Base line correction

Figures 24 and 25 demonstrate the success of deconvolution beyond the Doppler limit. Trace (a) in both figures is the undeconvolved data and represents the result of signal averaging over a large number of scans to produce a signal-to-noise ratio of approximately 300 1. The spectra were base-line corrected using a 0% absorption corresponding to the apparent base line between lines and a 100% absorption level was assumed, which gave reasonable relative intensities for the range of J values observed. The... Figures 24 and 25 demonstrate the success of deconvolution beyond the Doppler limit. Trace (a) in both figures is the undeconvolved data and represents the result of signal averaging over a large number of scans to produce a signal-to-noise ratio of approximately 300 1. The spectra were base-line corrected using a 0% absorption corresponding to the apparent base line between lines and a 100% absorption level was assumed, which gave reasonable relative intensities for the range of J values observed. The...
Fig. 29.1. Base line corrected DP voltammograms of (—) 5pM 8-oxoGua and of 60 pgmL-1 ( ) ssDNA and (—) dsDNA in pH 4.5 0.1 M acetate buffer. Fig. 29.1. Base line corrected DP voltammograms of (—) 5pM 8-oxoGua and of 60 pgmL-1 ( ) ssDNA and (—) dsDNA in pH 4.5 0.1 M acetate buffer.
Plasma and urine samples were profiled using a suitable HPLC system under specific conditions (gradient, column). Readout was done off-line by fraction collection of the HPLC ran followed by liquid scintillation counting. Biotransformation profiles were prepared by plotting the base-line corrected radioactivity against time-after-injection. [Pg.503]

FIGURE 8.6. Base-line corrected cyclic voltammograms of the Fc-Fe(CN)6 system at the NBAV interface. The concentration conditions for (aMd) and sweep rate are as in Figure 8.4B. The solid circles show the regression data obtained by assuming the IT mechanism. Reprinted from Ref. [30], with permission from American Chemical Society. [Pg.178]

This problem can be partially resolved by using a digital computer in which integration is performed after the spectrum is stored in the memory. Some careful base-line correction can be made before trial integration. The Fabri-tek 1070 instrument computers are hard-wired programmed for such operation, and a thorough examination performed in our laboratory indicated that a normal integration uncertainty of less than 1% can be obtained with this computer. [Pg.47]

The alternative, and far more advantageous, form of data processing is to store each detector output value as it is received (usually on a hard disc) and then process the results after the analysis has been completed. This method give complete flexibility in data reduction, allows the chromatogram to be reconstructed in a number of alternative forms and different algorithms selected for base line correction or peak area measurement, etc. It also allows specific portions of the chromatogram to be amplified to show the presence of trace materials. [Pg.75]

Base-line correction Selectable with storage firm ware... [Pg.3468]

The Interliss algorithm developed in Nantes (ref. 2) iterates in the complex plane from the raw frequency spectrum obtained after Fourier transformation without any phasis nor base line correction. The reproducibility of the FID treatment is thus optimized and small differences in the line intensities of different samples can be clearly shown. [Pg.510]

Figure 33D illustrates the fit of the model expressed by Eq. 8 to the enhanced tunneling current vs. substrate potential characteristics (z enh vs. Es). Jenh was obtained from the experimental data plotted in Fig. 33C after base line correction. The particular experiment led to reorganization energies A = 0.42 eV of the radical cation. The values of and y 1 indicate a complete potential drop at the reactive viologen center with the variation of r] and Ebias" For further details we refer to [269]. [Pg.245]

Chromatography, infrared spectroscopy, mass spectrometry, nuclear magnetic resonance spectroscopy, ultraviolet-visible spectroscopy and others have also been benefited from the properties of wavelet processing for data compression, noise removal, base-line correction, zero crossing and regression (Leung et al. 1998). [Pg.155]

The base-line corrected and converted into the absorption type spectra (Fig. 2) which exhibit prominent dichroism of Si-H2 wagging (665 cm 1), scissors (915 cm"1)... [Pg.220]

Determination through measurements in the UV below 240 nm is generally possible only with a considerable error, as a result of the interference of co-extracted impurities and scattered light. The errors can be reduced by using blanks on extracted clean silica gel samples [70, 213, 451, 614] or by base line corrections if the absorption spectrum... [Pg.152]

The key to a wider acceptance of high temperature GC of triacylglycerols on WCOT columns is the precision that can be attained in quantification. It is virtually essential that electronic integration be applied for peak area measurements, ideally with some form of automatic base-line correction. The response of the detector should in theory be... [Pg.118]

With proper-base line correction it is also possible to follow the kinetics. While isothermal kinetics is rather easy to evaluate, as is illustrated in Sect. 2.1.3, nonisothermal kinetics is somewhat more involved. The basic equation for nonisothermal kinetics is given in Fig. 2.9. An application and discussion is given in connection with the treatment of thermogravimetry in Sect. 7.5. Calorimetry of nonisothermal kinetics can be handled analogously. [Pg.280]

Base Line Correction, After the data smoothing process is finished, a base line correction procedure is performed as follows. Two alternative situations are considered here, one is in the neighbourhood of the base line and the other is in the neighbourhood of a peak. [Pg.21]

Computational Limits of integration, base-line correction, noise correction, double integration, and formula for final number... [Pg.449]

There is no perfect base-line correction, and all corrections are approximates. The simplest base line is a flat line that is parallel to the abscissa axis. Linear base lines with negative or positive slopes have been applied, as well as more complex forms. Several methods are available for base-line correction [75]. As a simple approach, a wedge defined by two points can be subtracted from the absorbance spectrum. Also, the entire spectrum or selected frequency ranges of the spectrum can be fit to a linear least-squares line, repeating the fitting until some predetermined deviation is satisfied. It is important to be able to correct a base line by using a method that avoids as much as possible subjective interaction. [Pg.110]

A base-line correction algorithm that is based on the use of a successive least-squares routine and that includes objective criteria on the convergence of a base line that is either linear or quadratic has been used [75]. [Pg.111]

Figure 33 Heat dissipation rate Figure 33 Heat dissipation rate <Pq) and torque profile during batch culture of Saccharopolyspora erythraea. The heat flow rate measured with the calorimeter is affected by torque variation and a linear base-line correction due to reactor volume decrease (sampling). Numbers to indicate disturbances due to torque variation as described in the text. (Redrawn from Reference [81] with permission of the author and publisher).
In the second case monitoring is performed on the column outlet with the main objective of identifying when the individual fractions elute. Post column detection is a very importemt part of analytical chromatographs where sophisticated diode array detectors may be utilized, and base line correction and peak area calculations are used for concentration determination of individual fractions. In contrast, in process chromatography, post column detection tends to be used purely qualitatively and may even be absent. [Pg.18]


See other pages where Base line correction is mentioned: [Pg.227]    [Pg.287]    [Pg.145]    [Pg.150]    [Pg.215]    [Pg.222]    [Pg.253]    [Pg.228]    [Pg.228]    [Pg.85]    [Pg.178]    [Pg.185]    [Pg.359]    [Pg.178]    [Pg.185]    [Pg.312]    [Pg.376]    [Pg.78]    [Pg.92]    [Pg.261]    [Pg.106]    [Pg.83]    [Pg.94]    [Pg.111]    [Pg.359]    [Pg.741]    [Pg.110]   
See also in sourсe #XX -- [ Pg.253 ]