Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Angle Control

1 Impact of Beam Steering Errors on Device Performance [Pg.232]


In TSCs the thyristors are used in anti-parallel to switch a capacitor bank ON or OFF but without any phase angle control. A TSC therefore does not by itself generate any harmonics, unlike a TCR. [Pg.804]

A control system may have several feedback control loops. For example, with a ship autopilot, the rudder-angle control loop is termed the minor loop, whereas the heading control loop is referred to as the major loop. When analysing multiple loop systems, the minor loops are considered first, until the system is reduced to a single overall closed-loop transfer function. [Pg.64]

Quin, L.D. and Littlefield, L.B., Importance of the structure of the phosphorus functionality in allowing dihedral angle control of vicinal 13C-31P coupling. Carbon-13 NMR spectra of 7-substituted bicyclo[2,2,l]heptane derivatives,. Org. Chem., 43, 3508, 1978. [Pg.142]

Half-shade angle control -Polarizer prismv Lippich half-shade prism... [Pg.1322]

Retainer ring -Backside pressure -Backside topography -Speed control -Angle control by Mg, Bg. [Pg.68]

Biichner funnel and treated as described in Part B. The i-antipode is immediately precipitated from the filtrate by slow addition, with stirring, of 100 ml. of ice-cold ethanol. The green precipitate is collected on a 5-cm. Buchner funnel, washed with three 10-ml. portions of ice-cold ethanol or methanol, and air-dried. The yield is approximately 0.50 g. (91%). For a 0.032% aqueous solution in a 1-dm. tube, = —0.62°, and [a] = —1940°. The high optical density of even so dilute a solution makes observation of the field difficult. With the Rudolph high-precision polarime-ter, the half-shade angle control should be used at its maximum opening. [Pg.209]

The high optical density of even dilute solutions makes observation of the field difficult. The half-shade angle control on the Rudolph high-precision polarimeter should be opened to the maximum extent. [Pg.142]

The choice of endstation design and the mechanism of beam scan can also compromise angle control. We consider several examples below. [Pg.234]

Neuhaus et al. first introduced FLIPSY (flip angle adjustable one-dimensional NOESY) in 1996 and re-evaluated the pulse sequence in 2008 for use with meta-bonomics projects. The modified FLIPSY is similar to the original (Figure 6C) with the exception of a small homospoil gradient prior to the flip-angle controlled pulse and just after the presaturation period. [Pg.57]

Supplier Material Solar specular transmittance (%) at 0.59° cone angle (control value)... [Pg.108]

Two other categories of ion implanter deserve mention. First, the hybrid ribbon beam system is unique since the broad, unscanned ion beam does not scan off the wafer in the x-direction. Overscan does occur in the slow mechanically scanned direction, however. While offering an advantage for beam utilization, the ribbon beam must sacrifice uniformity and angle control to some degree. Second, Varian s broad beam approach utilizing nonmass-analyzed plasma doping. [Pg.231]

The surface characteristics of metallic and other substrates frequently require modification to meet particular criteria often, it is important to alter the surface energy of a substrate for a particular application. Here, contact angles control a variety of important surface properties, such as wettability, detergency and waterproofing, etc. The contact angle is defined simply as the... [Pg.512]

BBUGVACT (black box under glass variable angle controlled temperature)... [Pg.716]

Veltink, P.H., Chizeck, H. J., Crago, P.E., and El-Bialy, A., Nonlinear joint angle control for artificially stimulated muscle, IEEE Trans. Biomed. Eng. BME-39 368-380,1992. [Pg.249]

Power to such a furnace is typically provided from the secondary output of a 24 V/100 A transformer, controlled by a variac or phase angle controller on the primary input. [Pg.223]

The manipulator (Figs. 1 and 8) consists of a set of cast iron, mild steel and titanium links assembled together as a single chain and wound onto a drum in the main containment. The links are driven on and off the drun and hence up and down the mast by a scroll drive which operates on rollers on each link. The serving shoe angle controls the azimuth of the extended links, whilst the whole manipulator rotates thus allowing the knuckle end to be positioned at any desired position. [Pg.283]

Surface tension Combined with the particle/liquid contact angle, controls the moisture content of dewatered filter cakes. [Pg.253]

Recording methods also differ with which clompleteness a region of reciprocal space can be measured. In the analysis of crystalline powders, where the orientations of the lattice planes are expected to show a statistical distribution, the largest measurable glancing angle controls the ex-... [Pg.384]

Baur, G, Wittwer, V Berreman, DW (1976). Determination of the tilt angles at surfaces of substrates in liquid crystal cells. Physics Letters A, Vol. 56, No. 2, (Mar), pp. 142-144. Chen, TJ Chu, KL (2008). Pretilt angle control for single-cell-gap transflective liquid crystal cells. Applied physics letters, Vol. 92, No. 9, (Mar), pp. 091102. [Pg.102]


See other pages where Angle Control is mentioned: [Pg.804]    [Pg.6]    [Pg.147]    [Pg.505]    [Pg.216]    [Pg.230]    [Pg.231]    [Pg.232]    [Pg.232]    [Pg.233]    [Pg.235]    [Pg.275]    [Pg.216]    [Pg.230]    [Pg.232]    [Pg.232]    [Pg.233]    [Pg.235]    [Pg.16]    [Pg.712]    [Pg.371]    [Pg.427]    [Pg.83]    [Pg.66]   


SEARCH



Angle control valve

Control steering-angle sensors

Microgroove surface control of pretilt angle direction

Polyimides pretilt angle control

Pretilt angle control

Pretilt angle controllable

© 2024 chempedia.info