Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tubing packed columns

In GLC the stationary phase is a liquid acting as a solvent for the substances (.solutes) to be separated. The liquid can be distributed in the form of a thin film on the surface of a solid support, which is then packed in a tube (packed column GC. PCGC) or on the wall of an open tube or capillary column (capillary GC, CGC). The term WCOT (wall-coated open tubular) is u.sed only for capillary columns coated with a thin film of a liquid. In GLC the separation is based on partition of the components between the two phases, the stationary phase and the mobile phase, hence the term partition chromatography. This mode of GC is the most popular and most powerful one. [Pg.201]

Column chromatography is a separation technique in which the stationary bed is within a tube. The particles of the solid stationary phase or the support coated with a liquid stationary phase may fill the whole inside volume of the tube (packed column) or be concentrated on or along the inside tube wall leaving an open, unrestricted path for the mobile phase in the middle part of the tube (open tubular column). Differences in rates of movement through the medium are calculated to different retention times of the sample. [Pg.40]

Inlets for syringe sampling are divided kito two main categories one for packed-column and the other for capiHary-column devices. Eor packed columns, all material kijected is carried by the mobile phase onto the column. The inlet is usually an open tube, but sometimes, albeit rarely, the inlet itself may be packed, eg, to assure that the first centimeters of the column do not become contaminated with degradation products or nonvolatile materials that may affect the efficacy of the column. [Pg.108]

Cyclohexene can be prepared on a large scale still more rapidly and efficiently by the distillation of cyclohexanol over silica geP or, better, activated alumina. Using a 25-mm. tube packed with 8- to 14-mesh activated alumina (Aluminum Company of America) and heated to 380-450 over a 30-cm. length, 1683 g. of cyclohexanol was dehydrated in about four hours. After separating the water, drying with sodium sulfate, and fractionating with a simple column, 1222 g. (89 per cent yield) of cyclohexene, b.p. 82-84 , was obtained. [Pg.27]

The column may be packed or it may be an open tube but in this example, a packed column will be specifically considered. The column is considered to have a length (L) and inlet and outlet pressures and inlet and outlet velocities of (Pi), (Po) (ui) and (uo), respectively. The pressure and velocity at a distance (x) from the front of the column is (Px) and (ux), respectively. According to D Arcy s equation for fluid flow through a packed bed, at any point in the column. [Pg.29]

The Golay equation [9] for open tubular columns has been discussed in the previous chapter. It differs from the other equations by the absence of a multi-path term that can only be present in packed columns. The Golay equation can also be used to examine the dispersion that takes place in connecting tubes, detector cells and other sources of extra-column dispersion. Extra-column dispersion will be considered in another chapter but the use of the Golay equation for this purpose will be briefly considered here. Reiterating the Golay equation from the previous chapter. [Pg.266]

Gel filtration separations are performed in an aqueous environment and the requirement on chemical resistance is therefore modest. Most column tubes and accessories (e.g., support net, sealings) withstand the solvent mixtures sometimes used in aqueous SEC such as 20% ethanol, 3 M guanidinium hydrochloride, 6 M urea, or 0.1 M HCl and 1 M NaOH, the last two being used for cleaning the packed column (see Section V). [Pg.61]

The instrumentation of HdC, including a pump, an injector, a column (set), a detector, and a recorder or computer, is very similar to size exclusion chromatography SEC). The essence of this technique is the column. There are two types of HdC columns open microcapillary tubes and a nonporous gel-packed column. This chapter emphasizes column technology and selection and the applications of this technique on the molecular weight analysis of macromolecules. [Pg.597]

HdC separation also occurs in the interstices of a packed column, although the configuration of channels is not as simple as a microcapillary tube. The... [Pg.601]

The product is analyzed by vapor phase chromatography using a 6-ft., f-in. O.D. copper tube, packed with 5% Bentone-34 (Wilkins Instrument Co.) and 0.5% XF-1150 (General Electric Silicone Products) on Diatoport-S (80-100 mesh) (F and M Co.) flow rate of helium 60 ml./min., oven temperature 85°. This column separates m-cymene (retention time 12 minutes) from />-cymene (retention time 10 minutes) but does not resolve the ortho isomer. The purity of the distilled w-cymene is above 98%. [Pg.43]

To measure k using the online detector, the packed columns were replaced by a length of l/l6 in OD ss tubing and peak areas corresponding to injections of various particle suspensions and sodium dichromate solutions were recorded on chart paper. The following analysis was then applied. [Pg.56]


See other pages where Tubing packed columns is mentioned: [Pg.55]    [Pg.667]    [Pg.55]    [Pg.667]    [Pg.157]    [Pg.945]    [Pg.106]    [Pg.107]    [Pg.1426]    [Pg.1439]    [Pg.17]    [Pg.378]    [Pg.257]    [Pg.261]    [Pg.352]    [Pg.357]    [Pg.58]    [Pg.3]    [Pg.29]    [Pg.926]    [Pg.431]    [Pg.41]    [Pg.206]    [Pg.10]    [Pg.102]    [Pg.387]    [Pg.157]    [Pg.945]    [Pg.30]    [Pg.37]    [Pg.71]    [Pg.110]    [Pg.112]    [Pg.181]    [Pg.262]    [Pg.321]    [Pg.326]    [Pg.377]    [Pg.835]    [Pg.181]   
See also in sourсe #XX -- [ Pg.55 ]




SEARCH



Column packing tube selection

Columns packings,supports,stationary phases,tubing

Packed columns

Packed columns, packing

Packed tube

© 2024 chempedia.info