Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Acceptance plans

Are there appropriate planning, training, drills, and equipment for response to emergencies If yes, ask to review the emergency response plan and training records. Be aware that for some facilities, an acceptable plan is to evacuate and call the fire department. [Pg.32]

Once the etncrgency has been cotnmunicated, an appropriate response by the public must be evoked. For tliis to occur, an accepted plan tliat people know and understand tnust be put itito effect. Sitice an etncrgency cati quickly become a disaster if panic ensues, the plan should include the appropriate countermeasures. [Pg.92]

Given that there were numerous alternatives for the resources, including demand-side management, interruptible loads, and off-system purchases, many case studies were ncccssai y. Each plan for service to future loads had to be tested for conformance with system and regional reliability criteria. The plans were further examined for cost, including losses, and examined for flexibility. Any acceptable plans had to... [Pg.1200]

Rule 1 Keep an open mind. If preconceived ideas dominate, you may wind up with the wrong plan and get less from your retirement than is possible. For example, you don t abandon leisure activities if you accept Plan B or Plan C. [Pg.67]

Administrator s decision to accept plan of Mississippi Authority and order suspending hearing for the pesticide chemical mirex. [Pg.239]

A similar analysis using the attributes portion of the acceptance plan is just as disturbing. Table 15 summarizes the number of dosage units outside 85.0-115.0% and 75.0-125.0% for the 1000 batches produced under the four conditions. [Pg.579]

There are several other activities in this phase beyond measurement. One should ensure that the implementation conditions for the product or system are consistent with the assumed conditions upon which the design is based. This is tdso the point at which the later steps of stakeholder acceptance plans are executed, typically with a broader set of people than those who participated in the early steps of the plan. This phase also often involves technology-transition considerations in general. [Pg.1308]

Future success of a project is often dependent on the production of an acceptable plan, and this demands consensus amongst the whole team. Updated regularly with activity progress, this plan is also re-analysed to produce revised scheduling. There are two diagrammatic standards in network analysis ... [Pg.179]

Two different types of acceptance plans are frequently used Sampling by variables and Sampling by attributes. [Pg.414]

If the outcome variable is continuous, sampling by variables is the method of choice to construct an acceptance plan. [Pg.414]

An AQL of 1 % defects in the population has been chosen in this example. The producer s risk is then extremely high, namely about 25 % for a sample size n = 30 and will increase even more for larger sample sizes. Apparently it is not possible to obtain the desired acceptance plan by manipulating the sample size. The following example shows how to improve the characteristic and get a better result by changing the acceptance criterion as well. [Pg.417]

The design of an acceptance plan is therefore not only a statistical exercise, but requires a review of all potential options and interests. The options have a technical character what is feasible from a technical and economical point of view and will give a reliable outcome interests are in guaranteeing a safe and efficacious medicine and are in the interests of the producer. [Pg.418]

The Certification Plan for Reactor Analysis Computer Codes includes a user qualification section. This section contains a user qualification and function checklist that specifies the minimum requirements for each user level and the associated access (authorization or control) level (i.e., from apprentice to proprietor) necessary to perform required code alterations. DOE review of this Certification Plan for Reactor Analysis Computer Codes indicated that it is an acceptable plan for access control. At present, master copies for many of the codes listed in the Certification Plan are archived in the Software Configuration Management System (SCMS), which is controlled by the NRTSC Scientific Computations Section (SCS). [Pg.169]

Based on the above evaluation, the DOE staff concludes that WSRC has prepared an acceptable plan for the development and approval of power ascension test procedures. The exact scope of power ascension testing and the techniques to be used for the K-Reactor Restart and Power Ascension Test Program are not completely developed at this time. The staff will review the procedures developed for power ascension testing when they have been completed and made available for review. The closure of the open item specified above will be adequate to satisfy the restart criteria. [Pg.342]


See other pages where Acceptance plans is mentioned: [Pg.71]    [Pg.297]    [Pg.534]    [Pg.152]    [Pg.141]    [Pg.405]    [Pg.414]    [Pg.416]    [Pg.160]    [Pg.202]    [Pg.205]   
See also in sourсe #XX -- [ Pg.414 ]




SEARCH



© 2024 chempedia.info