Tandem quadrupole mass spectrometer

Several other interface designs were introduced over this period, including continuous flow fast atom bombardment (CFFAB)" and the particle beam interface (PBI)," but it was not until the introduction of the API source that LC/MS applications really came to the forefront for quantitative analysis. Early work by Muck and Henion proved the utility of an atmospheric pressure interface using a tandem quadrupole mass spectrometer. [Pg.830]

Yost, R.A. Enke, C.G. Selected Ion Fragmentation With a Tandem Quadrupole Mass Spectrometer. J. Am. Chem. Soc. 1978,100, 2274-2275. [Pg.187]

Figure 4. Effects of ion kinetic energy on the MS/MS of 5-indanol (a) MS/MS obtained on MIKES instrument with 7000 eV translational energy (b) spectrum obtained on hybrid BQ (magnet followed by quadrupole) mass spectrometer 95 eV (c) spectrum obtained with QQ (tandem quadrupole) mass spectrometer at 35 eV... Figure 4. Effects of ion kinetic energy on the MS/MS of 5-indanol (a) MS/MS obtained on MIKES instrument with 7000 eV translational energy (b) spectrum obtained on hybrid BQ (magnet followed by quadrupole) mass spectrometer 95 eV (c) spectrum obtained with QQ (tandem quadrupole) mass spectrometer at 35 eV...
The method employs a tandem quadrupole mass spectrometer (MS/MS) as the final detector. The specificity of detection inherent in such a system significantly reduces the need for sample cleanup. This, in turn, improves productivity and cost-effectiveness relative to other high resolution and low resolution GC/MS analysis techniques. The aparatus and methods described are designed for use in a mobile laboratory, which permits on-site analyses. [Pg.262]

High-resolution spectroscopy of cluster ions has largely been limited to binary complexes between a molecular ion and a rare-gas atom or a hydrogen molecule. Much of this work had been done by the group of Maier and Dopfer in Switzerland. The spectrum of Ar-H20" given below in Fig. 17 is an excellent recent example of the rotationally resolved spectra that are possible using a tandem quadrupole mass spectrometer. Except for, Rg2-CH3 where Rg = Ar and larger clusters have yielded... [Pg.104]

Yost RA, Enke CG. Selected ion fragmentation with a tandem quadrupole mass spectrometer. J Am Chem Soc 1978 100(7) 2274—2275. [Pg.290]

Fig. 4.3 Schematic diagram and photo of tandem quadrupole mass spectrometer. The photo is taken from a Waters tandem-quadrupole instrument, featuring a travelling wave stacked ring RF-only collision cell. ( 2013, hyphen MassSpec)... Fig. 4.3 Schematic diagram and photo of tandem quadrupole mass spectrometer. The photo is taken from a Waters tandem-quadrupole instrument, featuring a travelling wave stacked ring RF-only collision cell. ( 2013, hyphen MassSpec)...
Fig. 6.7. The Lausanne photofragment-spectrometer for measuring spectra of cold biomolecular ions as well as their clusters with solvent molecules. In the center of the tandem quadrupole mass spectrometer is a 22-pole ion trap which can be cooled to temperatures below 10 K. The ions of interest are produced by an electrospray source, mass-selected in a quadrupole, and then injected into the trap where they are cooled via collisions with cold helium. After irradiating the ions with IR and/or UV laser pulses, the contents of the trap are ejected and sent through an analyzing quadrupole before being detected. Spectra are generated by monitoring the appearance of a particular fragment ion mass as a function of the laser wave length. Fig. 6.7. The Lausanne photofragment-spectrometer for measuring spectra of cold biomolecular ions as well as their clusters with solvent molecules. In the center of the tandem quadrupole mass spectrometer is a 22-pole ion trap which can be cooled to temperatures below 10 K. The ions of interest are produced by an electrospray source, mass-selected in a quadrupole, and then injected into the trap where they are cooled via collisions with cold helium. After irradiating the ions with IR and/or UV laser pulses, the contents of the trap are ejected and sent through an analyzing quadrupole before being detected. Spectra are generated by monitoring the appearance of a particular fragment ion mass as a function of the laser wave length.

See other pages where Tandem quadrupole mass spectrometer is mentioned: [Pg.381]    [Pg.793]    [Pg.157]    [Pg.185]    [Pg.204]    [Pg.204]    [Pg.340]    [Pg.3806]    [Pg.297]    [Pg.148]    [Pg.296]    [Pg.194]    [Pg.317]    [Pg.621]   
See also in sourсe #XX -- [ Pg.39 , Pg.71 , Pg.73 , Pg.85 , Pg.122 , Pg.165 , Pg.178 , Pg.188 , Pg.204 ]




SEARCH



Mass quadrupole

Mass spectrometer quadrupole

Quadrupol mass spectrometers

Quadrupole spectrometers

Tandem quadrupole

Tandem quadrupole mass

Tandem triple quadrupole mass spectrometer