Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Deaerators forming section

Selection of the high pressure steam conditions is an economic optimisation based on energy savings and equipment costs. Heat recovery iato the high pressure system is usually available from the process ia the secondary reformer and ammonia converter effluents, and the flue gas ia the reformer convection section. Recovery is ia the form of latent, superheat, or high pressure boiler feedwater sensible heat. Low level heat recovery is limited by the operating conditions of the deaerator. [Pg.353]

Leaving aside FW deaeration (which is usually provided as the final type of external treatment in the pre-boiler section), the primary forms of treatment processes commonly employed can be conveniently categorized into three areas ... [Pg.306]

The earlier sections of this chapter discuss the mixed electrode as the interaction of anodic and cathodic reactions at respective anodic and cathodic sites on a metal surface. The mixed electrode is described in terms of the effects of the sizes and distributions of the anodic and cathodic sites on the potential measured as a function of the position of a reference electrode in the adjacent electrolyte and on the distribution of corrosion rates over the surface. For a metal with fine dispersions of anodic and cathodic reactions occurring under Tafel polarization behavior, it is shown (Fig. 4.8) that a single mixed electrode potential, Ecorr, would be measured by a reference electrode at any position in the electrolyte. The counterpart of this mixed electrode potential is the equilibrium potential, E M (or E x), associated with a single half-cell reaction such as Cu in contact with Cu2+ ions under deaerated conditions. The forms of the anodic and cathodic branches of the experimental polarization curves for a single half-cell reaction under charge-transfer control are shown in Fig. 3.11. It is emphasized that the observed experimental curves are curved near i0 and become asymptotic to E M at very low values of the external current. In this section, the experimental polarization of mixed electrodes is interpreted in terms of the polarization parameters of the individual anodic and cathodic reactions establishing the mixed electrode. The interpretation then leads to determination of the corrosion potential, Ecorr, and to determination of the corrosion current density, icorr, from which the corrosion rate can be calculated. [Pg.150]

Air bubbles. Carrier stream not deaerated gases are formed as a result of a chemical reaction (e.g., CO2 see Section 6.2) or due to a Venturi effect in the flow cell, caused by the sudden decrease of pressure in the flow cell, owing to a larger inner diameter of the flow cell terminals than of that of the tube used. This effect can be eliminated by inserting the connecting tubes all the way into the terminals, so that the orifices of the tubes are as close as possible to the actual cell chamber, and by... [Pg.318]


See other pages where Deaerators forming section is mentioned: [Pg.183]    [Pg.313]    [Pg.20]    [Pg.2047]    [Pg.2457]    [Pg.328]    [Pg.458]    [Pg.195]    [Pg.60]    [Pg.108]    [Pg.261]    [Pg.195]   
See also in sourсe #XX -- [ Pg.258 ]




SEARCH



Deaerate

Deaerating

Deaeration

Deaerator

Forming sections

© 2024 chempedia.info