Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chromatography integration

CO Dasenbrock, WR Lacourse. Assay for cephapirin and ampicillin in raw milk by high-performance liquid chromatography-integrated pulsed amperometric detection. Anal Chem 70 2415-2420,1998. [Pg.685]

Finally, we have detected an ESR signal with g = 2.0019 and a derivative peak-to-peak line width of 1.9 G at 296 K in solid samples before chromatography. Integrated absorption plots indicate about 1 electron spin/1000 C o units. This signal may... [Pg.85]

Schafer, C. Lubda, D. Alkyl Diol Silica Restricted Access Pre-Column Packings for Fast Liquid Chromatography-Integrated Sample Preparation of Biological Fluids, J. Chromatogr. A 909,73-78 (2001). [Pg.510]

Recently, using glass micro structures for electroosmotically driven liquid chromatography was reported [48], as well as using multichannel array thin-layer chromatography with diffuse reflectance infrared spectroscopy detection [49]. Open-tubular liquid chromatography integrated onto silicon has been successfiil [50]. [Pg.18]

A description of the preparatory steps before chromatography is performed from an integral part of the complete documentation. A record is necessary of the... [Pg.119]

In any form of analysis it is important to determine the integrity of the system and confirm that artefacts are not produced as a by-product of the analytical procedure. This is particularly important in enantiomeric analysis, where problems such as the degradation of lactone and furanon species in transfer lines has been reported (40). As chromatography unions, injectors, splitters, etc. become more stable and greater degrees of deactivation are possible, problems of this kind will hopefully be reduced. Some species, however, such as methyl butenol generated from natural emissions, still remain a problem, undergoing dehydration to yield isoprene on some GC columns. [Pg.65]

Ethanol concentration in the fermentation broth is determined by using gas chromatography (HP 5890 series II with HP Chemstation data processing software, Hewlett-Packard, Avondale, PA) with a Poropak Q Column, and a Hewlett-Packard model 3380A integrator. A flame ionisation detector (FID) is used to determine ethanol. The oven temperature is maintained at 180 °C, and the injector and detector temperature are maintained at 240 °C. The sample taken from the fermentation media has to be filtered and any internal standard must be added for analysis based on internal standard methods otherwise, the area under the peak must be compared with known standard samples for calculation based on external standard methods. [Pg.257]


See other pages where Chromatography integration is mentioned: [Pg.304]    [Pg.399]    [Pg.21]    [Pg.132]    [Pg.388]    [Pg.404]    [Pg.409]    [Pg.439]    [Pg.263]    [Pg.114]    [Pg.356]    [Pg.304]    [Pg.399]    [Pg.21]    [Pg.132]    [Pg.388]    [Pg.404]    [Pg.409]    [Pg.439]    [Pg.263]    [Pg.114]    [Pg.356]    [Pg.408]    [Pg.419]    [Pg.420]    [Pg.429]    [Pg.105]    [Pg.105]    [Pg.2205]    [Pg.446]    [Pg.79]    [Pg.5]    [Pg.327]    [Pg.167]    [Pg.250]    [Pg.251]    [Pg.378]    [Pg.379]    [Pg.201]    [Pg.424]    [Pg.229]    [Pg.246]    [Pg.121]    [Pg.471]    [Pg.730]    [Pg.1013]    [Pg.395]    [Pg.405]    [Pg.26]    [Pg.37]   
See also in sourсe #XX -- [ Pg.64 ]




SEARCH



© 2024 chempedia.info