The capillary rise on a Wilhelmy plate (Section II-6C) is a nice means to obtain contact angles by measurement of the height, h, of the meniscus on a partially immersed plate (see Fig. 11-14) [111, 112]. Neumann has automated this technique to replace manual measurement of h with digital image analysis to obtain an accuracy of 0.06° (and a repeatability to 95%, in practice, of 0.01°) [108]. The contact angle is obtained directly from the height through... [Pg.363]

Yaminsky and Yaminskaya [114] have used a Wilhelmy plate to directly measure the interfacial tension (and hence infer the contact angle) for a surfactant solution on... [Pg.363]

Now, in principle, the angle of contact between a liquid and a solid surface can have a value anywhere between 0° and 180°, the actual value depending on the particular system. In practice 6 is very difficult to determine with accuracy even for a macroscopic system such as a liquid droplet resting on a plate, and for a liquid present in a pore having dimensions in the mesopore range is virtually impossible of direct measurement. In applications of the Kelvin equation, therefore, it is almost invariably assumed, mainly on grounds of simplicity, that 0 = 0 (cos 6 = 1). In view of the arbitrary nature of this assumption it is not surprising that the subject has attracted attention from theoreticians. [Pg.123]

In principle, the two-angle interval method can produce all CBC parameters within a single measurement channel, uniquely providing ceU-by-ceU hemoglobin concentration. The mean of the concentrations provides an alternative (and direct) measurement of MCHC. The method also provides an alternative HGB measurement, because HGB may be set equal to (RBC x MCV x MCHC)/1000. This method, like the basic light-scattering method, uses the same flow cell to measure platelets and ted cells with the result that the method is capable of providing the CBC parameters RBC, HGB, HCT, MCV, MCHC, MCH, and PLT. The method can also count a sample s white blood cells if the sample s red blood cells have been lysed. [Pg.403]

Angle of repose Handling and storage Disposal Direct measurement... [Pg.540]

Reif, B., Hennig, M., Griesinger, C. Direct measurement of angles between bond vectors in high-resolution NMR. Science im, 276,1230-1233. [Pg.254]

Tjandra N, Bax A. Direct measurement of distances and angles in biomolecules by NMR in a dilute liquid crystalline medium. Science 1997 278 1111-1114. [Pg.94]

The impedance can be measured in two ways. Figure 5.23 shows an impedance bridge adapted for measuring the electrode impedance in a potentiostatic circuit. This device yields results that can be evaluated up to a frequency of 30 kHz. It is also useful for measuring the differential capacity of the electrode (Section 4.4). A phase-sensitive detector provides better results and yields (mostly automatically) the current amplitude and the phase angle directly without compensation. [Pg.314]

Spectra as in Fig. 3.17 can also be obtained as a function of polar and azimuthal angle, and with polarized UV light, enabling one to probe band structures in all directions [18]. In this chapter we limit ourselves to angle-integrated measurements of the electron density of states. [Pg.75]

Crystal structure correlations explore relationships between reactivity and actual structural parameters such as bond lengths and angles. Reactivity measured in terms of rate and equilibrium constants allows us to introduce the energy dimension directly, because these constants translate directly into... [Pg.125]

Since the discovery of the nuclear Overhauser effect (NOE, see previous section) [4, 5] and scalar coupling constants [36, 37] decades ago, NMR-derived structure calculations of biomolecules largely depended on the measurement of these two parameters [38]. Recently it became possible to use cross-correlated relaxation (CCR) to directly measure angles between bond vectors [39] (see also Chapt 7). In addition, residual dipolar couplings of weakly aligned molecules were discovered to measure the orientation of bond vectors relative to the alignment tensor (see Sect 16.5). Measurement of cross-correlated relaxation was described experimentally earlier for homonuclear cases [40, 41] and is widely used in solid-state NMR [42 14]. [Pg.362]


See other pages where Angle direct measurement is mentioned: [Pg.362]    [Pg.2838]    [Pg.181]    [Pg.238]    [Pg.1880]    [Pg.136]    [Pg.111]    [Pg.710]    [Pg.32]    [Pg.11]    [Pg.67]    [Pg.87]    [Pg.208]    [Pg.291]    [Pg.170]    [Pg.143]    [Pg.561]    [Pg.564]    [Pg.571]    [Pg.197]    [Pg.280]    [Pg.346]    [Pg.125]    [Pg.127]    [Pg.328]    [Pg.208]    [Pg.260]    [Pg.374]    [Pg.150]    [Pg.24]    [Pg.134]    [Pg.86]    [Pg.96]    [Pg.281]    [Pg.245]    [Pg.7]    [Pg.52]    [Pg.263]    [Pg.364]   
See also in sourсe #XX -- [ Pg.44 ]




SEARCH



Angle measurements

Angles directed

Direct measure

Direct measurement

Direct measurement of static contact angle by video camera or goniometer