Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atomic operation mode

According to the distance from probe to the sample, three operation modes can be classified for the AFM. The first and foremost mode of operation is referred to as contact mode or repulsive mode. The instrument lightly touches the sample with the tip at the end of the cantilever and the detected laser deflection measures the weak repulsion forces between the tip and the surface. Because the tip is in hard contact with the surface, the stiffness of the lever needs to be less than the effective spring constant holding atoms together, which is on the order of 1 — 10 nN/nm. Most contact mode levers have a spring constant of <1 N/m. The defection of the lever can be measured to within 0.02 nm, so for a typical lever force constant at 1 N/m, a force as low as 0.02 nN could be detected [50]. [Pg.20]

Amine basicity is related to the presence of a lone pair of electrons on the nitrogen atom. Usually the interaction of an amine with an acid is not dangerous. There can be an accident when the acid-base complex formed is unstable or the operating mode is not correct. [Pg.285]

The details of the development of the EBRD process have been described by Pietsch et al.[187] There are two alternative operation modes in addition to the above continuous non-contact mode. The first one may be referred to as continuous contact atomization. In this mode, liquid metal contacts the bottom surface of the container instead of melt dripping, and then flows continuously from the center to the rim of the container. The second one may be termed discontinuous non-contact atomization. In this mode, the container is first filled by dripping melt while it is rotating at a very low speed of about 3 x 10-3 radians/s. The rotating speed of the container is then enhanced to about 14 radians/s while the metal or alloy is remelted and atomized. More than one focused electron beam may be used to provide energy for melting metal. [Pg.103]

Apart from atomization in the isothermal operation mode, there is another characteristic derived from the STPF concept that is worth commenting on, namely, matrix modification. [Pg.268]

For instance, IGOR can be ordered to produce all five-membered cyclic molecules with the empirical formula C2H N 0 , where the atoms have their customary valence schemes. The valence isomers of cvclooctatetraene (ref. 11, 12), the 1.3-dipoles (ref. 12), and the 278 conceivable five-membered cyclic phosphorylating reagents (ref. 12) have been generated by IGOR in this operating mode (Fig. 7.6). [Pg.147]

Ueyama H, Sugawara Y, Morita S (1998) Stable operation mode for dynamic nonconctact atomic force microscopy. Appl Phys A 66 S295... [Pg.473]

Optical spectroscopy ranging from Raman through Atomic is under considerable pressure to replace the "tried and true" photomultiplier tube (PMT) with multichannel devices. Two classes of solid state devices, the Charge Coupled Device (CCD) and the Charge Injection Device (CID), hold great promise for meeting this need. Operating modes of these devices are reviewed. Characteristics pertinent to analytical spectroscopy are presented. [Pg.133]

Figure 4. A schematic of an atomic force microscope (AFM), showing the primary components including the piezoelectric translator, the sample, the cantilever-tip assembly, and the photodetector. In its simplest operating mode (contact mode), the feedback loop of the AFM maintains a constant force between the tip and sample. The force is monitored by measuring the deflection of the cantilever-tip assembly using a laser beam scattered into a quadrant photodetector. Figure 4. A schematic of an atomic force microscope (AFM), showing the primary components including the piezoelectric translator, the sample, the cantilever-tip assembly, and the photodetector. In its simplest operating mode (contact mode), the feedback loop of the AFM maintains a constant force between the tip and sample. The force is monitored by measuring the deflection of the cantilever-tip assembly using a laser beam scattered into a quadrant photodetector.
The simplest operation mode in EELS is focusing the incident electron beam at the place of interest and analyzing the spectral distribution of the transmitted beam. The probe size can be as small as 1 run and can even be reduced down to atomic sizes in dedicated STEM instnunents. [Pg.906]

Metalloid compounds are usually determined by flowing-stream techniques hyphenated with hydride generation (HG)-atomic absorption or atomic fluorescence spectrometry. The continuous operation mode inherent to flow injection is specially suited for the latter detection technique as the tetrahyd-roborate reagent is a potential source of hydrogen for supporting the flame. Analyte preconcentration is frequently needed to detect the typical levels of metalloid species found in water matrices. In this context, cold trap collection of generated hydrides, sorbent extraction microcolumn methods, sorption... [Pg.1294]

Reactor entry pressure, bar Ph2 /Pco Selectivity/C atom % Alkenes in diesel, % Operating mode ... [Pg.1009]

The technical basis for the RAPID includes general experience with sodium cooled fast reactors. Specifically, the RAPID concept includes no control rods but incorporates the passive lithium expansion modules, lithium injection modules and lithium release modules to enable an operator-free operation mode. These systems utilize Li as a liquid poison instead of B4C rods. To verify the reactivity worth of Li, the criticality test [XVII-5] using the fast critical assembly (FCA) of the Japan Atomic Research Institute (JAERI) has been conducted. Also, the manufacturing technology of the lithium modules was mastered, and the performance and neutron radiography tests of the lithium expansion and lithium injection module pilots were conducted. [Pg.469]

VIII-1] OVCHINNIKOV, F.YA., VOZNESENSKY, V.A., SEMYONOV, V.V. Operation modes of NPP with the VVER-1000. M., Energoatomizdat, 1992 (in Russian). [VIII-2] INTERNATIONAL ATOMIC ENERGY AGENCY, Status of advanced light water reactor designs, IAEA-TECDOC-1391 (May 2004), Vienna. [Pg.310]


See other pages where Atomic operation mode is mentioned: [Pg.59]    [Pg.248]    [Pg.288]    [Pg.624]    [Pg.167]    [Pg.5]    [Pg.70]    [Pg.138]    [Pg.373]    [Pg.79]    [Pg.77]    [Pg.79]    [Pg.120]    [Pg.596]    [Pg.88]    [Pg.90]    [Pg.138]    [Pg.1]    [Pg.392]    [Pg.425]    [Pg.149]    [Pg.362]    [Pg.503]    [Pg.123]    [Pg.292]    [Pg.3110]    [Pg.174]    [Pg.68]    [Pg.340]    [Pg.532]    [Pg.648]    [Pg.33]    [Pg.87]    [Pg.534]    [Pg.37]   
See also in sourсe #XX -- [ Pg.121 , Pg.122 ]




SEARCH



Atomic force microscopy operating modes

Atomic force microscopy operation, modes

Atomizer operation

Operating mode

Operation mode

Operation modes mode

© 2024 chempedia.info