Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Amplified signal

As stated above the SQUID amplifier demands a low inductance Eddy current probe in order to be able to amplify signals up to 1 MHz. Low inductance Eddy current probes can be obtained by reducing the number of turns and by loosing the magnetic coupling between the tums. So magnetic cores should be avoided as well as tight wounded tums. For this purpose planar coils are the best... [Pg.302]

The amplified signal is passed to a double-balanced mixer configured as a phase-sensitive detector where the two inputs are the NMR signal (cOq) and the frequency of the synthesizer (03. gf) with the output proportional to cos(coq - co gj.)t + 0) + cos((coq + + 9). The sum frequency is much larger than the total bandwidth of the... [Pg.1475]

The amplified signal can be recorded directly by analog means but, more likely, the signal is digitized and processed by a computer (data system). [Pg.409]

The amplified signal from the transmitter is sent to the controller, which can be a computer or a little black box. There is not much we can say about the controller function now, except that it is likely a PID controller, or a software application with a similar interface. [Pg.92]

Nonsteroidal SERMs can also amplify signal-induced Ca2+ surges by inhibiting Ca2+-calmodulin-dependent membrane (Ca2+ + Mg2+)-ATPase. For instance, in synaptic plasma membranes and red cell membrane ghosts, tamoxifen and other triphenylethylene compounds (but not estradiol) have been... [Pg.99]

Obtain the sensor amplifier module board from your instructor, and examine it closely as follows. Notice the outlined horizontal box in the top center of the board—it is labeled instrumentation amplifier. Notice the symbol of an amplifier in this box (refer to Figure 6.10). Also, notice the inputs to the amplifier (labeled P14 and P15). These are sockets for the wires that will bring the input signals to the amplifier. It is the difference between these two signals that is amplified. The output of the amplifier (the amplified signal) is connected to sockets P19 and P20. Wires inserted into these sockets allow us to observe the amplified signal with a voltmeter. [Pg.171]

Ordinarily electrical amplification is used to compensate for differences in isotope abundances in the gas being measured. Thus, for carbon dioxide all three Faraday collectors are used with relative signal amplification at m/z = 44, 45, and 46 of 1 91 500 (since the normal abundance ratios 12C/13C 91, and 160/180 500). The amplified signals from all three detectors are thus comparable in intensity. Because of this feature, however, IRMS should only be used on gases with isotope composition close to natural abundance. Enriched material should not be used without careful recalibration since there is no guarantee of a linear response of electric signal to ion current for widely different isotope ratios. [Pg.221]

To eliminate the need for recalibration during a measurement and to obtain additional information, the Royco instrument was supplemented with a Nuclear Data ND-60 Multichannel Analyser (MCA). The amplified signal of the Royco 225 (which is proportional to the cimount of light scattered from each particle) was connected to the input of the MCA which cem count and classify pulsed input signals into as many as 2048 channels and display the results on a cathode ray tube (CRT). This number of cells is of course much more than required to determine the PSD. The data were therefore grouped into eleven cells whose limits were consistent with those used earlier (5), emd the counts in these cells were then printed on a Texas Instruments 743 KSR Data Terminal interfaced with the MCA. [Pg.124]

Nallur et al. (39) demonstrated that RCA is a sensitive method for detecting nucleic acid signals of microarrays. They reported that for DNA targets there was at least an 8000-fold increase in detection sensitivity over standard hybridization under the same conditions. Although this indicates a great potential to amplify signal from very small amounts of hybridized material, it is necessary to alter the hybridization protocol to account for the corresponding hybridization kinetics. [Pg.9]

The amplified signal from each detector is fed to two single pen recorders or to a dual pen recorder where the simultaneous responses are recorded. Highly selective detectors are commonly used as one of the detectors in combination with a flame detector. [Pg.348]

B gives input AGC, in which the gain and maximum output level are simultaneously adjusted by the volume control but where the input-referred compression threshold is unaffected. A separate trimmer adjustment is normally provided for the compression threshold. Control point A for the volume control gives an example of output AGC, in which the volume control simultaneously adjusts the gain and compression threshold, and a separate trimmer is used to set the maximum output level. Another option is feedforward compression, in which the detector is driven directly by the microphone signal a delay in the amplified signal relative to the control signal can then be used to reduce the attack overshoot in the compression circuit [Verschuure and Dreschler, 1993],... [Pg.429]


See other pages where Amplified signal is mentioned: [Pg.389]    [Pg.1179]    [Pg.38]    [Pg.566]    [Pg.41]    [Pg.189]    [Pg.15]    [Pg.216]    [Pg.78]    [Pg.331]    [Pg.84]    [Pg.83]    [Pg.84]    [Pg.212]    [Pg.84]    [Pg.422]    [Pg.447]    [Pg.103]    [Pg.108]    [Pg.156]    [Pg.380]    [Pg.256]    [Pg.90]    [Pg.94]    [Pg.318]    [Pg.217]    [Pg.321]    [Pg.261]    [Pg.43]    [Pg.392]    [Pg.393]    [Pg.308]    [Pg.975]    [Pg.1157]    [Pg.35]    [Pg.141]    [Pg.48]    [Pg.274]    [Pg.241]    [Pg.194]   
See also in sourсe #XX -- [ Pg.810 ]




SEARCH



Amplifier, signal

Amplifiers

© 2024 chempedia.info