Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Basic Laboratory Measurements

As early as 1889 Walker (320), using samples of thiazole, 2,4-dimethylthiazoie, pyridine, and 2,6-dimethylpyridine obtained from Hantzsch s laboratory, measured the electrical conductivity of their chlorhydrates and compared them with those of salts of other weak bases, especially quinoline and 2-methylquinoline. He observed the following order of decreasing proton affinity (basicity) quinaldine>2,6-dimethyl-pyridine>quinoline>pyridine>2,4-dimethylthiazole> thiazole, and concluded that the replacement of a nuclear H-atom by a methyl group enhanced the basicity of the aza-aromatic substrates. [Pg.91]

This simplified calculation is used to illustrate basic computational techniques. It assumes that all of the Fe(OH)3(aq) is a true solute. The quality of this assumption is a matter of debate as at pH 8, Fe(OH)3(aq), tends to form colloids. Thus, laboratory measurements of ferrihydrite solubility yield results highly dependent on the method by which [Fe(lll)]jQ(gj is isolated. Ultrafiltration techniques that exclude colloids from the [Fe(lll)]jQjgj pool produce very low equilibrium solubility concentrations, on the order of 0.01 nM. This is an important issue because a significant fraction of the iron in seawater is likely colloidal, some of which is inorganic and some organic. In oxic... [Pg.132]

However, even if such measurements were possible, would the uncertainty of the result be small enough to establish that production does indeed balance observed loss of ozone The calculation of ozone loss in the Antarctic ozone hole was shown to have an uncertainty of 35 to 50%. The uncertainty for analyzing whether production balances loss in the midlatitude stratosphere is similarly 35 to 50%. About half of the uncertainty is in the measurements of stratospheric abundances, which are typically 5 to 35%, and half is in the kinetic rate constants, which are typically 10 to 20% for the rate constants near room temperature but are even larger for rate constants with temperature dependencies that must be extrapolated for stratospheric conditions below the range of laboratory measurements. In addition to uncertainties in the photochemical rate constants, there are those associated with possible missing chemistry, such as excited-state chemistry, and the effects of transport processes that operate on the same time scales as the photochemistry. Thus, simultaneous measurements, even with relatively large uncertainties, can be useful tests of our basic understanding but perhaps not of the details of photochemical processes. [Pg.163]

The gravimetric determination of the residue from overall migration tests or extraction tests is at the milligram scale. As mentioned above, the EU limit for overall migration is 60 mg/kg. With some caveats, measuring at these levels is relatively simple in even the most basic laboratory and official methods are well described. [Pg.212]

Abstract Reliable, traceable and comparable measurements provide the rational basis for evaluation of the quality of a result and the starting point for recognized laboratory accreditation in any national area. Modern medical diagnostics and treatment involve rapidly rising numbers and types of clinical laboratory measurements, that are reliable. Therefore, the basic principles to be followed to assure the traceability of clinical measurements as required by the Romanian Laws of Metrology are reviewed. Main sources affecting the... [Pg.184]

Dyes are usually divided into water-soluble and water-insoluble groups. The water soluble group is further divided into anionic (acid) and cationic (basic) dyes. Gun 3 provides a comprehensive chart of the synthetic organic dyes. However, he does not address the resonant amphoteric dyes. The specific placement of the Rhodonines within his chart requires additional analysis and probably laboratory measurements to determine their relative level of amphoterism. The chart does not specifically delineate resonant dyes such as the Rhodonines. [Pg.52]

The latter form is the basic equation of diffusion generally identified as Fick s first law, formulated in 1855 [13]. Fick s first law, of course, can be deduced from the postulates of irreversible thermodynamics (Section 3.2), in which fluxes are linearly related to gradients. It is historically an experimental law, justified by countless laboratory measurements. The convergence of all these approaches to the same basic law gives us confidence in the correctness of that law. However, the approach used here gives us something more. [Pg.45]

Measurement and Instrumentation in Engineering Principles and Basic Laboratory Experiments, Francis S. Tse and Ivan E. Morse... [Pg.5]

