Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ultraviolet index

In LC, the most common means for monitoring the eluant is to pass it through a cell connected into an ultraviolet spectrometer. As substances elute from the column, their ultraviolet absorption is measured and recorded. Alternatively, the refractive index of the eluant is monitored since it varies from the value for a pure solvent when it contains organics from the column. [Pg.250]

Optical Properties. Teflon FEP fluorocarbon film transmits more ultraviolet, visible light, and infrared radiation than ordinary window glass. The refractive index of FEP film is 1.341—1.347 (74). [Pg.361]

Microscopy (qv) plays a key role in examining trace evidence owing to the small size of the evidence and a desire to use nondestmctive testing (qv) techniques whenever possible. Polarizing light microscopy (43,44) is a method of choice for crystalline materials. Microscopy and microchemical analysis techniques (45,46) work well on small samples, are relatively nondestmctive, and are fast. Evidence such as sod, minerals, synthetic fibers, explosive debris, foodstuff, cosmetics (qv), and the like, lend themselves to this technique as do comparison microscopy, refractive index, and density comparisons with known specimens. Other microscopic procedures involving infrared, visible, and ultraviolet spectroscopy (qv) also are used to examine many types of trace evidence. [Pg.487]

The PLM can be used in a reflection or a transmission mode. With either mode, light of various wavelengths from ultraviolet to infrared, polarized or unpolarized, is used to yield a wide variety of physical measurements. With just ordinary white light, a particle or any object detail down to about 0.5 p.m (500 nm) in diameter can be observed to detect shape, size, color, refractive index, melting point, and solubiUty in a group of solvents, all nondestmetively. Somewhat larger particles yield UV, visible, or IR absorption spectra. [Pg.333]

Additions to the PLM include monochromatic filters or a monochromator to obtain dispersion data (eg, the variation in refractive index with wavelength). By the middle of the twentieth century, ultraviolet and infrared radiation were used to increase the identification parameters. In 1995 the FTIR microscope gives a view of the sample and an infrared absorption pattern on selected 100-p.m areas (about 2—5-ng samples) (37). [Pg.334]

Hplc techniques are used to routinely separate and quantify less volatile compounds. The hplc columns used to affect this separation are selected based on the constituents of interest. They are typically reverse phase or anion exchange in nature. The constituents routinely assayed in this type of analysis are those high in molecular weight or low in volatility. Specific compounds of interest include wood sugars, vanillin, and tannin complexes. The most common types of hplc detectors employed in the analysis of distilled spirits are the refractive index detector and the ultraviolet detector. Additionally, the recent introduction of the photodiode array detector is making a significant impact in the analysis of distilled spirits. [Pg.89]

The dielectric constant is a measure of the ease with which charged species in a material can be displaced to form dipoles. There are four primary mechanisms of polarization in glasses (13) electronic, atomic, orientational, and interfacial polarization. Electronic polarization arises from the displacement of electron clouds and is important at optical (ultraviolet) frequencies. At optical frequencies, the dielectric constant of a glass is related to the refractive index k =. Atomic polarization occurs at infrared frequencies and involves the displacement of positive and negative ions. [Pg.333]

Select the detector. To acquire molecular weight distribution data, use a general detector such as a refractive index detector. To acquire structural or compositional information, employ a more selective detector such as an ultraviolet (UV) or infrared (IR) detector. Viscometric and light-scattering detectors facilitate more accurate molecular weight measurement when appropriate standards are not available. [Pg.78]

These combined HDF and GPC separations require the use of detectors such as static light scattering or viscometers to help sort out the convoluted elution profiles seen in those type of experiments. It should also be remembered in these situations that the typical refractive index or ultraviolet detector responses may not be representative of the actual mass fraction of insolubles eluting from the column because of the significant light scattering that can occur with those large particles in the detector cell. [Pg.553]

Samples of the 1,4-dihydrobenzoic acid, after both the first and the second distillations, are transparent in the ultraviolet region between 220 mu and 300 m/i, indicating the absence of benzoic acid or conjugated dihydrobenzoic acids. The refractive index cited in Reference 3 is in error. [Pg.23]

If a laser beam produces in the outer atmosphere a spectrum spanning from the ultraviolet to at least the red, then the return light will follow different optical paths depending on the wavelength (Fig. 19). The air refraction index is a function of air temperature T and pressure P ... [Pg.264]

Mhatre, R. and Krull, I. S., Determination of on-line differential refractive index and molecular weight via gradient HPLC interfaced with low-angle laser light-scattering, ultraviolet, and refractive index detection, Anal. Chem., 65, 283, 1993. [Pg.53]

Many different detectors are used in RPLC, including ultraviolet-visible spectrophotometers (UV-VIS), refractive index (RI) detectors, electrochemical (EC) detectors, evaporative light-scattering detectors, fluorimeters, and... [Pg.151]

Detection in 2DLC is the same as encountered in one-dimensional HPLC. A variety of detectors are presented in Table 5.2. The choice of detector is dependent on the molecule being detected, the problem being solved, and the separation mode used for the second dimension. If MS detection is utilized, then volatile buffers are typically used in the second-dimension separation. Ultraviolet detection is used for peptides, proteins, and any molecules that contain an appropriate chromophore. Evaporative light scattering detection has become popular for the analysis of polymers and surfactants that do not contain UV chromophores. Refractive index (RI) detection is generally used with size exclusion chromatography for the analysis of polymers. [Pg.109]

A.R. Siedle, 3M Central Research Laboratory If one of the extended structures described by Professor McCarley were truncated through a low Miller index plane, can one, following the appproach of Solomon, predict what metal orbitals would protrude from the surface so generated Have ultraviolet photoelectron spectra been obtained on single crystals of any of these materials ... [Pg.280]


See other pages where Ultraviolet index is mentioned: [Pg.186]    [Pg.186]    [Pg.261]    [Pg.281]    [Pg.128]    [Pg.419]    [Pg.220]    [Pg.220]    [Pg.126]    [Pg.116]    [Pg.71]    [Pg.617]    [Pg.142]    [Pg.661]    [Pg.147]    [Pg.126]    [Pg.153]    [Pg.12]    [Pg.195]    [Pg.814]    [Pg.127]    [Pg.14]    [Pg.705]    [Pg.114]    [Pg.100]    [Pg.110]    [Pg.29]    [Pg.40]    [Pg.36]    [Pg.78]    [Pg.383]    [Pg.394]    [Pg.115]    [Pg.7]    [Pg.8]   
See also in sourсe #XX -- [ Pg.448 ]




SEARCH



INDEX ultraviolet exposures

Ultraviolet irradiation 646 INDEX

Ultraviolet regions INDEX

Ultraviolet spectra INDEX

Visible-ultraviolet spectroscopy refractive index

© 2024 chempedia.info