Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Confirmation limits

A number of examples of limiting kinetics have been reported for reactions of [2Fe-2S] and 2[4Fe-4S] ferredoxins with inorganic complexes (11). Recent stopped-flow work has not however confirmed limiting kinetics for the reaction of azurin, ACu(I) +... [Pg.176]

The larger weight fraction of material found in the secondary wall, confirming limited previous reports [157,158]... [Pg.43]

For the analysis of spectinomycin in milk [56], acid protein precipitation and analyte extraction was combined with SPE, ion-pair LC with HFBA as ion-pair agent, and multi-stage ESI-MS-MS on an ion-trap instalment. [M+H+HjO] at m/z 351 was fragmented to yield [M+H] at m/z 333 in the first stage of MS-MS and further fragmentation of [M+H] in a second stage of MS-MS. The estimated confirmation limit for spectinomycin was 100 pg/kg milk. Further improvement of this method, especially with respect to variability of the ion-trap performance, is required to meet regulatoiy demands. [Pg.393]

Limit cycles in networks of dimension as small as four can be surprisingly long and complicated, even when the focal point coordinates are all 1. For example, the network with logical structure depicted in Fig. 4 has an asymptotically stable hmit cycle in which 174 switches take place before the cycle repeats. Projections of the phase portrait of this limit cycle attractor are shown in Fig. 5. The existence and stability of this limit cycle were confirmed analytically by the methods outlined above. We have found four-dimensional networks with confirmed limit cycles involving as many as 252 switches before repeating. Gedeon [48] has constructed four-dimensional networks with focal point coordinates tuned so that limit cycles of arbitrary length can be obtained. [Pg.163]

An additional elementary step must be added to equations (1) - (4) and (6) to account for the surface reaction of the 1-butene. Numerical simulations with an elementary step modeling approach discussed elsewhere, Cutlip (Jl ), have confirmed limit cycles for this group of elementary steps when combined with dynamic material balance equations for the reactor. We are continuing experimental and modeling investigations on these interesting phenomena. [Pg.485]

In general, it seems easier to reveal extensive disease excluding surgical treatment than to confirm limited malignant disease still suitable for resection. [Pg.301]

Note that while the ToF information is relatively consistent, the amplitude is varying considerably between the measurement points. This confirms the uncertainty related to the amplitude information which, in this works serves only to locate the area in which the measurements should be taken typically measurements are limited to within the range of signal amplitudes in excess of 30% of the peak value. [Pg.168]

In Dynamic Spatial Reconstructor at the expense of use 2D matrix of detectors there was the opportunity to use a divergent cone beam of source emission. This system had a number of lacks. In particular the number of projections is rigidly limited by the number of x-ray sources. The dispersion of source emission results in errors of data collected.. However the system confirmed basic advantages of application of conic beams and 2D matrices of detectors for collecting information about 3D object. [Pg.217]

After having proved the principles a dynamic test facility has been constructed. In this facility it is possible to inject 3 tracers in a flownng liquid consisting of air, oil and water. By changing the relative amounts of the different components it is possible to explore the phase diagram and asses the limits for the measurement principle. Experiments have confirmed the accuracy in parameter estimation to be below 10%, which is considered quite satisfactorily for practical applications. The method will be tested on site at an offshore installation this summer. [Pg.1057]

The existence of the XeCHg [34176-86-8] cation has been estabtished ia the gas phase. The Xe—C bond energy of the XeCHg cation has been estimated to be 180 A 33 kJ/mol (112) and more recently, 231 A 10 kJ/mol (113) by ion cyclotron resonance. The compound Xe(CF3)2 [72599-34-9] is reported to be a waxy white sotid having a half-life of ca 30 min at room temperature (114). The synthesis iavolved the addition of XeF2 to a tritiuoromethyl plasma, but the characterization of this compound is limited and has not been iadependently confirmed. [Pg.24]

Sohd materials, such as gilsonite and asphalt, and partially soluble sulfonated asphalt may also be added to plug small fractures in exposed shale surfaces and thereby limit water entry into the formation (105,124). The asphalts are oxidized or treated to impart partial solubiUty. These materials may be softened by the downhole temperature, causing them to deform and squeeze into small openings exposed to the borehole. Laboratory tests designed to evaluate shale-stabilizing muds have confirmed the beneficial action of these materials (125) (see also Soil STABILIZATION). [Pg.182]

Styrene is Hsted in the U.S. Toxic Substance Control Act (TSCA) Inventory of Chemicals. It is not confirmed as a carcinogen but is considered a suspect carcinogen. The recommended exposure limits are OSHA PEL 50 ppm, ACGIH TLV 50 ppm. For higher concentrations,... [Pg.487]

Some limited, volume of tiaffic also may be subject to ceitain rates, terms, and conditions collectively established by a group of carriers pursuant to an agreement between such carriers, if approved and exempted from the antitmst laws by the Surface Transportation Board (STB) (8). Whenever any rate arranged between a shipper and carrier iacorporates provisions of such an agreement, a shipper should request confirmation from the carrier that the carrier is a party to the agreement. [Pg.257]

