Detection choice

Although absorptiometric detection via preceding colour reactions is still mainly used, CFA has shown increasing versatility not only in detection choice but also in sample pre-treatment, such as (partial) dialysis, distillation, evaporation to dryness, digestion, long-term incubation and coated-tube separation a review was published by Snyder83. [Pg.353]

From the practical point of view, dual-channel phase detectors operated in quadrature appear to be the best hardware-detection choice. Unlike other techniques, phase detection is sensitive to RF frequency offset from resonance and to the RF phase which, on the one hand, makes the signals more complex to use (as well as and more sensitive to instrument instabilities) but, on the other hand, leads to a number of important advantages, such as ... [Pg.455]

There is, however, a difficulty in interpreting the outcome of these tests of free operant performance, in that it is extremely difficult to distinguish whether the recorded impairments involve an underlying deficit in the motor, sensory or motivational function (Hamilton et al., 1985 Cousins and Salamone, 1996b). Attention has therefore turned to tests in which animals are trained to make rapid movements in response to an imperative stimulus in discrete trial tasks, in which specific changes in signal detection, choice accuracy, reaction time and movement latency can potentially distinguish sensory, motor and motivational components of the deficit. [Pg.263]

The procedure for aptamer selection by NECEEM would typically start with measurement of the migration times of the target and the naive library (leftmost and rightmost peaks in Figure 9.4). Since the target is typically not labeled lluorescently, ultraviolet (UV) light absorption is the detection choice for the target. UV detection can also be used for the naive library. Alternatively, the... [Pg.188]

The choice between X-ray fluorescence and the two other methods will be guided by the concentration levels and by the duration of the analytical procedure X-ray fluorescence is usually less sensitive than atomic absorption, but, at least for petroleum products, it requires less preparation after obtaining the calibration curve. Table 2.4 shows the detectable limits and accuracies of the three methods given above for the most commonly analyzed metals in petroleum products. For atomic absorption and plasma, the figures are given for analysis in an organic medium without mineralization. [Pg.38]

The case of thin-skin regime appears in various industrial sectors such as aerospace (with aluminium parts) and also nuclear in tubes (with ferromagnetic parts or mild steel components). The detection of deeper defects depends of course on the choice of the frequency and the dimension of the probe. Modelling can evaluate different solutions for a type of testing in order to help to choose the best NDT system. [Pg.147]

In contrast to a direct injection of dc or ac currents in the sample to be tested, the induction of eddy currents by an external excitation coil generates a locally limited current distribution. Since no electrical connection to the sample is required, eddy current NDE is easier to use from a practical point of view, however, the choice of the optimum measurement parameters, like e.g. the excitation frequency, is more critical. Furthermore, the calculation of the current flow in the sample from the measured field distribution tends to be more difficult than in case of a direct current injection. A homogenous field distribution produced by e.g. direct current injection or a sheet inducer [1] allows one to estimate more easily the defect geometry. However, for the detection of technically relevant cracks, these methods do not seem to be easily applicable and sensitive enough, especially in the case of deep lying and small cracks. [Pg.255]

Following the movement of airborne pollutants requires a natural or artificial tracer (a species specific to the source of the airborne pollutants) that can be experimentally measured at sites distant from the source. Limitations placed on the tracer, therefore, governed the design of the experimental procedure. These limitations included cost, the need to detect small quantities of the tracer, and the absence of the tracer from other natural sources. In addition, aerosols are emitted from high-temperature combustion sources that produce an abundance of very reactive species. The tracer, therefore, had to be both thermally and chemically stable. On the basis of these criteria, rare earth isotopes, such as those of Nd, were selected as tracers. The choice of tracer, in turn, dictated the analytical method (thermal ionization mass spectrometry, or TIMS) for measuring the isotopic abundances of... [Pg.7]

Choice of Atomization and Excitation Source Except for the alkali metals, detection limits when using an ICP are significantly better than those obtained with flame emission (Table 10.14). Plasmas also are subject to fewer spectral and chemical interferences. For these reasons a plasma emission source is usually the better choice. [Pg.437]

Methods to Detect and Quantitate Viral Agents in Fluids. In order to assess the effectiveness of membrane filtration the abihty to quantitate the amount of vims present pre- and post-filtration is critical. There are a number of techniques used. The method of choice for filter challenge studies is the plaque assay which utilizes the formation of plaques, localized areas in the cell monolayer where cell death caused by viral infection in the cell has occurred on the cell monolayer. Each plaque represents the presence of a single infectious vims. Vims quantity in a sample can be determined by serial dilution until the number of plaques can be accurately counted. The effectiveness of viral removal may be determined, as in the case of bacterial removal, by comparing the vims concentration in the input suspension to the concentration of vims in the effluent. [Pg.143]

Inductively coupled plasma (icp) emission, direct current plasma (dcp), and inductively coupled plasma mass spectrometry (icp/ms) have taken over as the methods of choice for the simultaneous detection of metallic impurities in hafnium and hafnium compounds (29,30). [Pg.443]

Because of the increasing emphasis on monitoring of environmental cadmium the detemiination of extremely low concentrations of cadmium ion has been developed. Table 2 Hsts the most prevalent analytical techniques and the detection limits. In general, for soluble cadmium species, atomic absorption is the method of choice for detection of very low concentrations. Mobile prompt gamma in vivo activation analysis has been developed for the nondestmctive sampling of cadmium in biological samples (18). [Pg.393]


See other pages where Detection choice is mentioned: [Pg.147]    [Pg.157]    [Pg.452]    [Pg.1169]    [Pg.123]    [Pg.1763]    [Pg.1097]    [Pg.507]    [Pg.147]    [Pg.157]    [Pg.452]    [Pg.1169]    [Pg.123]    [Pg.1763]    [Pg.1097]    [Pg.507]    [Pg.71]    [Pg.256]    [Pg.359]    [Pg.362]    [Pg.1164]    [Pg.1185]    [Pg.1449]    [Pg.1574]    [Pg.1781]    [Pg.1933]    [Pg.2483]    [Pg.2485]    [Pg.50]    [Pg.416]    [Pg.260]    [Pg.268]    [Pg.412]    [Pg.3]    [Pg.49]    [Pg.510]    [Pg.131]    [Pg.428]    [Pg.171]    [Pg.439]    [Pg.244]    [Pg.6]    [Pg.71]    [Pg.232]    [Pg.136]    [Pg.1749]    [Pg.2578]   
See also in sourсe #XX -- [ Pg.9 ]