Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Wires labeling

Now place the copper wire labeled Ag in beaker 1 and the copper wire labeled K in beaker 2. Be careful not to submerge the label in the solution. [Pg.158]

Repeat steps 14 and 15 using the copper wire labeled Ag and rinsing the wire with the contents of beaker 1. Set both the copper wire and filter paper with residue aside to dry. [Pg.158]

An interesting correlation exists between the work function of a metal and its pzc in a particular solvent. Consider a metal M at the pzc in contact with a solution of an inert, nonadsorbing electrolyte containing a standard platinum/hydrogen reference electrode. We connect a platinum wire (label I) to the metal, and label the platinum reference electrode with II. This setup is very similar to that considered in Section 2.4, but this time the metal-solution interface is not in electronic equilibrium. The derivation is simplified if we assume that the two platinum wires have the same work function, so that their surface potentials are equal. The electrode potential is then ... [Pg.29]

As a measure of the temperature distribution over a typical sample when brought to a steady state by resistive heating there is plotted in Fig. 30 the resistance between equally spaced points on the wire (labeled 1 through 6) for different heating currents. Temperature differences... [Pg.302]

Label all wire ends as indicated on the wiring diagrams. Where no wiring label is indicated, a to/ffom designation shall be used. Jacketed power wiring which is color coded can have the labeling on the jacket. [Pg.328]

Each method has its benefits. Ascension numbering is easier to assign, and commonly available preprinted wire labels can be used. On the other hand, ascension numbers contain no hints as to wire piupose or path, and for that reason purpose codes are often added to the markings. [Pg.2385]

Wire needs to be clearly marked with a tab at both ends (where it goes and its number). Unfortunately no standard wire labeling system has been adopted however, there are sev-... [Pg.136]

Atoms are colored according to type (see table at right). Atoms may also be labelled by selecting Labels (labels may be turned off by selecting Labels a second time). Only wire and ball-and-wire models may be labelled. [Pg.7]

The mechanical friction between the electrode surfaee under investigation and a suitable probe depends on the electrode potential showing a maximum at Ep-. Of various experimental setups reviewed previously [69Boc2] the most recent one is used to measure the frietion between a test eleetrode in wire shape and a cylindrical slider sitting on the wire [69Boel]. Results are interpreted in terms of the repulsion of double layers being present on the wire and the slider [69Boe2]. (Data obtained with this method are labelled F). [Pg.185]

Observation of the electrode under examination being exposed to an electric field may yield information about the value of E. Any charge on the electrode, which can be a wire or a colloidal particle, will result in a movement in the external field. Assuming that the movement is due to charges being present on the electrode the rate of the movement should pass through a minimum at E i.c provided that specific adsorption is absent. (Data obtained with this method are labelled ED). [Pg.186]

Permanent deformation has also been investigated. The rate of flow of gold wires has been found to depend on the electrode potential with a minimum of the rate at E i.c [51Pfu]. The ereep of a lead eleetrode has been studied [69Lik]. (Data obtained with this method are labelled FL). [Pg.188]

A wooden or metal containment box surrounding the treated area is commonly used when a small quantity of test material is to be applied. The box, typically rectangular in shape and partially buried beneath the soil surface, serves to isolate the treated area from surrounding soil and protect against wind and water erosion. A one- to two-nozzle application boom that moves along guy wires or tracks is often used to ensure even application. Radiolabeled materials having two or more label positions often serve as replicates in these studies. [Pg.854]

Take a small piece of masking tape and use it to label each piece of wire. Write Ag on the wire to be used with the silver nitrate, and K on the wire to be used with the potassium nitrate. [Pg.158]

Coil each piece of copper wire so that it will fit in the funnel and can be submerged in the solutions present in each beaker with only the label remaining out of the solution. [Pg.158]

Weigh and record the mass of each piece of labeled copper wire. [Pg.158]

Place the filter paper labeled K in the funnel and carefully remove the K wire and place in the funnel. [Pg.158]

Once dry, weigh and record the masses of both the copper wire and filter paper (with possible residue) labeled K. [Pg.158]

