Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Temperature microbial control

Removal of dissolved materials. If operated at ambient temperatures, regenerate mixed bed at least once a week for microbial control. Use 4.5-10 pm absolute filters after mixing bed to stop resins and particulates from entering distribution system. [Pg.161]

Several important parameters control aquifer bioremediation projects. These include hydraulic conductivity, soil structure and stratification, groundwater mineral content, groundwater pH, temperature, microbial presence, and bench-scale testing, as further discussed below. [Pg.279]

Storage tank and in the circulation loop at ambient temperature most of the time (this requires an extra heat exchanger with cooling water on the shell side). To achieve microbial control, such system (or any system that includes ambient loop) needs to be periodically sanitized by heating up its contents to about 80° C and holding the temperature for at least 1 hr. The sanitization frequency can vary from once a day to once a week or less the lower the frequency is, the more attention to the studies proving the effectiveness of the microbial control shall be expected. [Pg.4046]

The diffusion process has not been designed to ensure sterility, although temperatures above 65°C significantly retard microbial activity. Sulfur dioxide, thiocarbamates, glutaraldehyde, sodium bisulfite, and chlorine dioxide are all used, occasionally disregarding their redox incompatibilities, to knock down or control infections. The most common addition point is to the water from the pulp presses as it is returned to the diffuser. Surfactants ate almost... [Pg.25]

Fermentation. The term fermentation arose from the misconception that black tea production is a microbial process (73). The conversion of green leaf to black tea was recognized as an oxidative process initiated by tea—enzyme catalysis circa 1901 (74). The process, which starts at the onset of maceration, is allowed to continue under ambient conditions. Leaf temperature is maintained at less than 25—30°C as lower (15—25°C) temperatures improve flavor (75). Temperature control and air diffusion are faciUtated by distributing macerated leaf in layers 5—8 cm deep on the factory floor, but more often on racked trays in a fermentation room maintained at a high rh and at the lowest feasible temperature. Depending on the nature of the leaf, the maceration techniques, the ambient temperature, and the style of tea desired, the fermentation time can vary from 45 min to 3 h. More highly controlled systems depend on the timed conveyance of macerated leaf on mesh belts for forced-air circulation. If the system is enclosed, humidity and temperature control are improved (76). [Pg.372]

Pesticides vary widely in their chemical and physical characteristics and it is their solubility, mobility and rate of degradation which govern their potential to contaminate Controlled Waters. This, however, is not easy to predict under differing environmental conditions. Many modern pesticides are known to break down quickly in sunlight or in soil, but are more likely to persist if they reach groundwater because of reduced microbial activity, absence of light, and lower temperatures in the sub-surface zone. [Pg.44]

There several DO probes available. Some well-known branded fermenters, like New Brunswick, Bioflo series and the B. Braun Biotstat B fermenters are equipped with a DO meter. This unit has a 2 litre fermentation vessel equipped with DO meter and pH probe, antifoam sensor and level controllers for harvesting culture. The concentration of DO in the media is a function of temperature. The higher operating temperature would decrease the level of DO. A micro-sparger is used to provide sufficient small air bubbles. The air bubbles are stabilized in the media and the liquid phase is saturated with air. The availability of oxygen is major parameter to be considered in effective microbial cell growth rate. [Pg.15]

The law also specifies the type of lighting, ventilation, and screening required to control the environment of the facility, together with other steps to assure that certain areas shall be protected from microbial contamination or dust or be maintained at special humidity and temperature conditions. These requirements are in order to ... [Pg.638]


See other pages where Temperature microbial control is mentioned: [Pg.86]    [Pg.1590]    [Pg.4043]    [Pg.4045]    [Pg.4047]    [Pg.443]    [Pg.294]    [Pg.3]    [Pg.139]    [Pg.97]    [Pg.97]    [Pg.127]    [Pg.79]    [Pg.33]    [Pg.354]    [Pg.284]    [Pg.44]    [Pg.171]    [Pg.271]    [Pg.133]    [Pg.2131]    [Pg.287]    [Pg.370]    [Pg.221]    [Pg.117]    [Pg.30]    [Pg.537]    [Pg.576]    [Pg.217]    [Pg.79]    [Pg.79]    [Pg.174]    [Pg.191]    [Pg.200]    [Pg.295]    [Pg.211]    [Pg.215]    [Pg.322]    [Pg.223]    [Pg.2]   