Chromatographic performance viscosity

Thus far, SPME methods have had only limited success in isolating polar organics (e.g., chlorophenols [30] and formaldehyde [31]) or ions [32,33] from aqueous mixtures. However, the tunable hydrophobicity and multimodal potential interaction chemistries of ILs suggest potential applications in LPME. Further, their high viscosity coupled with their minimal vapor pressure promotes stable droplet formation. Figure 5.2 illustrates the experimental setup for LPME. In addition, analyte recovery can be performed simply by injecting the droplet onto a liquid chromatographic column. [Pg.171]

The following table gives the properties of common gas chromatographic carrier gases. These properties are those used most often in designing separation and optimizing detector performance. The density values are determined at CPC and 0.101 MPa (760 torr).1 The thermal conductivity values, X, are determined at 48.9°C (120°F).1 The viscosity values are determined at the temperatures listed and at 0.101 MPa (760 torr).1 The heat capacity (constant pressure) values are determined at 15°C and 0.101 MPa (750 torr).2... [Pg.10]

The speed of a chromatographic separation is fixed by the particle size, the stationary phase characteristics, the available pressure, the solvent viscosity, the solute diffusivity, the a values of the critical pair, and extracolumn dispersion. One way to achieve faster separations is to reduce the particle size of the stationary phase. However, if material of smaller diameter is packed into a conventional size column, the backpressure will become prohibitively high. Thus, in a compromise between speed and optimum performance, narrow (<2 mm) columns packed with small 3-5 ju.m diameter particles have been developed. [Pg.245]

Size exclusion chromatographic analyses in tetrahydrofuran were performed with a Waters 150C GPC with six p-Styragel columns having a continuous porosity range of 10 - 10 k and also with the Perkin- Elmer Model 601 HPLC with three p-Styragel columns (10 , lO", 10 A) after calibration with standard polystyrene samples. Intrinsic viscosities were measured In chloroform at 30.0 C and in tetrahydrofuran at 40°C using an Ubbelohde type viscometer. [Pg.38]

From a historical point of view, the analysis of food is performed predominandy using typical chemical or physicochemical methods. These are, for example, wet chemical methods for proximity analysis or chromatographic methods for the analysis of pesticides and veterinary dmg residues. In addition, food chemists use such physics-based methods as viscosity measurement and atomic absorption spectroscopy for the analysis of heavy metals. [Pg.498]

The permeability of a device can be determined from flow rate, viscosity, column length and pressure as outlined in Section 2.2.5. Now we have accomplished what we have set out to do we have linked the performance parameter, the speed of analysis and the pressure to each other. All performance parameters can thus be determined from externally measurable observations without reference to the internal content of the chromatographic device ... [Pg.44]


See other pages where Chromatographic performance viscosity is mentioned: [Pg.125]    [Pg.435]    [Pg.125]    [Pg.121]    [Pg.299]    [Pg.333]    [Pg.75]    [Pg.66]    [Pg.383]    [Pg.699]    [Pg.227]    [Pg.94]    [Pg.3]    [Pg.29]    [Pg.37]    [Pg.131]    [Pg.325]    [Pg.671]    [Pg.94]    [Pg.26]    [Pg.674]    [Pg.13]    [Pg.9]    [Pg.31]    [Pg.242]    [Pg.89]    [Pg.403]    [Pg.152]    [Pg.283]    [Pg.333]    [Pg.358]    [Pg.742]    [Pg.1384]    [Pg.1543]    [Pg.57]    [Pg.864]    [Pg.160]    [Pg.424]    [Pg.278]    [Pg.317]    [Pg.272]    [Pg.39]    [Pg.696]    [Pg.338]    [Pg.22]   