Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scaling amplifier

The hot alignment eheek is used to determine the aetual thermal growth, and then the final shim ehanges are made if needed. This example addresses only vertical movements. Horizontal movements are obtained in a similar fashion. The graphic plot uses an amplified scale on the vertical Y axis of one inch equals five mils vertical growth, while the X axis has a scale of one inch equals 10 inches (25 cm) of train length. [Pg.629]

Combinatorial Hbraries are limited by the number of sequences that can be synthesized. For example, a Hbrary consisting of one molecule each of a 60-nucleotide sequence randomized at each position, would have a mass of >10 g, weU beyond the capacity for synthesis and manipulation. Thus, even if nucleotide addition is random at all the steps during synthesis of the oligonucleotide only a minority of the sequences can be present in the output from a laboratory-scale chemical DNA synthesis reaction. In analyzing these random but incomplete Hbraries, the protocol is efficient enough to allow selection of aptamers of lowest dissociation constants (K ) from the mixture after a small number of repetitive selection and amplification cycles. Once a smaller population of oligonucleotides is amplified, the aptamer sequences can be used as the basis for constmcting a less complex Hbrary for further selection. [Pg.236]

Figure 21. Noise spectrum of detector amplifiers. Note that both axes have logarithmic scale. There are two main components of noise - the white noise which is present at all frequencies, and the 1// noise that is dominant at low frequencies. 1// noise has a fractal structure and is seen in many physical systems. The bandpass of a measurement decreases for slower readout, and the readout noise will correspondingly decrease. A limit to reduction in readout noise is reached at the knee of the noise spectrum (where white noise equals l/f noise) - reading slower than the frequency knee will not decrease readout noise. Figure 21. Noise spectrum of detector amplifiers. Note that both axes have logarithmic scale. There are two main components of noise - the white noise which is present at all frequencies, and the 1// noise that is dominant at low frequencies. 1// noise has a fractal structure and is seen in many physical systems. The bandpass of a measurement decreases for slower readout, and the readout noise will correspondingly decrease. A limit to reduction in readout noise is reached at the knee of the noise spectrum (where white noise equals l/f noise) - reading slower than the frequency knee will not decrease readout noise.
After gas-phase oxidation reaction finished, the reactor wall surfece was coated with a thick rough scale layer. The thickness of scale layer along axial direction was varied. The scale layer at front reactor was much thicker than that at rear. The SEM pictures were shown in Fig. 1 were scale layers stripped from the reactor wall surface. Fig. 1(a) was a cross sectional profile of scale layer collected from major scaling zone. Seen from right side of scale layer, particles-packed was loose and this side was attached to the wall surface. Its positive face was shown in Fig. 1(b). Seen from left side of scale layer, compact particles-sintered was tight and this side was faced to the reacting gases. Its local amplified top face was shown in Fig. 1(c). The XRD patterns were shown in Fig. 2(a) were the two sides of scale layer. Almost entire particles on sintered layer were characterized to be rutile phase. While, the particle packed layer was anatase phase. [Pg.418]

Fe which have full width 2r at 0.2 mm s . Other isotopes are less demanding, e.g., Au, for which the lines are ten times wider. Most spectrometers are equipped with electromechanical Mossbauer velocity transducers of the loudspeaker type. This technique is suitable for velocity variations ranging from less than 1 mm s full scale up to several cm s and covers the whole reach of hyperfine splitting for most of the common isotopes. Kalvius, Kankeleit, Cranshaw, and others [1-5] have been pioneers in the field, who laid foundations for the development of high-precision drives with feedback amplifiers for proper linear velocity scales with high stability and low hum. Other techniques for Doppler modulation have been developed for isotopes with extremely narrow hyperfine lines, e.g., Zn. For such isotopes, piezoelectric transducers are mostly used [6, 7], more details of which are found in Sect. 7.2.1. [Pg.27]

In the direct-reading instruments the emf of the cell is led through an (operational) amplifier across a standard high resistor yielding a current that is measured by a milliammeter calibrated to be read in pH units or millovolts. So, while the null-point system provides a truly potentiometric (non-faradaic) measurement where the off-balance adjustment remains limited to an interrupted temporary current draw-off, the direct-reading system represents an amperometric measurement where a continuous steady-state current draw-off takes place as long as the meter is switched on. In fact, the latter is a deflection method as a pointer indicates the pH units or millivolts by its deflection on the meter scale. [Pg.88]

The log count rate amplifier then amplifies the signal, which varies directly as the logarithm of the pulse rate, in the detector. The logarithmic count rate is then displayed on a meter with a logarithmic scale in counts per second. [Pg.88]


See other pages where Scaling amplifier is mentioned: [Pg.533]    [Pg.21]    [Pg.242]    [Pg.534]    [Pg.837]    [Pg.75]    [Pg.533]    [Pg.21]    [Pg.242]    [Pg.534]    [Pg.837]    [Pg.75]    [Pg.98]    [Pg.155]    [Pg.140]    [Pg.502]    [Pg.96]    [Pg.101]    [Pg.103]    [Pg.258]    [Pg.937]    [Pg.295]    [Pg.241]    [Pg.242]    [Pg.381]    [Pg.11]    [Pg.153]    [Pg.153]    [Pg.150]    [Pg.384]    [Pg.393]    [Pg.21]    [Pg.164]    [Pg.234]    [Pg.35]    [Pg.196]    [Pg.28]    [Pg.50]    [Pg.92]    [Pg.433]    [Pg.16]    [Pg.265]    [Pg.57]    [Pg.198]    [Pg.328]    [Pg.205]    [Pg.168]    [Pg.100]    [Pg.127]   
See also in sourсe #XX -- [ Pg.69 ]




SEARCH



Amplifiers

© 2024 chempedia.info