Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Weight loss calculation

Actual weighed composition of sample, expressed as monohydrate (%) Anticipated TG weight loss of sample (%) Experimentally measured TG weight loss (%) Calculated monohydrate content, based on weight loss of 5.0% for the monohydrate (%)... [Pg.47]

TABLE 2—Comparison of conversion rates obtained from weight loss calculations and from thermal flow integration curves, for a pure Merck hemihydrate. [Pg.65]

When these precautions are taken into account, good correlations between the electrochemical weight loss, calculated by integrating Rp data from LPR measurements and gravimetric measurements [37] or measurement of corrosion pit volume [40] have been found. [Pg.289]

Analysis. The proximate analysis is based on determinations of volatile matter, moisture, and ash for a coal sample. Fixed carbon is then calculated by difference. Volatile matter is determined empirically by measuring the weight loss when coal is heated in a covered cmcible at either 950°C (ASTM D3175 or D5142) or 900°C (BS). [Pg.233]

Reliable pH data and activities of ions in strong electrolytes are not readily available. For this reason calculation of corrosion rate has been made using weight-loss data (of which a great deal is available in the literature) and concentration of the chemical in solution, expressed as a percentage on a weight of chemical/volume of solution basis. Because the concentration instead of the activity has been used, the equations are empirical nevertheless useful predictions of corrosion rate may be made using the equations. [Pg.409]

The critical current and primary passivation potential will not appear on an anodic polarisation curve when the steady-state potential already is higher than In such a case the potentiostat is unable to provide direct data for constructing the full polarisation curve. If that portion of the curve below the steady-state potential is desired, then the potential has to be held constant at several points in this range and corrosion currents calculated from corrosion rates as determined from solution analyses and/or weight losses. [Pg.1112]

The corrosion rate of a metal in terms of weight loss per unit area (g m" d ) or rate of penetration (mm y" ) can be calculated from Faraday s law if the current density is known. Conversely, the corrosion current density can be evaluated from the weight loss per unit area or from the rate of penetration. The following symbols and units have been adopted in deriving these relationships in which it is assumed that corrosion is uniform and the rate is linear ... [Pg.1355]

Both carbonates decompose to their oxides with the evolution of carbon dioxide. The decomposition temperature for calcium carbonate is in the temperature range 650-850 °C, whilst strontium carbonate decomposes between 950 and 1150°C. Hence the amount of calcium and strontium present in a mixture may be calculated from the weight losses due to the evolution of carbon dioxide at the lower and higher temperature ranges respectively. This method could be extended to the analysis of a three-component mixture, as barium carbonate is reported to decompose at an even higher temperature ( 1300 °C) than strontium carbonate. [Pg.433]

Those with type 1 diabetes mellitus produce insulin in insufficient amounts and tiierefore must have insulin supplementation to survive Type 1 diabetes usually has a rapid onset, occurs before die age of 20 years, produces more severe symptoms tiian type 2 diabetes, and is more difficult to control. Major symptoms of type 1 diabetes include hyperglycemia, polydipsia (increased thirst), polyphagia (increased appetite), polyuria (increased urination), and weight loss. Treatment of type 1 diabetes is particularly difficult to control because of the lack of insulin production by die pancreas. Treatment requires a strict regimen tiiat typically includes a carefully calculated diet, planned physical activity, home glucose testing several times a day, and multiple daily insulin injections. [Pg.487]

Heating the white reaction product to 140 C for one hour in vacuum caused a visible iodine evolution and approximately 40% weight loss. No further weight loss was observed up to 250°C. The gaseous products from the pyrolysis were not collected. The green product from pyrolysis analyzed Pu, 43 3% I, 50 2% C, 4.9 1%. The empirical formula PuI2C2H3 has the calculated composition Pu, 45.88% I, 48.75% C, 4.79%. [Pg.48]

Similarly, the number and types of tests completed will influence the cost in ways that can be very complex. Recently, the author was involved in designing a proof-of-principle study intended to assess the ability of a dietary supplement to enhance weight loss among subjects instructed to follow a reduced energy diet. Sample size calculations were run for two scenarios, the first using change in body weight as the primary outcome variable, the... [Pg.247]


See other pages where Weight loss calculation is mentioned: [Pg.261]    [Pg.266]    [Pg.353]    [Pg.376]    [Pg.930]    [Pg.358]    [Pg.138]    [Pg.434]    [Pg.144]    [Pg.261]    [Pg.266]    [Pg.8]    [Pg.972]    [Pg.106]    [Pg.950]    [Pg.461]    [Pg.261]    [Pg.266]    [Pg.353]    [Pg.376]    [Pg.930]    [Pg.358]    [Pg.138]    [Pg.434]    [Pg.144]    [Pg.261]    [Pg.266]    [Pg.8]    [Pg.972]    [Pg.106]    [Pg.950]    [Pg.461]    [Pg.16]    [Pg.445]    [Pg.456]    [Pg.557]    [Pg.1272]    [Pg.1134]    [Pg.49]    [Pg.328]    [Pg.551]    [Pg.207]    [Pg.80]    [Pg.194]    [Pg.530]    [Pg.594]    [Pg.1530]    [Pg.1531]    [Pg.1538]    [Pg.45]    [Pg.55]    [Pg.75]    [Pg.338]    [Pg.176]   
See also in sourсe #XX -- [ Pg.189 ]




SEARCH



Losses calculation

© 2024 chempedia.info