Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Size methods spinning

Clusters of the prototype magnetic metal, i.e. iron, have been investigated most extensively by density functional methods. In addition to the several studies of the iron dimer [197], the first extensive DFT optimization of geometry and spin state for Fe (a2 up to 4) has been reported in [198]. Further studies of the size-geometry-spin relation in iron clusters with n up to 7 have been reported in Refs [196, 199-201] (see Appendix C). [Pg.117]

There are a number of other technical details associated with HF and other ah initio methods that are discussed in other chapters. Basis sets and basis set superposition error are discussed in more detail in Chapters 10 and 28. For open-shell systems, additional issues exist spin polarization, symmetry breaking, and spin contamination. These are discussed in Chapter 27. Size-consistency and size-extensivity are discussed in Chapter 26. [Pg.21]

When a sample of ca 100 g has been obtained, a representative sample for use in size characterization equipment must then be taken. Some of the more modem methods of size characterization require as Htde as 1 mg of powder, thus obtaining a representative sample can be quite difficult. If the powder flows weU and does not contain too many fines, a device known as the spinning riffler (Fig. 4c) can be used. A spinning riffler consists of a series of cups that rotate under the powder supply. The time of one rotation divided into the time of total powder flow should be as large a number as possible. Although this device has been shown to be very efficient, problems can be encountered on very small (1 mg) samples, and the powder must be processed several times. Moreover, in order to avoid cross-contamination, cleanup after each of the sampling processes can be quite difficult. Furthermore, if the powder is cohesive and does not flow weU, the equipment is not easy to use. A siUca flow agent can be added to the powder to enable the powder to flow... [Pg.129]

In the atomizing process, a stream of molten zinc is broken into tiny droplets by the force of a pressurized fluid impinging on the stream. The fluid can be any convenient material, although air is normally used. The atomized drops cool and soHdify rapidly in a coUection chamber. The powder is screened to specified sizes. Particulate zinc is also produced by other methods such as electrolytic deposition and spinning-cup techniques, but these are not of commercial importance. [Pg.415]

With the availabihty of computers, the transfer matrix method [14] emerged as an alternative and powerful technique for the study of cooperative phenomena of adsorbates resulting from interactions [15-17]. Quantities are calculated exactly on a semi-infinite lattice. Coupled with finite-size scaling towards the infinite lattice, the technique has proved popular for the determination of phase diagrams and critical-point properties of adsorbates [18-23] and magnetic spin systems [24—26], and further references therein. Application to other aspects of adsorbates, e.g., the calculation of desorption rates and heats of adsorption, has been more recent [27-30]. Sufficient accuracy can usually be obtained for the latter without scaling and essentially exact results are possible. In the following, we summarize the elementary but important aspects of the method to emphasize the ease of application. Further details can be found in the above references. [Pg.446]

The introduction of various empirical corrections, such as scale factors for frequencies and energy corrections based on the number of electrons and degree of spin contamination, blurs the distinction between whether they should be considered ab initio, or as belonging to the semi-empirical class of methods, such as AMI and PM3. Nevertheless, the accuracy tiiat tiiese methods are capable of delivering makes it possible to calculate absolute stabilities (heat of formation) for small and medium sized systems which rival (or surpass) experimental data, often at a substantial lower cost than for actually performing the experiments. [Pg.169]

The most difficult materials to study by NMR microscopy are those with short T2 or T2 relaxation times and/or with low concentrations of the nudear spins, which normally result in poor NMR signal intensities. One possibility for improving the image quality is to adapt the shape and size of the rf coils to the size of the objects in order to achieve the best possible filling factor and therefore the best sensitivity [1]. In addition, methods with short echo or detection times have been developed, such... [Pg.47]

The essence of the DDIF method is to first establish a spin magnetization modulation that follows the spatial variation of the internal magnetic field within the individual pore. Such modulation is created by allowing spins to precess in the internal magnetic field. Then the diffusion-driven time-evolution (often decay) of such a modulation is monitored through a series of signal measurements at various evolution times tD. The time constant of this decay corresponds to the diffusion time of a molecule (or spin) across the pore and thus is a direct measure of the pore size. [Pg.342]


See other pages where Size methods spinning is mentioned: [Pg.196]    [Pg.367]    [Pg.12]    [Pg.77]    [Pg.25]    [Pg.432]    [Pg.262]    [Pg.92]    [Pg.143]    [Pg.282]    [Pg.51]    [Pg.481]    [Pg.519]    [Pg.943]    [Pg.94]    [Pg.515]    [Pg.457]    [Pg.483]    [Pg.311]    [Pg.233]    [Pg.102]    [Pg.735]    [Pg.177]    [Pg.201]    [Pg.151]    [Pg.937]    [Pg.711]    [Pg.365]    [Pg.229]    [Pg.11]    [Pg.112]    [Pg.207]    [Pg.35]    [Pg.213]    [Pg.141]    [Pg.340]    [Pg.436]    [Pg.439]    [Pg.443]    [Pg.136]    [Pg.340]    [Pg.217]   
See also in sourсe #XX -- [ Pg.298 ]




SEARCH



Size methods

Size methods spinning solution additive

Spinning methods

© 2024 chempedia.info