Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Stationary-phase preparation, enantiomeric

Enantiomeric Stationary Phases. Chiral nonracemic chromatographic stationary phases prepared from p-cyclodextrin, derivatized with (R)- and (S)-NEI, and covalently bonded to a silica support are useful for the direct separation of enantiomers of a wide variety of compounds in both normal-phase and reversed-phase HPLC. ... [Pg.453]

Enantiomeric separations have become increasingly important, especially in the pharmaceutical and agricultural industries as optical isomers often possess different biological properties. The analysis and preparation of a pure enantiomer usually involves its resolution from the antipode. Among all the chiral separation techniques, HPLC has proven to be the most convenient, reproducible and widely applicable method. Most of the HPLC methods employ a chiral selector as the chiral stationary phase (CSP). [Pg.24]

In the next step, the best candidate from the series 2-oxo-4-(9-phenanthryl)-dihy-dropyrimidine 22 was prepared and isolated in enantiomerically pure form, then attached to a macroporous polymer support. To attach the isolated selector to the amino functionalized macroporous polymethacrylate support, a suitable reactive handle had to be introduced into the dihydropyrimidine. We chose to functionalize the methyl group at the C6 carbon atom by a simple bromination to afford (-)-22. Coupling of this compound to the amino functionalized support then gave the desired chiral stationary phase CSP 12 (Scheme 3-6) containing 0.20 mmol g of the selector. [Pg.82]

Because plasma and urine are both aqueous matrixes, reverse-phase or polar organic mode enantiomeric separations are usually preferred as these approaches usually requires less elaborate sample preparation. Protein-, cyclodextrin-, and macrocyclic glycopeptide-based chiral stationary phases are the most commonly employed CSPs in the reverse phase mode. Also reverse phase and polar organic mode are more compatible mobile phases for mass spectrometers using electrospray ionization. Normal phase enantiomeric separations require more sample preparation (usually with at least one evaporation-to-dryness step). Therefore, normal phase CSPs are only used when a satisfactory enantiomeric separation cannot be obtained in reverse phase or polar organic mode. [Pg.328]

Capillary gas chromatography (GC) using modified cyclodextrins as chiral stationary phases is the preferred method for the separation of volatile enantiomers. Fused-silica capillary columns coated with several alkyl or aryl a-cyclo-dextrin, -cyclodextrin and y-cyclodextrin derivatives are suitable to separate most of the volatile chiral compounds. Multidimensional GC (MDGC)-mass spectrometry (MS) allows the separation of essential oil components on an achiral normal phase column and through heart-cutting techniques, the separated components are led to a chiral column for enantiomeric separation. The mass detector ensures the correct identification of the separated components [73]. Preparative chiral GC is suitable for the isolation of enantiomers [5, 73]. [Pg.73]

Another way to obtain pure enantiomers is the separation of racemates through preparative chromatography on chiral stationary phases. In fact, the most significant developments over the last 20 years have been the application of GLC and HPLC techniques to the effective resolution of enantiomeric mixtures and to determining the enantiomeric ratio [7,8],... [Pg.4]

Key Words Preparative-scale GC, enantiomeric separation, chiral stationary phases, SMB-GC, nitrogen invertomer, inhalation anesthetics, terpenoids, flavours,... [Pg.267]

Advances in preparative enantioseparation by simulated moving bed (SMB) chromatography have occurred in the last 10 years. SMB was invented in the 1960s and was used by the petrochemical and sugar industries. Now with the improvements in stationary phases and hardware it is an option for the large-scale preparation of enantiomerically pure material. The majority of the latest published data are using either amylose- or cellulose-based phases because of their selectivity. There are now examples in the literature of the commercial separation on the multi-ton scale.8... [Pg.561]

The technique of boxcar injections (not to be confused with boxcar chromatography) can be extremely productive for iso-cratic elution in any mode of chromatography and should always be considered when scaling up a separation. The preparative HPLC of an enantiomeric mixture utilising a chiral stationary phase is described here to demonstrate the approach for separation of a binary mixture. [Pg.96]

Chiral Stationary Phases for GC and HPLC. Enantiomerically pure NEA has been used to prepare a variety of chiral stationary phases for liquid, gas, and supercritical fluid chromatography. These stationary phases are used to separate enantiomers without derivatization of the substrate with a chiral agent. [Pg.451]


See other pages where Stationary-phase preparation, enantiomeric is mentioned: [Pg.123]    [Pg.226]    [Pg.123]    [Pg.199]    [Pg.64]    [Pg.68]    [Pg.337]    [Pg.4]    [Pg.58]    [Pg.287]    [Pg.58]    [Pg.287]    [Pg.966]    [Pg.19]    [Pg.319]    [Pg.121]    [Pg.339]    [Pg.214]    [Pg.410]    [Pg.96]    [Pg.362]    [Pg.64]    [Pg.68]    [Pg.95]    [Pg.7]    [Pg.301]    [Pg.58]    [Pg.531]    [Pg.164]    [Pg.281]    [Pg.939]    [Pg.951]    [Pg.952]    [Pg.1007]    [Pg.711]    [Pg.721]    [Pg.64]   


SEARCH



Enantiomeric selection stationary phase preparation

Preparation phase

Stationary phases, preparation

© 2024 chempedia.info