ASTM B368, Std. Methodfor Copper-Accelerated Acetic Acid Salt Spray (Fog) Testing (CASS Test), American Society for Testing and Materials, Philadelphia, Pa., 1990. [Pg.166]

The addition of acetic acid to the salt solution used in the salt spray tests was introduced first in 1945 and is currently Annex A1 of ASTM G 85 [Practice for Modified Salt Spray (Fog) Testing]. The acidified test is much more corrosive than the normal salt spray test and is capable of producing a pattern of attack similar to that developed in outdoor service for decorative chromium plate on steel or zinc. It is much slower than the copper-accelerated acetic acid-salt spray (CASS) test in ASTM B 368 [Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test)], [77] which resembles it in effect. [Pg.571]

The most widely used cabinet test is the neutral salt spray (Fog) test (ASTM B 117), which consists of a fog of 5 % sodium chloride within the chamber at 35 C [46. Controversy exists over the validity of B 117 as a performance test because corrosion mechanisms are not always the same as those observed in automobile service. Also, not all materials can be successfully evaluated in the test. However, the value of the salt spray test as a quality assurance test is well documented [46]. Several modifications to the salt spray test have been developed including acetic acid salt spray (ASTM G 85, Annex 1), copper accelerated acetic acid salt spray (ASTM B 368), acidified synthetic seawater fog (ASTM G 43, Method of Acidified Synthetic Seawater (Fog) Testing), and modified salt spray (ASTM G 85). ASTM G 85 also includes cyclic tests. [Pg.680]

Applicable test methods include [28] Continuous Salt Spray Tests (ASTM B 117), Neutral Salt Spray Test (ASTM B 117), Acetic Acid Salt Spray Test, Copper-Accelerated Salt Spray Test (CASS) (ASTM B 368), Cyclic Salt Spray Tests, the Copper Development Association (CDA) Test, the Hitachi Salt Spray Test, Climate Tests, The Humidity Test, The International Electrotechnical Commission/Intemational Organization for Standardization (lEC/ISO) Test and Mud Test. [Pg.577]


See other pages where Copper-accelerated acetic acid-salt spray testing ASTM is mentioned: [Pg.1023]    [Pg.1052]    [Pg.1023]    [Pg.1052]    [Pg.660]    [Pg.694]    [Pg.39]    [Pg.1026]    [Pg.1055]   
See also in sourсe #XX -- [ Pg.368 , Pg.452 ]




SEARCH



ASTM

ASTM tests

Accelerated testing

Acetic acid salt spray

Acetic acid tests)

Acetic acid-salt-spray test

Acid-acceleration

Acidic accelerators

Copper acetate—

Copper salts

Copper tests

Copper-accelerated acetic acid-salt spray

Copper-accelerated acetic acid-salt spray (ASTM

Salt-spray test (ASTM

Salt-spray testing

Sprays, copper

Test, testing salt spray

© 2024 chempedia.info