The study of elementary reactions for a specific requirement such as hydrocarbon oxidation occupies an interesting position in the overall process. At a simplistic level, it could be argued that it lies at one extreme. Once the basic mechanism has been formulated as in Chapter 1, then the rate data are measured, evaluated and incorporated in a data base (Chapter 3), embedded in numerical models (Chapter 4) and finally used in the study of hydrocarbon oxidation from a range of viewpoints (Chapters 5-7). Such a mode of operation would fail to benefit from what is ideally an intensely cooperative and collaborative activity. Feedback is as central to research as it is to hydrocarbon oxidation Laboratory measurements must be informed by the sensitivity analysis performed on numerical models (Chapter 4), so that the key reactions to be studied in the laboratory can be identified, together with the appropriate conditions. A realistic assessment of the error associated with a particular rate parameter should be supplied to enable the overall uncertainty to be estimated in the simulation of a combustion process. Finally, the model must be validated against data for real systems. Such a validation, especially if combined with sensitivity analysis, provides a test of both the chemical mechanism and the rate parameters on which it is based. Therefore, it is important that laboratory determinations of rate parameters are performed collaboratively with both modelling and validation experiments. [Pg.130]

Both, SAXS and XRD, are indirect methods but offer the advantage of providing reliable statistical information on particle size. XRD is particularly attractive as it can be performed on a very basic laboratory-based powder diffractometer, and for this reason is the most commonly used method. The technique involves measuring the peak broadening of the diffraction lines which, for perfect crystals, would be sharp except for a very small inherent broadening due to the uncertainty principle (i.e., there is not an infinite number of diffracting planes). In practice, however, these are broadened due to the instrumental optics and crystallite size. The most common approach to determining the crystallite size is to use the Scherrer relationship [170-172] ... [Pg.97]

Individuals handling even small quantities of hazardous waste such as might result from the remediation of a smaU spill should be provided with basic training on what to do with the materials, how to identify and label them, suitable containers for various classes of waste materials, and, of course, basic safety measures needed to protect themselves and others. This level of training should be provided to every new employee in an area or to each new graduate student in an academic institution. The material in this section will apply to handling spills that do not involve a release of a hazardous material into the environment, and that can be handled by in-house personnel, meaning either laboratory employees or safety employees who have... [Pg.433]

The main parameters playing important roles for electrochemical measurements are potential and current. As described in the previous chapter (chapter The Fundamentals of Corrosion Science and Engineering Equilibrium Theory and Its Meaning ), the potential always suggests the corrosion possibility. One of the typical examples is the potential-pH diagram, as already described. Therefore, the measurement of potential is one of the basic corrosion measurements on the laboratory scale. [Pg.33]

A considerable number of impact tests have been devised to characterize the impact resistance of plastics (78). To provide basic level of understanding of the relationship between laboratory-measured uniaxial and biaxial impact strength and the performance of the final plastic part, fracture mechanical analysis of impact tests needs to be discussed in terms of the specific setup of various types of impact test equipment. [Pg.167]

Applied General Chemistry—study of the general concepts of chemistry with an emphasis on industrial applications. Students measure physical properties of matter, perform chemical calculations, describe atomic and molecular structures, distinguish periodic relationships of elements, name and write inorganic formulas, write equations for chemical reactions, demonstrate stoichiometric relationships, and demonstrate basic laboratory skills. [Pg.42]

Level 1 precautions provide for basic containment measures that depend on adhering to standard microbiological practices. This level does not prescribe special primary or secondary barriers, except for a sink for washing hands. Safety equipment and facilities must meet requirements for the appropriate education sessions taking place in teaching laboratories. [Pg.86]


See other pages where Basic Laboratory Measurements is mentioned: [Pg.1022]    [Pg.1022]    [Pg.127]    [Pg.263]    [Pg.6]    [Pg.20]    [Pg.425]    [Pg.277]    [Pg.70]    [Pg.102]    [Pg.520]    [Pg.45]    [Pg.31]    [Pg.1296]    [Pg.90]    [Pg.234]    [Pg.110]    [Pg.248]    [Pg.6]    [Pg.654]    [Pg.358]    [Pg.35]    [Pg.214]    [Pg.1687]    [Pg.5]    [Pg.13]    [Pg.330]    [Pg.426]    [Pg.64]    [Pg.78]    [Pg.171]    [Pg.369]    [Pg.525]   


SEARCH



Basicity measurement

Laboratory measurements

Laboratory measures

© 2024 chempedia.info