Wires related systems

However, careful kinetic measurements on related systems showed the invalidity of wire-type behavior [41]. Furthermore, Sen and coworkers [42] recently showed that the appearance of rapid, long-distance charge transfer for metallointercalators may be an artifact caused by the formation of aggregates. Currently, there are no data that clearly support the existence of a coherent transfer process in DNA over a distance greater than one or two base pairs [43, 44]. [Pg.161]

Separate rooms should be provided for I/O wiring panels, the process distributed control computer hardware and related systems. Motor Control Centers (MCC), UPS, and battery rooms. A minimum 1-hour fire-rated partition wall should be provided to ensure isolation of I/O and MCC areas from control rooms. [Pg.304]

When developing new safety related systems, especially in automotive industry, there is the need to verify that the safety of the new system is not worse than the safety of the old system. So, even if the reliability is worse, what has to be expected when new functions are implemented with new components, the safety can be equal or even better. Furthermore, it is possible, to charge the worse reliability against improved safety due to additional functions. But how can systems with nearly the same functions but very different structures, like for example a conventional braking system and a brake-by-wire-sy stem, be compared against each other ... [Pg.1469]

The status of safety-related systems and fiinctions is presented in a similar way, in accordance with the organization of the Emergency Operation Procedures (EOP). The parameters that are of immediate interest in a disturbance situation, are presented in a direct form. This means that the reactor pressure vessel with in- and outflow connections, together with neutron flux, water level, and reactor pressure, as well as control rods fiilly in (or not), are displayed directly. Other safety functions are indicated as normal, disturbed or failed in a similar way as for the plant overview, with detailed information at the reactor operator s desk. In this context, it can be noted that the computer-based reactor scram function via the reactor protection system (RPS) has been supplemented by a scram backup system that is implemented in hard-wired equipment. [Pg.48]

Calculation of long-term interference voltages is involved with a multiconductor problem which, in contrast to the short-term interference that derives from a one-pole grounding short circuit, in this case is related to the superposition of alternating magnetic fields of all the conductors of one or several three-phase systems as well as the ground wire. [Pg.519]

Figure 4.15. Digital display and wire connections related to the 8 monitor channels which can be managed by the environmental data acquisition system of beamline BW4, HASYLAB, Hamburg... [Pg.78]

Assuming that the heat transfer is made by conduction through the thermocouple wires, the heat flow rate (

[Pg.137]

The distributed control system (DCS) hardware areas are often referred to as "process computer rooms." I/O Rooms contain the incoming and outgoing wiring, cables and data highway links, and often small transformers and other related electrical equipment. Often, additional space is needed for a master process engineering computer terminal/work station for process control system changes and for critical safety instrumented systems (SIS) for interlocks and emergency shutdowns. [Pg.305]

Fig. 7.10. Cutaway of a cold cathode (Penning) gauge. The wire anode (A) is connected through a ceramic insulator (i) to the high-voltage lead (H). Under the influence of the magnetic field created by M, the elcclrons travel a long spiral path between the body and the anode. The current, which arises from electrons and positive ions of the ionized gas molecules, is related to the pressure. The open end (C) is attached to the vacuum system. Fig. 7.10. Cutaway of a cold cathode (Penning) gauge. The wire anode (A) is connected through a ceramic insulator (i) to the high-voltage lead (H). Under the influence of the magnetic field created by M, the elcclrons travel a long spiral path between the body and the anode. The current, which arises from electrons and positive ions of the ionized gas molecules, is related to the pressure. The open end (C) is attached to the vacuum system.

See other pages where Wires related systems is mentioned: [Pg.256]    [Pg.305]    [Pg.449]    [Pg.98]    [Pg.1695]    [Pg.38]    [Pg.75]    [Pg.176]    [Pg.287]    [Pg.385]    [Pg.1918]    [Pg.59]    [Pg.1122]    [Pg.313]    [Pg.1059]    [Pg.153]    [Pg.84]    [Pg.595]    [Pg.40]    [Pg.126]    [Pg.256]    [Pg.43]    [Pg.680]    [Pg.76]    [Pg.134]    [Pg.61]    [Pg.126]    [Pg.62]    [Pg.23]    [Pg.382]    [Pg.187]    [Pg.208]    [Pg.55]    [Pg.237]    [Pg.224]    [Pg.200]    [Pg.141]    [Pg.736]    [Pg.109]    [Pg.311]    [Pg.116]    [Pg.157]   
See also in sourсe #XX -- [ Pg.256 ]