Corona discharge method

Methods such as corona treatment have not been very common for three-dimensional moldings in Europe due to the difficulties to control parameters like distance of the corona electrode to the surface to be treated. However, simply shaped parts like side protection moldings have been effectively tteated prior to coating using the corona discharge method. A variation of the improved method is known as Ambient Pressure Plasma (Plasma Gun) (13). Ultraviolet (UV) primers have been used in France and Italy combining the adhesion effect of adhesion promoters with the attack of free radicals formed under UV irradiation to the polymer (14). [Pg.326]

Electrical methods of mineral separation are described by Olofinskii [1953] and by Rost [1956], and an account of the development of the electrostatic method has been given by Johnson [1938a, b]. This depends on the differences in the electrostatic charges acquired by mineral grains as a result of their different conductivities. In the corona discharge method, the mineral grains are electrically charged by a corona field as they are poured onto the upper... [Pg.463]

Other Polymerization Methods. Although none has achieved commercial success, there are a number of experimental alternatives to clay-catalyzed or thermal oligomeriza tion of dimer acids. These iaclude the use of peroxides (69), hydrogen fluoride (70), a sulfonic acid ion-exchange resia (71), and corona discharge (72) (see Initiators). [Pg.115]

Cl is an efficient, and relatively mild, method of ionization which takes place at a relatively high pressure, when compared to other methods of ionization used in mass spectrometry. The kinetics of the ion-molecule reactions involved would suggest that ultimate sensitivity should be obtained when ionization takes place at atmospheric pressure. It is not possible, however, to use the conventional source of electrons, a heated metallic filament, to effect the initial ionization of a reagent gas at such pressures, and an alternative, such as Ni, a emitter, or a corona discharge, must be employed. The corona discharge is used in commercially available APCI systems as it gives greater sensitivity and is less hazardous than the alternative. [Pg.181]

Particles become positively charged by a corona discharge and travel out of the charging chamber and collect on a substrate such as a microscope slide. Thus, the method is useful for particles which are to be examined by optical or electron microscopy. [Pg.313]

APPI and corona discharge-APCI methods were compared [164], A review of photoionisation and photodissociation methods in MS has appeared [165]. [Pg.386]

An ion mobility spectrometer consists of a sample-introduction device a drift tube where ionisation and separation of ions takes place and a detector. Ionisation sources of choice include radioactive sources (e.g. a 63Ni foil), photoionisation methods, corona-spray ionisation, flame ionisation and corona discharge. The most common detection method used to measure the... [Pg.415]

The significant enhancement of ion formation by a corona discharge as compared to a Ni source has already been implemented in early API sources. [139,140] The nature of the APCI plasma varies widely as both solvent and nebulizing gas contribute to the composition of the Cl plasma, i.e., APCI spectra can resemble PICI, CECI, NICI, or EC spectra (Chap. 7.2-7.4) depending on the actual conditions and ion polarity. This explains why APCI conditions suffer from comparatively low reproducibility as compared to other ionization methods. [Pg.466]

Various mass spectrometer configurations have been used for the detection of explosives, such as ion traps, quadrupoles and time-of flight mass analyzers and combinations as MS/MS systems. The ionization method is usually APCI with corona discharge [24, 25]. An example is given in Figure 20, which shows the schematic diagram of an explosive mass spectrometer detector [25]. It is based on an ion trap mass analyzer, an APCI source with corona discharge and a counter-flow introduction (CFI) system. The direction of the sample gas flow introduced into the ion source is opposite to that of the ion flow produced by the ion source. [Pg.166]

Atmospheric pressure chemical ionization APCI is a method closely related to electrospray ionization. It uses ion-molecule reactions to produce ions from analyte molecules. The sample is electrohydrodynamically sprayed into the source (Figure 14.3). The evaporation of the solvent is often supported by a heated gas at temperatures between 80 and 400°C. Within the source, a plasma is created using a corona discharge needle that is placed close to the end of the metal capillary. In this plasma, proton transfer reactions occur, leading to the ionization of the analyte, mainly by the formation of [M+H]+ ions. Compared to ESI MS, APCI MS is very well suited for the analysis of less-polar components and can therefore... [Pg.375]


See other pages where Corona discharge method is mentioned: [Pg.160]    [Pg.492]    [Pg.382]    [Pg.422]    [Pg.255]    [Pg.15]    [Pg.125]    [Pg.82]    [Pg.116]    [Pg.167]    [Pg.451]    [Pg.135]    [Pg.87]    [Pg.160]    [Pg.492]    [Pg.382]    [Pg.422]    [Pg.255]    [Pg.15]    [Pg.125]    [Pg.82]    [Pg.116]    [Pg.167]    [Pg.451]    [Pg.135]    [Pg.87]    [Pg.283]    [Pg.379]    [Pg.414]    [Pg.348]    [Pg.317]    [Pg.519]    [Pg.45]    [Pg.386]    [Pg.409]    [Pg.309]    [Pg.248]    [Pg.793]    [Pg.168]    [Pg.123]    [Pg.320]    [Pg.499]    [Pg.156]    [Pg.248]    [Pg.183]    [Pg.20]    [Pg.60]    [Pg.187]    [Pg.187]    [Pg.240]    [Pg.249]    [Pg.695]    [Pg.562]   
See also in sourсe #XX -- [ Pg.451 ]




SEARCH



Corona

Corona Method

© 2024 chempedia.info