Avidin-biotin detection system testing

Liposome conjugates may be used in various immunoassay procedures. The lipid vesicle can provide a multivalent surface to accommodate numerous antigen-antibody interactions and thus increase the sensitivity of an assay. At the same time, it can function as a vessel to carry encapsulated detection components needed for the assay system. This type of enzyme-linked immunosorbent assay (ELISA) is called a liposome immunosorbent assay or LISA. One method of using liposomes in an immunoassay is to modify the surface so that it can interact to form biotin-avidin or biotin-streptavidin complexes. The avidin-biotin interaction can be used to increase detectability or sensitivity in immunoassay tests (Chapter 23) (Savage et al., 1992). [Pg.883]

The result is high-quality arrays that can be used with a fluorescence detection system in a manner similar to the glass slide microarrays, although only single color detection is used. cDNA is synthesized from a test RNA sample by reverse transcription followed by second strand synthesis. This is then used as a template for an in vitro transcription reaction to produce biotin-labeled cRNA. As well as introducing the label for detection, this step permits amplification of the RNA and thus enables less starting material to be used. The cRNA is hybridized to the GeneChip and the biotin detected with an avidin-... [Pg.10]

Two-site immunometric or sandwich assays that made use of two or more antibodies directed at different parts of the PRL molecule were next to be developed. As with other two-site IRMA assays, the capture antibody is attached to a solid phase separation system and the second or signal antibody is labeled with a detection molecule (e.g., radio-isotope, enzyme,fluorophor, or chemiluminescence tag ). In some assays, the capture antibody is attached to the wall of test tubes, plastic beads, microtiter plates, ferromagnetic particles, or glass-fiber paper. Other assays have used the strep-avidin approach that couples biotin to the signal antibody with avidin linked to a solid phase. Most of the current immunometric assays for PRL have been adapted to fully automated immunoassay systems. Compared with the older traditional RIA methods, these automated immunometric assays for PRL generally achieve lower detection limits (0.2 to 1.0 ig/L) and improved precision (interlaboratory coefficients of variation of <8% at all concentrations), and have superior specificity (<0.05% crossreactivity with GH). [Pg.1980]


See other pages where Avidin-biotin detection system testing is mentioned: [Pg.229]    [Pg.592]    [Pg.565]    [Pg.572]    [Pg.4877]    [Pg.396]    [Pg.2066]    [Pg.193]   
See also in sourсe #XX -- [ Pg.93 , Pg.94 , Pg.95 , Pg.96 ]

See also in sourсe #XX -- [ Pg.93 , Pg.94 , Pg.95 , Pg.96 ]




SEARCH



Avidin

Avidin, detection

Avidin-biotin

Avidin-biotin Systems

Avidin-biotin detection system

Biotin detection

Detection systems

System testing

Test systems

© 2024 chempedia.info