Time-of-flight ICP

Figure 5.2 Overview of ICP-MS instrumentation quadrupole-based ICP-MS with and without colli-sion/reaction cell, sector field ICP-MS with single ion collector (ICP-SFMS) and multiple ion collector ICP-MS (MC-ICP-MS) and time-of-flight ICP-MS. Figure 5.2 Overview of ICP-MS instrumentation quadrupole-based ICP-MS with and without colli-sion/reaction cell, sector field ICP-MS with single ion collector (ICP-SFMS) and multiple ion collector ICP-MS (MC-ICP-MS) and time-of-flight ICP-MS.
The axial time-of-flight ICP-MS was introduced in 1998 by LECO (Renaissance, LECO, St. Joseph, MI) and has been commercially available for several years. A schematic of the ICP-ToF-mass spectrometer is shown in Figure 5.11. The analytical performance of this mass spectrometer, which allows 25 000 spectra to be measured per second and is thus faster than a quadrupole ICP-MS,... [Pg.134]

The purposes of this paper are to report on our efforts to evaluate the real world precision of laser ablation time of flight ICP-MS (LA-TOF-ICP-MS) replicate measurements on NIST standards and archaeological materials, and to... [Pg.299]

Figure 2. Comparison of TIMS and time of flight ICP-MS Pb isotope ratios from... Figure 2. Comparison of TIMS and time of flight ICP-MS Pb isotope ratios from...
Vanhaecke F., Moens L., Dams R., Allen L. and Georgitis G. (1999) Evaluation of the isotope ratio performance of an axial time-of-flight ICP mass spectrometer, Anal Chem 71 3297-3303. [Pg.339]

Burger, S., Riciputi, L.R. (2009) A rapid isotope ratio analysis protocol for nuclear sohd materials using nanosecond laser-ablation time-of-flight ICP-MS. Journal of Environmental Radioactivity, 100,970-976. [Pg.471]

Recently, ICP time-of-flight (ICP-TOF) mass spectrometers have been commercialized (Figure 45). The TOF analyser has a number of advantages over other analyzers used for ICP-MS. The fact that all masses in the spectrum can be monitored simultaneously is the main attraction for many ICP-MS users. Even for simple multielement analysis, scanning analyzers suffer from a decrease in sensitivity as the number of ions to be monitored is increased. The fact that over 30000 simultaneous mass spectra per second can... [Pg.705]

Sturgeon, R. E., Lam, J. W. H., and Saint, A. (2000) Analytical charactaistics of commercial orthogonal acceleration time-of-flight ICP mass spectrometry. J. Anal At. Spectrom., 15, 607. [Pg.81]


See other pages where Time-of-flight ICP is mentioned: [Pg.299]    [Pg.308]    [Pg.427]    [Pg.67]    [Pg.85]    [Pg.143]    [Pg.256]    [Pg.264]    [Pg.241]    [Pg.256]    [Pg.264]    [Pg.498]    [Pg.286]    [Pg.294]    [Pg.71]   
See also in sourсe #XX -- [ Pg.286 ]




SEARCH



Flight time

ICP time-of-flight mass spectrometry

Time-of-flight