Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Column Raschig rings

Fig. 21. Random packing elements for distillation columns (a), Raschig ring (metal) (b). Bed saddle (ceramic) (c), Intalox saddle (ceramic) (d), PaH ring... Fig. 21. Random packing elements for distillation columns (a), Raschig ring (metal) (b). Bed saddle (ceramic) (c), Intalox saddle (ceramic) (d), PaH ring...
FIG. 15 53 Effect of pulsing on extraction in a packed column methyl isobutyl ketone-acetic acid-water (continuous). Tower diameter = 1.58 in, 27-in depth of V4-in Raschig rings. = Vc = 7.5 to 10. To convert inches to centimeters, multiply by 2.54. [Data of Chanhy, von Berg, and Wiegandt, Ind. Eng. Chem., 47, 1153 (1.9.55), with permission. ... [Pg.1489]

Many operating data for carbonate plants are cited by Kohl and Riesenfeld (Gn.s Purification, Gulf, 1985) but not including tower heights. Pilot plant tests, however, are reported on 0.10- and 0.15-m (4- and 6-in) columns packed to depths of 9.14 m (30 ft) of Raschig rings hy Benson et al. (Chem. Eng. Prog., 50, 356 [1954]). [Pg.2110]

Lower pressure drop (less than half) than Raschig rings, also lower HTU (in some systems also lower than Bert saddles), higher flooding limit. Good liquid distribution, high capacity. Considerable side thmst on column wall. Available in metal, plastic and ceramic. [Pg.86]

Kramers and Alberda (K20) have reported some data in graphical form for the residence-time distribution of water with countercurrent air flow in a column of 15-cm diameter and 66-cm height packed with 10-mm Raschig rings. It was concluded that axial mixing increased with increasing gas flow rate and decreasing liquid flow rate, and that the results were not adequately represented by the diffusion model. [Pg.96]

Hoogendoorn and Lips (H10) carried out residence-time distribution experiments for countercurrent trickle flow in a column of 1.33-ft diameter and 5- and 10-ft height packed with -in. porcelain Raschig rings. The fluid media were air and water, and ammonium chloride was used as tracer. The total liquid holdup was calculated from the mean residence time as found... [Pg.99]

Larkins et al. (L2) visually observed flow patterns and measured pressure drop and liquid holdup for cocurrent downflow of gas and liquid through beds of spheres, cylinders, and Raschig rings of diameters from 3 mm to f in. in experimental columns of 2- and 4-in. diameter, as well as in a commercial unit several feet in diameter. The fluid media were air, carbon dioxide, or natural gas and water, water containing methylcellulose, water containing soap, ethylene glycol, kerosene, lubricating oil, or hexane. [Pg.101]

Stemerding (S16) has reported dispersion measurements in a column filled with 13-mm Raschig rings with water and air in countercurrent flow. The dispersion coefficient was observed to be essentially independent of the water flow rate and dependent on the air flow rate only. For increasing air flow rates, the dispersion coefficient passed through a maximum. [Pg.106]

Raschig rings are cheaper per unit volume than Pall rings or saddles but are less efficient, and the total cost of the column will usually be higher if Raschig rings are specified. For new columns, the choice will normally be between Pall rings and Berl or Intalox saddles. [Pg.592]

Two heat-sensitive organic liquids of an average molecular mass of 155 kg/kmol are to be separated by vacuum distillation in a 100 mm diameter column packed with 6 mm stoneware Raschig rings. The number of theoretical plates required is 16 and it has been found that the HETP is 150 mm. If the product rate is 5 g/s at a reflux ratio of 8, calculate the pressure in the condenser so that the temperature in the still does not exceed 395 K (equivalent to a pressure of 8 kN/m2). It may be assumed that a = 800 m2/m3, /x = 0.02 mN s/m2, e = 0.72 and that the temperature changes and the correction for liquid flow may be neglected. [Pg.47]

A column 0.6 m diameter and 4 m high is, packed with 25 mm ceramic Raschig rings and used in a gas absorption process carried out at 101.3 kN/m2 and 293 K. If the liquid and gas properties approximate to those of water and air respectively and their flowrates are 2.5 and 0.6 kg/m2s, what is the pressure drop across the column In making calculations, Carman s method should be used. By how much may the liquid flow rate be increased before the column floods ... [Pg.47]

A packed column, 1.2 m in diameter and 9 m tall, is packed with 25 mm Raschig rings, and used for the vacuum distillation of a mixture of isomers of molecular mass 155 kg/kmol. The mean temperature is 373 K, the pressure at the top of the column is maintained at 0.13 kN/m2 and the still pressure is 1.3-3.3 kN/m2. Obtain an expression for the pressure drop on the assumption that this is not appreciably affected by the liquid flow and may be calculated using a modified form of Carman s equation. Show that, over the range of operating pressures used, the pressure drop is approximately directly proportional to the mass rate of flow rate of vapour, and calculate the pressure drop at a vapour rate of 0.125 kg/m2. The specific surface of packing, S = 190 m2/m3, the mean voidage of bed, e = 0.71, the viscosity of vapour, // = 0.018 mN s/m2 and the molecular volume = 22.4 m3/kmol. [Pg.48]

A packed column, 1.22 m in diameter and 9 m high, and packed with 25 mm Raschig rings, is used for the vacuum distillation of a mixture of isomers of molecular mass 155 kg/kmol. The mean temperature is 373 K, the pressure at the top of the column is maintained at 0.13 kN/m2, and the still pressure is 1.3 kN/m2. Obtain an expression for... [Pg.49]

The ether is removed by distillation on a steam bath through a column filled with Raschig rings. The yellowish crystalline residue is treated with 150 g. of ice and 150 g. (130 ml.) of 102V hydrochloric acid, and the solution is evaporated to dryness under reduced pressure (Note 7). The crystalline residue is dissolved in the minimum amount of hot water (about 70 ml.), and boiling isopropyl alcohol (about 1.5 1.) is added until crystalline 3-quinuclidone hydrochloride begins to separate. The mixture is cooled to 0-5°, and the solid is separated by filtration, washed with acetone, and dried. The yield of 3-quinuclidone hydrochloride, m.p. 294-296° (sealed capillary) (Note 8), is 102-109 g. (77-82%). [Pg.45]


See other pages where Column Raschig rings is mentioned: [Pg.402]    [Pg.402]    [Pg.96]    [Pg.97]    [Pg.218]    [Pg.171]    [Pg.171]    [Pg.173]    [Pg.1394]    [Pg.364]    [Pg.304]    [Pg.247]    [Pg.253]    [Pg.130]    [Pg.53]    [Pg.92]    [Pg.92]    [Pg.93]    [Pg.95]    [Pg.97]    [Pg.98]    [Pg.102]    [Pg.106]    [Pg.107]    [Pg.213]    [Pg.96]    [Pg.97]    [Pg.218]    [Pg.599]    [Pg.614]    [Pg.410]    [Pg.283]    [Pg.317]    [Pg.19]    [Pg.216]   
See also in sourсe #XX -- [ Pg.93 ]




SEARCH



Column packings Raschig rings

Raschig

Raschig rings

© 2024 chempedia.info