Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Venturi/spray tower system, adipic

Limestone Long-Term Tests with Two Scrubber Loops and Forced Oxidation. The venturi/spray tower system was modified for two-scrubber-loop operation with forced oxidation as shown in Figure 2. Two tanks were used in the oxidation loop (venturi loop) air was injected to the first of these tanks through a simple 3-inch diameter pipe below the agitator. Adipic acid was dry-fed to the spray tower effluent hold tank. This was accomplished by manually adding one-pound increments hourly to maintain specified concentration, usually totaling only a few pounds per hour. A small screw feeder would serve the purpose in a full-scale plant. [Pg.277]

Figure 2. Flow diagram for adipic acid-enhanced scrubbing in the venturi/spray tower system with two scrubber loops and forced oxidation. Figure 2. Flow diagram for adipic acid-enhanced scrubbing in the venturi/spray tower system with two scrubber loops and forced oxidation.
Adipic Acid-Enhanced Limestone Tests on the Two-Loop Venturi/Spray Tower System with Forced Oxidation... [Pg.279]

Table 7 gives the results of a typical bleed stream oxidation test, Run 915-1C, which was conducted with adipic acid-enhanced limestone on the venturi/spray tower system. The effluent slurries from the venturi and the spray tower were discharged into a common effluent hold tank. The scrubber bleed stream was pumped from the effluent hold tank to an oxidation tank into which air was injected through a 3-inch diameter pipe. The final system bleed was withdrawn from the oxidation tank and sent to the solids dewatering system. [Pg.291]

Lime tests with One Scrubber Loop and Without Forced Oxidation. Tests with adipic acid in lime scrubbing also were impressive in enhancing S02 removal, both on the venturi/spray tower and TCA systems. Table 4 shows some typical results of adipic acid-enhanced lime tests from the Shawnee TCA without forced oxidation. The flow diagram for these tests is shown in Figure 3. [Pg.285]


See other pages where Venturi/spray tower system, adipic is mentioned: [Pg.274]    [Pg.277]   