE-NMR with online NMR detection using a solenoidal microcoil probe. [Pg.381]

At each Post, following a presentation by the briefing team, those still interested stayed in their seats and filled out the numerous pages of the personal history form. Then they spent up to an hour and a half completing the Minnesota Multiphasic Personality Inventory (MMPI), a widely used instrument for detecting psychiatric problems or profiling personality characteristics. [Pg.32]

Unfortunately, this technique is not selective and all components are affected in the same way so that if exact co-elution of sample components occurs, this may not be detected. Using a single quadrupole instrument limits the user to using in-source fragmentation, but in many cases this can provide enough information to identify unknowns. [Pg.171]


See other pages where Detection Using Instrumentation is mentioned: [Pg.87]    [Pg.145]    [Pg.87]    [Pg.145]    [Pg.318]    [Pg.268]    [Pg.804]    [Pg.174]    [Pg.4]    [Pg.395]    [Pg.448]    [Pg.865]    [Pg.244]    [Pg.401]    [Pg.629]    [Pg.411]    [Pg.375]    [Pg.224]    [Pg.190]    [Pg.349]    [Pg.43]    [Pg.664]    [Pg.50]    [Pg.338]    [Pg.379]    [Pg.111]    [Pg.151]    [Pg.192]    [Pg.513]    [Pg.74]    [Pg.1091]    [Pg.142]    [Pg.520]    [Pg.340]    [Pg.115]    [Pg.220]   