Nylon 6 Nylon 66 3 1 Food Release Spray room temperature ... [Pg.991]

Paradichlorohenzenes Irritates eyes, nose, central nervous system. Also found in mildew control sprays, room deodorizers. [Pg.49]

MPC = Measuring point chimney concentration in mg/Nm MF = mass flow in g/h 2 Example Emissions measured in a spray-room... [Pg.1217]

Figure 18.1.6. Maximum concentration of n-butyl acetate in the spray-room of a joiner s with windows and door closed. A - Spray wall, B - Rack track for shelving the varnished parts. Figure 18.1.6. Maximum concentration of n-butyl acetate in the spray-room of a joiner s with windows and door closed. A - Spray wall, B - Rack track for shelving the varnished parts.
Does the facility have spray booths, spray rooms, or open surface tanks used for cleaning ... [Pg.414]

Zirconium Oxide (Zr02) (plasma sprayed) room temp. 6.96x10 ... [Pg.1283]

Location and application. Spray booths or spray rooms are to be used to enclose or confine all operations. Spray-finishing operations shall be located as provided in sections 201 through 206 of the Standard for Spray Finishing Using Flammable and Combustible Materials, NFPA No. 33-1969. [Pg.106]

Are spray painting op ntions performed in spray rooms or booths equipped with an appropriate exhaust system ... [Pg.185]

Spray Room A room in which spray-finishing operations not conducted in a spray booth are performed separately from other areas. [Pg.90]

Spray booths or spray rooms shall be used to confine all spray-finishing operations. [Pg.92]

Spray rooms, including floors, shall be constructed of non-combustible materials. [Pg.93]

Spray rooms shall have non-combustible lire doors and shutters. [Pg.93]

Example Emissions measured in a spray-room The usual technique of measuring VOC emissions in plants by means of the FID according to VDI 3481/page 3 has the shortcomings that individual components in the gas mixture cannot be measured separately, but only determined as total carbon. Also the device needs to be placed in the immediate vicinity of the measuring point and requires frequent calibration. [Pg.431]

Figure 17.1.6 shows the results of emission investigations in the spray-room of a joiner s with and without ventilation. Windows and doors were closed. The vamisher was standing in fi-ont of a spray-wall, opposite to him was placed a platform rack truck for shelving the varnished parts. Those areas in the joiner s, which showed roughly the same emission values of n-butyl acetate, are marked on each drawing. [Pg.432]