Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Curve-fitting software

When structure-property relationships are mentioned in the current literature, it usually implies a quantitative mathematical relationship. Such relationships are most often derived by using curve-fitting software to find the linear combination of molecular properties that best predicts the property for a set of known compounds. This prediction equation can be used for either the interpolation or extrapolation of test set results. Interpolation is usually more accurate than extrapolation. [Pg.243]

They provide a more accurate method for the simultaneous determination of formation and decay rate constants using curve-fitting software. [Pg.183]

Alternatively, in the absence of curve-fitting software, the equation can be re-written in a straight line form and then the same linear regression method, as for the Arrhenius method, used to find the coefficients. The straight line form is given by ... [Pg.106]

The behavior of metabolites may often be modeled reasonably well, but determining the various parameters for metabolites is a challenge. Specialized pharmacokinetic curve-fitting software frequently can tease the parameters from clinical Cp-time data. If necessary, metabolites may be synthesized in lab and then administered directly to animals. From these studies, key parameters such as Vd, CL, F, and kah may be determined in the absence of the parent drug. Keep in mind that a pharmaceutical company may not administer a metabolite into humans without the metabolite s being classified as an investigational new drug (IND). [Pg.182]

In figure 12.19 the contributions of the three bands in the silane stretching region (established by curve fitting software) are correlated versus the percentage of secondary species on the surface, as determined by NMR. [Pg.415]

We use our own curve-fitting software based on program listings and explanations of curve-fitting procedures provided by Barlow (7). However, current proprietary software packages for analysis of data generated by 96-well plate readers should permit this type of analysis. [Pg.127]

Before the widespread availability of non-linear curve-fitting software, the individual parameters and fccat were separated by means of a Lineweaver-Burk plot, in which 1/v was plotted against 1/[S]. The plot should be a straight line with a y intercept of x intercept of—l/K, ... [Pg.304]

However, they can be put in linear form by data transformation. Fitting these functions by least squares is not necessarily straightforward, but fortunately there are user-friendly curve fitting software utilities included with most major spreadsheets and statistical packages that will find the best fit for these and other functions. [Pg.53]

The NMR spectra were recorded on a Varian SC-300 spectrometer in Fourier transform mode at 300 MHz. When measured in H2O solution, the intensity of the solvent line was reduced by irradiation of water signal for 2s prior to the observation pulse. The pH measurements were carried out directly in the 5 mm o.d. NMR tubes using a 180-mm Ingold 405 M3 combination microelectrode. For D2O solutions the values used are the direct reading of digital pH meter (Orion Research Model 601). For analysis of the experimental pH dependence of the chemical shifts an iterative curve-fitting software was used. [Pg.247]

The measured impedance amplitude and phase can be used to approximate the electrode model. This can be either done by using curve fitting softwares or by applying analytical methods. Consider for example the previously mentioned Randles model of Fig. 3.2. The total impedance (Z) of this model is equal to ... [Pg.39]

As stated before, another method to experimentally determine the electrode model is to perform impedance spectroscopy by a potentiostat and curve fit the resulting diagrams through a curve-fitting software like ZView 2 ( 2005 Scribner Associates, Inc.) to get the model which fits best the impedance spectrum measured. This approach was used to extract the electrode model of the disk iridium electrodes on a microelectrode array (MEA) as shown in Fig. 8.2. These electrodes could be accessed individually and had a diameter of 30p,m each. As mentioned before. [Pg.73]

The summation runs over all the absorption bands (with wavenumber Vq and experimental dipole strength Oexp) which contribute to the complex band structure. Y, D xp total dipole strength of the complex band. In practice, v is determined by curve-fitting software by placing a line shape function under the complex band. Vq is equal to the sum of the peak maxima Vq weighted by the fractional contribution Xj (0 1, X, x,- = 1)... [Pg.217]


See other pages where Curve-fitting software is mentioned: [Pg.140]    [Pg.203]    [Pg.114]    [Pg.605]    [Pg.186]    [Pg.330]    [Pg.313]    [Pg.80]    [Pg.175]    [Pg.62]    [Pg.333]    [Pg.246]    [Pg.126]    [Pg.125]    [Pg.230]    [Pg.691]    [Pg.112]    [Pg.898]    [Pg.142]    [Pg.203]    [Pg.98]    [Pg.277]    [Pg.105]    [Pg.98]    [Pg.241]    [Pg.248]    [Pg.120]    [Pg.16]    [Pg.25]    [Pg.154]   
See also in sourсe #XX -- [ Pg.313 ]




SEARCH



Curve fitting

© 2024 chempedia.info