Hydroxides. The hydrolysis of uranium has been recendy reviewed (154,165,166), yet as noted in these compilations, studies are ongoing to continue identifying all of the numerous solution species and soHd phases. The very hard uranium(IV) ion hydrolyzes even in fairly strong acid (- 0.1 Af) and the hydrolysis is compHcated by the precipitation of insoluble hydroxides or oxides. There is reasonably good experimental evidence for the formation of the initial hydrolysis product, U(OH) " however, there is no direct evidence for other hydrolysis products such as U(OH) " 2> U(OH)" 2> U(OH)4 (or UO2 2H20). There are substantial amounts of data, particulady from solubiUty experiments, which are consistent with the neutral species U(OH)4 (154,167). It is unknown whether this species is monomeric or polymeric. A new study under reducing conditions in NaCl solution confirms its importance and reports that it is monomeric (168). 8olubihty studies indicate that the anionic species U(OH) , if it exists, is only of minor importance (169). There is limited evidence for polymeric species such as Ug(OH) " 25 (1 4). [Pg.326]

Although it has been reported (138) that decolorization of wastewater containing reactive azo dyes with sodium hydrosulfite is possible only to a limited extent, others have demonstrated good reduction (decolorization). For example, using zinc hydrosulfite for the decolorization of dyed paper stock (139) resulted in color reduction of 98% for azo direct dyes (139). A Japanese patent (140) describes reducing an azo reactive dye such as Reactive Yellow 3 with sodium hydrosulfite into its respective aromatic amines which ate more readily adsorbable on carbon than the dye itself. This report has been confirmed with azo acid, direct, and reactive dyes (22). [Pg.382]

At X-ray fluorescence analysis (XRF) of samples of the limited weight is perspective to prepare for specimens as polymeric films on a basis of methylcellulose [1]. By the example of definition of heavy metals in film specimens have studied dependence of intensity of X-ray radiation from their chemical compound, surface density (P ) and the size (D) particles of the powder introduced to polymer. Have theoretically established, that the basic source of an error of results XRF is dependence of intensity (F) analytical lines of determined elements from a specimen. Thus the best account of variations P provides a method of the internal standard at change P from 2 up to 6 mg/sm the coefficient of variation describing an error of definition Mo, Zn, Cu, Co, Fe and Mn in a method of the direct external standard, reaches 40 %, and at use of a method of the internal standard (an element of comparison Ga) value does not exceed 2,2 %. Experiment within the limits of a casual error (V changes from 2,9 up to 7,4 %) has confirmed theoretical conclusions. [Pg.104]

The results of simulation have been confirmed by determination of Fe traces in quai tz sand, Cu and Mo in flotation tails and Ag in waste fixing waters on BRA-17-02 analyzer based on X-ray gas-filled electroluminescent detector and on BRA-18 analyzer based on Si-drift detector. The results of the simulation conform satisfactory with the experimental data in the mentioned cases the optimum filtration results in 2 to 5 times lowering of the detection limit. [Pg.134]

The experimental studies of a large number of low-temperature solid-phase reactions undertaken by many groups in 70s and 80s have confirmed the two basic consequences of the Goldanskii model, the existence of the low-temperature limit and the cross-over temperature. The aforementioned difference between quantum-chemical and classical reactions has also been established, namely, the values of k turned out to vary over many orders of magnitude even for reactions with similar values of Vq and hence with similar Arrhenius dependence. For illustration, fig. 1 presents a number of typical experimental examples of k T) dependence. [Pg.5]

It is important to emphasize that GDMS provides an essentially complete elemental impurity survey to very low detection limits in a timely, cost effective manner. Although this level of analysis requires long signal integration times, the Ga measurement requires only a few hours to obtain an accurate, confirmed analysis to 7N levels. Except for the presence of rather high In in the Ga, the remaining impurities are at sub ppmw levels. Detection limits in the Ga are clearly adequate for 7N qualification. [Pg.617]


See other pages where Confirmation limits is mentioned: [Pg.170]    [Pg.170]    [Pg.28]    [Pg.507]    [Pg.717]    [Pg.185]    [Pg.155]    [Pg.71]    [Pg.260]    [Pg.44]    [Pg.52]    [Pg.60]    [Pg.108]    [Pg.124]    [Pg.288]    [Pg.166]    [Pg.412]    [Pg.474]    [Pg.423]    [Pg.293]    [Pg.276]    [Pg.200]    [Pg.1612]    [Pg.84]    [Pg.123]    [Pg.430]    [Pg.36]    [Pg.644]    [Pg.257]    [Pg.613]    [Pg.217]   
See also in sourсe #XX -- [ Pg.467 , Pg.470 ]




SEARCH



CONFIRM

Confirmation

© 2024 chempedia.info