Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Barriers cable

Aryl Phosphates. Aryl phosphates were introduced into commercial use early in the twentieth century for flammable plastics such as cellulose nitrate and later for cellulose acetate. CeUulosics are a significant area of use but are exceeded now by plastici2ed vinyls (93—95). Principal appHcations are in wire and cable insulation, coimectors, automotive interiors, vinyl moisture barriers, plastic greenhouses (Japan), furniture upholstery, conveyer belts (especially in mining), and vinyl foams. [Pg.478]

The aryloxyphosphazene polymers, on the other hand, have been used primarily ia wire and cable coatings and jackets and as fire-resistant, low smoke, closed-ceU foams and sound-barrier sheets. [Pg.257]

Fig. 4. Submersible oil well pump cable. A, SoHd copper conductor B, EPR-based insulation C, chemical barrier D, lead sheath E, filler E, galvanised... Fig. 4. Submersible oil well pump cable. A, SoHd copper conductor B, EPR-based insulation C, chemical barrier D, lead sheath E, filler E, galvanised...
Chemical degradation can be avoided by using closed stmctures, which may have protective covets or which may be fully hermetic, as well as by using unreactive metals. Barrier coatings ate effective in some cases, and polyethylene—polybutene grease (8) is used in some splicing connectors for telecommunications cable. [Pg.32]

The market for PPVC film and sheet is only slightly less than for wire and cable insulation. Uses are as diverse as seepage barriers, factory doors, inflatables, baby pants, car trim, covering materials for book bindings and document cases and shower curtains. UPVC film has also been widely used for packaging of food, particularly for shrink-wrap purposes, but this market has been subject to some substitution by polypropylene. [Pg.357]

Low-voltage electric resistance heater cables fixed to the structural floor slab and then protected within a 50 mm thickness of cement and sand to give a suitable surface on which the floor vapour barrier can be laid. The heating is thermostatically controlled, and it is usual to include a distance reading or recording thermometer to give visual indication of the temperature of the floor at several locations below the insulation. [Pg.182]

Where water will create a serious fire or personnel hazard, a suitable nonwater automatic extinguishing system should be considered. Penetrations through fire-rated floor, ceiling, and wall assemblies by pipes, conduits, bus ducts, cables, wires, air ducts, pneumatic tubes and ducts, and similar building service equipment should be protected in accordance with NFPA 101 , Life Safety Code. All floor openings should be sealed or curbed to prevent liquid leakage to lower floors. Door assemblies in 1 -hour rated fire barriers should be y4-hour rated. Door assemblies in 2-hour rated fire barriers should be 1 V2-hour rated. [Pg.309]

Cross-linked wre and cable, foam tubing, weather protection, and moisture barriers (e.g., powercable, building conduit, portable apparatus building control, instrument, shipboard, automotive, marine appliances, insulation of heating tubes)... [Pg.311]

After the barrier frame was in place, pipes for the injection/extraction wells, piezometers, and the sampling network were suspended in the tank from cables. Sand was then added in lifts to fill the remaining aquifer portion of the tank. After the aquifer material was in place the SMZ was packed into the permeable barrier frame. The pipes were buried in place as the tank and frame were filled. [Pg.166]

In most cases, an intrinsically safe circuit is put into practice so that a safety barrier or an Ex i-isolator or an Ex i-input/output is connected to measuring devices or positioning elements (sensors, actuators) located in a hazardous area via a cable (see Fig. 6.217). Hence, explosion protection cannot be purchased ready for use for the most part, but it has to be put into practice by the planner and electrician. Only in cases where apparatus and cables are... [Pg.386]

Electrical insulation, wires and cables, flexible printed circuits, ultrapure components for semiconductor manufacture, condensers, batteries, barrier films for packaging of sensitive electronic parts, films for photovoltaic modules... [Pg.57]

The diagram should show the power flow from its source, often in a control room, through the various locations of any intermediary junction boxes, barriers, or switches, and out to the load and back the different locations through which each cable passes (e.g., control... [Pg.582]

Tension member — The part of a floating oil containment boom that carries the load placed on the barrier by wind, wave, and current forces. Tension members are commonly made of wire cable or chain due to their strength and stretch resistance. [Pg.234]


See other pages where Barriers cable is mentioned: [Pg.612]    [Pg.115]    [Pg.57]    [Pg.218]    [Pg.432]    [Pg.309]    [Pg.505]    [Pg.372]    [Pg.160]    [Pg.540]    [Pg.244]    [Pg.63]    [Pg.162]    [Pg.612]    [Pg.302]    [Pg.297]    [Pg.183]    [Pg.4]    [Pg.627]    [Pg.638]    [Pg.639]    [Pg.800]    [Pg.505]    [Pg.607]    [Pg.198]    [Pg.448]    [Pg.398]    [Pg.497]    [Pg.193]    [Pg.105]    [Pg.679]    [Pg.39]   
See also in sourсe #XX -- [ Pg.181 ]




SEARCH



Cables

© 2024 chempedia.info