Voltage conversion

Voltage Conversions Between Different Reference Scales... [Pg.300]

Load Profile. The load profile used to simulate the proposed SHES reflects typical residential electricity needs in a remote (off-grid) application. In order to meet the requirements of the consumer load, the SHES must provide 58 kWh of AC electricity each day of the year, at 120 V and 60 Hz. The peak load each day is 10 kW, which occurs in the early evening, and the daily average load is 2.5 kW. The daily, peak, and average loads that the SHES system must supply also take into account losses encountered in AC/DC power inversion, DC/DC voltage conversion, and power requirements of various system components (i.e. controller). [Pg.178]

In addition to amplification, excitation, and filtering, signal-conditioning devices may provide isolation, voltage division, surge protection, and current-to-voltage conversion. [Pg.3687]

HL were set in the control circuit, that is, 1 clear water pump Ml, 2 clear water pump M2, indicating lamps HLl, HL2 and HL3 were also set in the aeration air blower M3. The above instruct lights were controlled auxiliary switch of contact device KM 1, KM2 and KM3. The overload protection of M1, M2, M3 and M4 were realized by four thermal relay FRl, FR2, FR3 and FR4. Overload protect was composed by closed-switch of contact KMl and intermediate relay KAl, KAl has also played the role of voltage conversion, the 220 V AC signal was converted into DC 24 V signals, which was sent into the PLC to complete overload control. [Pg.355]

Equation (8.13) holds under the assumption that the boost converter operates in continuous conduction mode and reduces for Rl =0 into the well known formula for the voltage conversion... [Pg.168]

The expression for the voltage conversion in (8.14) is to be replaced by a more complicated one in case the boost converter is operated in discontinuous conduction mode. [Pg.169]

In addition to control of potential, operational amplifiers can also be used for current measurement by means of current to voltage conversion. The high stability and noise immunity of operational amplifiers also allows for dramatic improvements in the analytical sensitivity, which can be varied over a wide dynamic range by simply changing the resistance of the feedback circuit. [Pg.241]

The advantages of this DEA-based approach are represented by compact design, the absence of mechanics, silent operation, wide temperature range, and low power consumption (about 10 mW). The actuation of this LSR requires 300 V. So, battery-operated devices must include voltage conversion electronics, e.g., a flyback converter, which takes up around 40 mm of PCB space wito Optotime s solution shown above. [Pg.749]

PVC product is a voltage conversion component specially developed for control and propulsion system. It supplies power for the control and propulsion systems, such as the central control unite, gyro, momentum wheel, SADA, earth sensor, sxm sensor, promoting power amplifier, etc. It is a certain type of key instrument directly related to the normal working of a certain satellite platform. Because of its high life and reliability requirement, the conventional test methods are not suitable for it. ALT of the PVC mainly including the following several aspects ... [Pg.1820]


See other pages where Voltage conversion is mentioned: [Pg.300]    [Pg.301]    [Pg.196]    [Pg.363]    [Pg.288]    [Pg.191]    [Pg.72]    [Pg.191]    [Pg.31]    [Pg.177]    [Pg.547]    [Pg.79]    [Pg.192]    [Pg.276]    [Pg.573]    [Pg.4]    [Pg.236]    [Pg.184]    [Pg.195]    [Pg.232]    [Pg.1127]    [Pg.346]    [Pg.987]    [Pg.988]    [Pg.378]    [Pg.379]    [Pg.212]    [Pg.2245]    [Pg.354]    [Pg.358]    [Pg.123]    [Pg.160]    [Pg.520]    [Pg.453]    [Pg.457]    [Pg.332]    [Pg.632]    [Pg.321]    [Pg.969]   