Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Blocked screens

Normal Pressure. Water or mud blocking. Screen plugging. Minimum filtration rate muds. Thin friable filter cakes. [Pg.704]

Maple Block Screening Method. A series of experimental procedures were performed on bonding maple block wood (Cook, P. M., Eastman Kodak at Kingsport, TN, personal communications, 1987). The procedure adopted was the ASTM D 905 standard, modified as follows Sugar maple (Acer saccharum) wood, 76 by 25 by 5.7 mm in size (3 inches long, 1 inch wide, and 0.25 inch thick), with 6% moisture content was planed to obtain fresh surfaces for bonding. The desired amount of resin (with no mix additives) was weighed (58.6 g/m2, 12 lb/1000 ft2, resin solids basis) and applied to one block surface and then a second clean block was overlapped so that 25 square mm (1 square inch) surface area common to each block was coated. The resin coated blocks were placed directly in the hot press (no clamp time). The blocks were hot pressed at 177°C (350°F) for 4 to 6 minutes at 3.44 MPa (500 psi). All bonded blocks were allowed to... [Pg.334]

Single Pore Blocking (Screening). This mechanism occurs when the particle size is close to the pore throat diameter. In this case foreign particles will block the pores, thus eliminating them from the flow system. The permeability response is... [Pg.305]

For one thing, there are subsystems connected with a composition to the ACP. The subsystem called lane is connected via an aggregation to the ACP. The components themselves are connected with a generalization to the block screening device. All detection devices have several attributes and operations they share that are expressed with the generalized component. In addition to the attributes... [Pg.1724]

PE and PP waxes are used as carriers for such pigments but it has been difficult to ensure complete avoidance of agglomerates with consequent blocking screens. [Pg.593]

With the reference block method the distance law of a model reflector is established experimentally prior to each ultrasonic test. The reference reflectors, mostly bore holes, are drilled into the reference block at different distances, e.g. ASME block. Prior to the test, the reference reflectors are scanned, and their maximised echo amplitudes are marked on the screen of the flaw detector. Finally all amplitude points are connected by a curve. This Distance Amplitude Curve (DAC) serves as the registration level and exactly shows the amplitude-over-distance behaviour" of the reference reflector for the probe in use. Also the individual characteristics of the material are automatically considered. However, this curve may only be applied for defect evaluation, in case the reference block and the test object are made of the same material and have undergone the same heat treatment. As with the DGS-Method, the value of any defect evaluation does not consider the shape and orientation of the defect. The reference block method is safe and easy to apply, and the operator need not to have a deep understanding about the theory of distance laws. [Pg.813]

The dark blue solution containing 5—10% of cellulose with a DP of 1000—2000 is filtered through a series of plate-and-frame filter presses using fine mesh metal screens to remove any particles that might block the spinneret holes. It is then deaerated under vacuum and stored ready for spinning. Unlike viscose dope, the cuprammonium cellulose [9050-09-3] solution is relatively stable. [Pg.351]

Mica splittings are processed from lower quaUty blocks and from sheets too thin for blocks and unsatisfactory for producing film. The splittings are packed for sale in three ways book form, which are laminae spHt to the desired thickness from the same book of mica, then dusted with mica dust, and restacked in book form pan packed, in which splitting layers are placed evenly in a pan, and each layer separated by a thin sheet of paper then pressed together and loose packed, in which splittings are si2ed with screens then padded loosely in a wooden box for shipment. [Pg.289]

In medical apphcations, many test procedures have been developed for screening the efficiency of fabrics to block the passage of vimses, blood-home pathogens, etc. [Pg.170]

Sensitive to toxins, in this case means that the assay presents no false negative results. Primary hepatocytes can elucidate hepatotoxins, and mouse neuroblastoma cells can elucidate sodium channel-blocking neurotoxins therefore these assays can be used to screen for the appropriate toxins. [Pg.121]

Heat build-up Replace screen with one correctly sized and/or due to too fine or clean screen blocked outlet, Install pressure indicator downstream and screen. upstream of mill for conveyed systems Measure temperature at strategic points in mill casing to detect and alarm product temperature rise CCPS G-12 CCPS G-23 CCPS G-29... [Pg.96]

Column vacuum block 35 mm Roll film camera Focussing screen Plate camera 16 cm Main screen... [Pg.100]

System designers often think dampers bloek airflow and are suitable to prevent baek drafts in idle towers. This is not the ease. Airfoil dampers simply hamper fan housing efficiency- they do not block airflow. Air Inlet Screens are always part of blow through, counterflow towers to protect people from rotating equipment. Some designs can be a hazard when accessible from the underside and require the specifier to call out additional screening. They can be a worthwhile accessory when there are nearby trees even when not required for safety reasons. Air inlet screens should be eliminated on towers utilizing inlet ductwork. Inlet ductwork may also make it necessary to block extraneous air entry such as from the underside when towers are elevated. [Pg.80]

Internal Equipment Blockage bv Collapsed Internals - Contingencies such as collapsed reactor bed vessel internals (e.g., fixed-bed reactor grids, coked catalyst beds, accumulation of catalyst fines, plugging of screens and strainers, lines blocked with sediments, etc.) should be considered to identify any overpressure situations that could result. The use of the "1.5 Times Design Pressure Rule" is applicable in such cases, if this is a remote contingency. [Pg.136]


See other pages where Blocked screens is mentioned: [Pg.44]    [Pg.272]    [Pg.478]    [Pg.479]    [Pg.272]    [Pg.304]    [Pg.124]    [Pg.361]    [Pg.44]    [Pg.272]    [Pg.478]    [Pg.479]    [Pg.272]    [Pg.304]    [Pg.124]    [Pg.361]    [Pg.541]    [Pg.1805]    [Pg.312]    [Pg.43]    [Pg.261]    [Pg.156]    [Pg.30]    [Pg.349]    [Pg.348]    [Pg.62]    [Pg.73]    [Pg.1549]    [Pg.2223]    [Pg.2385]    [Pg.363]    [Pg.364]    [Pg.553]    [Pg.136]    [Pg.155]    [Pg.1002]    [Pg.340]    [Pg.340]    [Pg.115]    [Pg.17]    [Pg.78]    [Pg.71]    [Pg.773]   