Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Compromise condition

Often, maximum thermal operating efficiency is incompatible with optimum lime quahty. Usually this problem is resolved by operating under compromise conditions between these two extremes. [Pg.171]

Frothing Agents are intended to stabilize the particle (mineral)-air mixture (foam) at the surface of the flotation tank. Alkyl or amyl alcohols in the C5 to C12 range are typical frothers. They lower ysv which is beneficial to the stability of the foam to some extent collectors and frothers may counteract in their effects so that compromise conditions must be selected. [Pg.280]

Problems of environmental pollution by particulate emissions as a part of the complex complicated palette of environmental analytical problems will be covered in the centre of this section. Airborne particulates and their composition are affected by manifold influences. The main influences shall be ascertained. The power and the limits of multivariate statistics when applied to environmental problems under the compromising conditions of routine monitoring shall also be demonstrated. [Pg.251]

Commonly the compromising conditions of routine environmental monitoring lead to restrictions on the accuracy and the precision of sampling and analysis. The purpose of this section is to show that under these conditions multivariate statistical methods are a useful tool for qualitative extraction of new information about the degree of stress of the investigated areas, and for identification of emission sources and their seasonal variations. The results represented from investigation of the impact of particulate emissions can, in principle, be transferred to other environmental analytical problems, as described in the following case studies. [Pg.269]

Although operation in a single pot has many advantages, it may prove intractable to alter the biocatalyst to perfectly match the chemical environment. In such cases a compromise may need to be reached such that neither the chemical or biocatalytic operations are operating optimally but under a compromised condition. Such conditions must still prove beneficial in relation to operation in separate reactors, each under optimal conditions. [Pg.422]

Comparisons of results. Experiments were carried out to evaluate effects of compromise conditions on sensitivities of the elements in the two groups discussed earlier. Near optimum conditions were established for each element determined individually, and the sensitivity of that element under the optimum conditions is compared with the sensitivity obtained with compromise conditions used for multielement determinations. Results are presented in Table X for these comparisons. [Pg.87]

A computer program, MacSimion, [92] can be used to model the ion trajectories in ion optics after various assumptions. From these considerations it becomes clear that when dealing with several elements any optimization will also lead to compromises. Thus there will always be a difference in performance in mass spectrometry with respect to sensitivity and to the lowest matrix influences between single-element optimization and compromise conditions. [Pg.84]

In order to obtain the optimum power of detection, the analyte density in the plasma, the ionization and the ion transmission must be maximized. The power will thus be between 0.6 and 2 kW and the sampler at about 10-15 mm above the tip of the injector. The detection limits, obtained at single element optimum conditions differ considerably from those at compromise conditions, but are still significantly lower than in ICP-AES (Table 17). In general it can be said that for the heavy elements, which have complex atomic term schemes and accordingly very... [Pg.263]

II Compromise conditions for simultaneous multielement analyses, Spectrochim Acta, Part B 30 309—334. [Pg.319]

MHz and 50 MHz ICPs, and various spectrometer characteristics and settings such as monochromator, polychromator with compromise conditions, high resolution) Stoeppler (1991) (data are reported to have been converted to 3 s and are for the most sensitive lines with a 50 MHz conventional Ar ICP spectrometer) Ihnat (1984) (typical good DLs for elements in aqueous solution at typically the most detective lines reflecting both calculated and measured values) Broekaert (1994) Thompson and Walsh (1989). [Pg.1551]

Data for ICPAES(USN) are from Boumans (1987b) (DLs, on a 2 basis, are for conventional Ar ICPs operating under compromise conditions with ultrasonic nebulization and include monochromator and combination monochromator/polychromator spectrometers. [Pg.1551]

Fifth, are we dealing with conditions optimized for a single element or multielement analysis Compromise conditions degrade detection limits but Improve the Informing power of the method (l.e., the total amount of Information about a sample that can be obtained from an analytical method). [Pg.115]

Since AAS is classically a single-element technique, there is an increasing trend to overcome this Hmitation by the development of simultaneous multi-element spectrometers with multichannel detection. Such instmments are presently available on the market, and allow the simultaneous determination of up to six elements. As these are GF instruments, they must however be used under compromise conditions for the ashing and atomisation steps. [Pg.470]

It is highly likely that genes conveying disease resistance or compromised conditions tolerance have existed in plants in the wild or in subsistence agriculture. These genes are rapidly being lost as less productive crops are being replaced by more productive crops under intense... [Pg.243]

Each compound has an optimal reaction path to complete derivatization, although where a mixture is concerned it may be hard to reconcile the various different optimal reaction paths, and compromise conditions will have to be chosen. But time spent in playing about with the parameters of temperature, time, reagent concentrations, solvents and catalysts is time well spent, because it will eventually save time in running the subsequent analyses—over and over again. Besides, it also makes the final report more professional-looking and convincing I... [Pg.10]

GAs are produced when the nitrogen source has been exhausted []i.e. after bikaverin (Fig. 1) synthesis]. The best compromise conditions to obtain a high mycelial mass which pigments within a... [Pg.28]

An alternative way to achieve atomization under temporally isothermal conditions is to place the sample on a graphite probe (see Figure 3). The probe is removed from the tube prior to the atomization stage, and then reintroduced once the tube has reached the set temperature. This system is more complex than the platform, and requires the presence of an additional aperture in the tube, which reduces sensitivity. The use of platforms and probes is very efficient in reducing interference effects, but suffers from the disadvantage that the processes of vaporization and atomization are coupled, which may sometimes require compromise conditions. [Pg.182]


See other pages where Compromise condition is mentioned: [Pg.15]    [Pg.488]    [Pg.93]    [Pg.342]    [Pg.117]    [Pg.334]    [Pg.371]    [Pg.284]    [Pg.104]    [Pg.112]    [Pg.651]    [Pg.361]    [Pg.88]    [Pg.218]    [Pg.223]    [Pg.262]    [Pg.401]    [Pg.218]    [Pg.328]    [Pg.106]    [Pg.84]    [Pg.280]    [Pg.301]    [Pg.5187]    [Pg.458]    [Pg.88]    [Pg.218]    [Pg.223]    [Pg.262]   
See also in sourсe #XX -- [ Pg.223 ]

See also in sourсe #XX -- [ Pg.223 ]

See also in sourсe #XX -- [ Pg.293 ]




SEARCH



Compromises

© 2024 chempedia.info