Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Thermogravimetric analysis, desorption

For this purpose, all three catalyst supports were initially synthesized by a chemical vapor deposition (CVD) process and thereafter, using a wet impregnation method, loaded with cobalt as the active component for FTS. The as-synthesized Co/nanocatalysts were then characterized by applying electron microscopic analysis as well as temperature-programmed desorption, chemi- and physisorption measurements, thermogravimetric analysis, and inductively coupled plasma... [Pg.17]

Thermogravimetric analysis was performed on a Stanton Redcroft thermobalance in a flowing oxygen atmosphere at a heating rate of 10°C/minute. Thermal desorption/mass spectrometry (TD/MS) was carried out using am Extranuclear quadrupole mass spectrometer. 4 ... [Pg.210]

The catalysts were characterized by N2 adsorption-desorption isotherms, thermogravimetric analysis (TGA), temperature-programmed desorption of ammonia (NH3-TPD), X-ray diffraction (XRD), Raman spectroscopy, in-situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), and X-ray photoelectron spectroscopy (XPS). The procedures and experimental conditions have been detailed elsewhere [9]. [Pg.1004]

Thermogravimetric analysis (tga) and thermal desorption/mass spectrometry (td/ms) were used as described previously [5]. Sample sizes were typically 10 mg, with heating rates of 10°C/min. [Pg.590]

We have examined temperatured-programmed desorption (TPD) and thermogravimetric analysis (TGA) of isopropyiamine on a series of Si-, Co-, and Mg-substituted AIPO-5 samples. The TPD-TGA results on the substituted samples show ammonia and propene desorbing in a well-defined feature between 575 and 650K, a feature not observed on pure AIPO-5. The results suggest that TPD-TGA measurements of isopropyiamine may be useful in determining the framework concentrations and acid site densities for SAPO-5, CoAPO-5, and MAPO-5. [Pg.181]

A combination of GC/MS with thermogravimetric analysis simplifies analysis because the sample is ran directly from TGA which does not require sample preparation. TGA is interfaced with GC/MS through evolved gas collector which contains primary and secondary desorption elements which supply GC with samples. ... [Pg.514]


See other pages where Thermogravimetric analysis, desorption is mentioned: [Pg.167]    [Pg.233]    [Pg.211]    [Pg.108]    [Pg.255]    [Pg.1609]    [Pg.879]    [Pg.336]    [Pg.63]    [Pg.223]    [Pg.233]    [Pg.1]    [Pg.168]    [Pg.571]    [Pg.13]    [Pg.276]    [Pg.278]    [Pg.88]    [Pg.417]    [Pg.45]    [Pg.1708]    [Pg.483]    [Pg.650]    [Pg.288]    [Pg.189]    [Pg.459]    [Pg.181]    [Pg.151]    [Pg.207]    [Pg.571]    [Pg.71]    [Pg.27]    [Pg.32]    [Pg.495]    [Pg.25]    [Pg.686]    [Pg.93]    [Pg.303]    [Pg.457]   
See also in sourсe #XX -- [ Pg.108 ]




SEARCH



Thermogravimetric analysis

© 2024 chempedia.info