Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ultraviolet , generally

In absorption spectroscopy a beam of electromagnetic radiation passes through a sample. Much of the radiation is transmitted without a loss in intensity. At selected frequencies, however, the radiation s intensity is attenuated. This process of attenuation is called absorption. Two general requirements must be met if an analyte is to absorb electromagnetic radiation. The first requirement is that there must be a mechanism by which the radiation s electric field or magnetic field interacts with the analyte. For ultraviolet and visible radiation, this interaction involves the electronic energy of valence electrons. A chemical bond s vibrational energy is altered by the absorbance of infrared radiation. A more detailed treatment of this interaction, and its importance in deter-... [Pg.380]

The so-called peak power delivered by a pulsed laser is often far greater than that for a continuous one. Whereas many substances absorb radiation in the ultraviolet and infrared regions of the electromagnetic spectrum, relatively few substances are colored. Therefore, a laser that emits only visible light will not be as generally useful as one that emits in the ultraviolet or infrared ends of the spectrum. Further, witli a visible-band laser, colored substances absorb more or less energy depending on the color. Thus two identical polymer samples, one dyed red and one blue, would desorb and ionize with very different efficiencies. [Pg.10]

Emission spectroscopy is confined largely to the visible and ultraviolet regions, where spectra may be produced in an arc or discharge or by laser excitation. Absorption spectroscopy is, generally speaking, a more frequently used technique in all regions of the spectrum and it is for this reason that we shall concentrate rather more on absorption. [Pg.42]

Both UPS and XPS of solids are useful techniques. So far as studies of adsorption by surfaces are concerned we would expect UPS, involving only valence orbitals, to be more sensitive. For example, if we wish to determine whether nitrogen molecules are adsorbed onto an iron surface with the axis of the molecule perpendicular or parallel to the surface it would seem that the valence orbitals would be most affected. This is generally the case but, because ultraviolet photoelectron spectra of solids are considerably broadened, it is the X-ray photoelectron spectra that are usually the most informative. [Pg.313]

Laser Photochemistry. Photochemical appHcations of lasers generally employ tunable lasers which can be tuned to a specific absorption resonance of an atom or molecule (see Photochemical technology). Examples include the tunable dye laser in the ultraviolet, visible, and near-infrared portions of the spectmm the titanium-doped sapphire, Tfsapphire, laser in the visible and near infrared optical parametric oscillators in the visible and infrared and Line-tunable carbon dioxide lasers, which can be tuned with a wavelength-selective element to any of a large number of closely spaced lines in the infrared near 10 ]lni. [Pg.18]

Degradation of polyolefins such as polyethylene, polypropylene, polybutylene, and polybutadiene promoted by metals and other oxidants occurs via an oxidation and a photo-oxidative mechanism, the two being difficult to separate in environmental degradation. The general mechanism common to all these reactions is that shown in equation 9. The reactant radical may be produced by any suitable mechanism from the interaction of air or oxygen with polyolefins (42) to form peroxides, which are subsequentiy decomposed by ultraviolet radiation. These reaction intermediates abstract more hydrogen atoms from the polymer backbone, which is ultimately converted into a polymer with ketone functionahties and degraded by the Norrish mechanisms (eq. [Pg.476]

Durability. Grass-like surfaces intended for heavy-duty athletic use should have a service life of at least eight years, a common warranty period provided by suppHers. Lifetime is more or less proportional to the ultraviolet (uv) exposure (sunlight) and to the amount of face ribbon available for wear, but pile density and height also have an effect. Color is a factor generally uv absorption is highest with red fabrics and least with blue. In addition, different materials respond differendy to abrasive wear. These effects caimot be measured except in simulated field use and controlled laboratory experiments, which do not necessarily redect field conditions. [Pg.534]


See other pages where Ultraviolet , generally is mentioned: [Pg.161]    [Pg.35]    [Pg.209]    [Pg.161]    [Pg.161]    [Pg.35]    [Pg.209]    [Pg.161]    [Pg.412]    [Pg.1179]    [Pg.1891]    [Pg.2070]    [Pg.2749]    [Pg.303]    [Pg.157]    [Pg.1143]    [Pg.1143]    [Pg.1144]    [Pg.410]    [Pg.20]    [Pg.378]    [Pg.379]    [Pg.122]    [Pg.134]    [Pg.67]    [Pg.291]    [Pg.305]    [Pg.361]    [Pg.474]    [Pg.61]    [Pg.238]    [Pg.446]    [Pg.25]    [Pg.26]    [Pg.48]    [Pg.219]    [Pg.525]    [Pg.262]    [Pg.290]    [Pg.22]    [Pg.328]    [Pg.460]    [Pg.410]    [Pg.456]   


SEARCH



© 2024 chempedia.info