Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Bruceton test

T.W. Anderson et al, NAVORD Rept 65-46 (1946) described seven varieties of staircase method including the Bruceton test. Natrella (Ref 42a) also gives several References to other discussions of the up-and-down or staircase method of testing... [Pg.1080]

The Bruceton test affords a fairly good estimate of the 10, 50 and 90% firing points for minimum trials, but depends heavily on the assumption that the sample sensitivity follows a normal distribution about the median firing height... [Pg.1080]

The Bruceton test (as expected) gives a good value of the mean drop height, ie 50%... [Pg.300]

Tiffany, Physical Testing of Explosives at the Bureau of Mines Explosives Experiment Station, Bruceton, Pa , US Bureau of Mines Bull 346 (1931), 60-63 126-133... [Pg.140]

Galleries for Testing Permissible Explosives. Several refs are given in Vol 1, p XIV. European galleries and US galleries at Bruceton,... [Pg.303]

B) Drop Weight Impact Test used at LASL is a modified version of machine developed by E.H. Eyster R.F. Davis at the Explosives Research Laboratory, Bruceton, Pa and described in OSRD 5744(1945). The apparatus is known as "ERL Machine . [Pg.322]

The firing pin and the plastic holder are discarded after firing. The test procedure may follow in firing either the Bruceton or the Frankford method... [Pg.1081]

Bruceton, Pa , USBurMines, Bulletin 346, GovtPtgOff, Washington, DC(1931), pp 108-15 (Testing Detonators and Electric Detonators by Sand Test and Nail Test) ... [Pg.1103]

N. E. Hanna et al, US Bur Mines RJ No 5463 (1959) CA 53, 14517 (1959). The effect of 0, 3.6, 6.6 9.5% NaCl on the incendivity of permissible explosives was studied by the Bruceton up-and-down technique in gallery tests. The study showed that the addn of relatively small quantities of NaCl tends to reduce but does not eliminate ig-... [Pg.286]

The Bruceton method is also frequently used in other destructive tests, eg in functioning tests of detonators, gap tests for shock sensitivity, or in tests where the test alters a sample so that it is no longer in its original state... [Pg.301]

A 40mg sample is placed on a brass cap which is inverted over the anvil. The falling weight is normally 5kg. If the volume of gas evolved by a 0.03mg sample is more than 1ml, then the test is considered a go. The Bruceton method is used and results are reported as Figure of Insensitiveness or FI which is ob-... [Pg.302]

Addnl Refs A) E. Burlot, MAF 14, 303 (1935) (Exudation test) B) Explosives Research Laboratory, Bruceton, Pennsylvania, "Interim Report on the Preparation and Testing of Explosives", Division 8,... [Pg.380]

ERL impact apparatus, type 12 This test was developed by the US Army Armament Research, Development and Engineering Center and is optional for use. The machine (Bruceton Machine) Type 12 consists of a striker pin (made of hardened tool steel, ground and polished) with surface in contact... [Pg.190]

During World War II Dixon and Mood [72] developed a special experimental method for testing the sensitiveness of explosives to impact. The method gave a statistical estimation of the mean value. It became known as the Bruceton up-and-down method. The primary advantage of the method is that it increases the accuracy with which the mean value can be economically determined. The method requires fewer tests than other methods. [Pg.445]

Explosion Test at 360°— did not expl Impact Se nsitivily hy Bruceton No 3 Machine — 50% positive >90cm Power by Ballistic Mortar 137% of TNT Thermal Stability at 100° — not acid in 300 mins... [Pg.272]

If the expl submitted to the BurMines is intended to be used in gaseous and/or dusty coal mines, it shall be tested (in addition to stability) for permissibility in galleries which are located at Bruceton, Pennsylvania. A brief description of these galleries and tests is.given in Vol 3 of Encycl (Ref 13, pp C375 to C377), whereas a detailed description is found in BurMinesBull 346 (Ref 5, pp49-59)... [Pg.513]

Wm H- Rinkenbach, EXPLOSIVES Their. Materials, Constitution and Analysis , Bull 219(1923), ppll6—118(Physical examination of Blasting Explosives) 118—19 (Dope-size test) 119—43 (Chemical Analysis of Blasting Explosives) 5) C.E. Munroe J.E. Tiffany, Physical Testing of Explosives at the Bureau of Mines Experimental Station, Bruceton, Pennsylvania , USBurMines Bull 346(1931)... [Pg.543]

M. United States of America. All tests are conducted by the Bureau of Mines at Bruceton, where several galleries are located. The main,... [Pg.158]

When the Bur of Mines Explosives Experiment Station was established at Bruceton, Pa, the tests for permissible expls started to be conducted there. Right from the beginning many expls were submitted for testing but only a few passed the tests. This was because most of the submitted mixts were compounded without any consideration to oxygen balance, heat of expln (or deflagration) or max temp developed on expln. In... [Pg.229]


See other pages where Bruceton test is mentioned: [Pg.860]    [Pg.860]    [Pg.301]    [Pg.301]    [Pg.140]    [Pg.301]    [Pg.861]    [Pg.40]    [Pg.293]    [Pg.860]    [Pg.860]    [Pg.301]    [Pg.301]    [Pg.140]    [Pg.301]    [Pg.861]    [Pg.40]    [Pg.293]    [Pg.322]    [Pg.328]    [Pg.1079]    [Pg.1081]    [Pg.197]    [Pg.300]    [Pg.207]    [Pg.306]    [Pg.511]    [Pg.68]    [Pg.704]    [Pg.709]    [Pg.710]    [Pg.577]    [Pg.96]    [Pg.152]    [Pg.159]    [Pg.160]    [Pg.253]   