Figure 10 Separation of ABEI-DSC-derivatized n-octylamine (2) and n-propylamine (3) with ECL detection. Remaining ABEI (1) and ABEI DSC (not shown) are also detected. Conditions 20% methanol in 5 mM sodium borate separation buffer, pH 10.9 5-s injection at 25 kV, 1.0 X 10 6 for each labeled amine 25-kV separation potential 10-mm platinum wire electrode. (From Ref. 85, with permission.)... Figure 10 Separation of ABEI-DSC-derivatized n-octylamine (2) and n-propylamine (3) with ECL detection. Remaining ABEI (1) and ABEI DSC (not shown) are also detected. Conditions 20% methanol in 5 mM sodium borate separation buffer, pH 10.9 5-s injection at 25 kV, 1.0 X 10 6 for each labeled amine 25-kV separation potential 10-mm platinum wire electrode. (From Ref. 85, with permission.)...
Low levels of resistance have been reported for some populations of Indian meal moth, almond moth, and red flour beetle populations in stored peanuts in the southeastern United States (Zettler et al., 1989), but no assessments are available for phosphine resistance in insect populations in mills, warehouses, processing plants, and other structural facilities. Phosphine can be corrosive to metals, particularly copper, electrical wiring, and electronic equipment (Bond et al., 1984), which limits its application in food processing facilities and warehouses. A new formulation of phosphine, in which phosphine gas is combined with carbon dioxide and released from a cylinder, alleviates some but not all of the corrosive effects of phosphine and is labeled for use as a structural treatment. [Pg.269]

Suppose you are given a collection of pieces of hardware a motor of some sort, a couple of push-button switches, and a meter. Suppose the motor has a few wires attached one labeled start, another stop, and a third tagged speed output . The buttons and meter also have labeled connections. Now imagine connecting the components as shown in Figure 10.7. [Pg.428]

Use a platinum wire loop or forceps to transfer the grid to the surface of a droplet of appropriately diluted primary antibody. Incubate from 30 min to overnight (depending on dilution, temperature, etc.). Longer incubations with higher dilutions of antibody produce more specific labeling. [Pg.105]

Obtain the sensor amplifier module board from your instructor, and examine it closely as follows. Notice the outlined horizontal box in the top center of the board—it is labeled instrumentation amplifier. Notice the symbol of an amplifier in this box (refer to Figure 6.10). Also, notice the inputs to the amplifier (labeled P14 and P15). These are sockets for the wires that will bring the input signals to the amplifier. It is the difference between these two signals that is amplified. The output of the amplifier (the amplified signal) is connected to sockets P19 and P20. Wires inserted into these sockets allow us to observe the amplified signal with a voltmeter. [Pg.171]

We have now labeled all of the pins. We will clean up the schematic a bit by moving the text labels. You can move any of the labels by dragging them. Move the text labels inside of the boxes so that we can easily wire the blocks together ... [Pg.82]

It is important to note that pin names do not specify net names or connectivity. In other words, commonly named pins are not automatically connected, and the net to which they are connected is not named the same as the pin names. Thus, as shown above, none of the blocks are connected. To connect the blocks, we need to wire them together. The schematic shown below shows the blocks wired together. Note that some wires are labeled with the text Vcc and Vee. This was done using net aliases as described in section l.H. Note also the wire fragments used for Vee. These wires are all given the same net name (Vee) and thus are connected. This is a shorthand method for connecting components without drawing wires all over your schematic ... [Pg.83]


See other pages where Wires labeling is mentioned: [Pg.154]    [Pg.518]    [Pg.526]    [Pg.626]    [Pg.316]    [Pg.185]    [Pg.267]    [Pg.273]    [Pg.274]    [Pg.181]    [Pg.1409]    [Pg.49]    [Pg.247]    [Pg.263]    [Pg.825]    [Pg.231]    [Pg.238]    [Pg.327]    [Pg.565]    [Pg.298]    [Pg.35]    [Pg.481]    [Pg.137]    [Pg.48]    [Pg.306]    [Pg.37]   
See also in sourсe #XX -- [ Pg.497 ]




SEARCH



© 2024 chempedia.info