Separation selectivity testing

In order to classify promiscuous and selective compounds, we used the NB modeling protocol available in Pipeline Pilot (Scitegic) [53]. The data was split randomly into 5193 compounds for modeling and 574 compounds for testing the models. In addition to the test set, 302 known drugs were also profiled and kept separate for testing the models. All sets were checked visually to ensure that no chemical classes were overrepresented in one set or the other. [Pg.307]

Critical separations in chromatography should be investigated at an appropriate level. For critical separations, selectivity can be demonstrated by the resolution of the two components that elute closest to each other. Peak purity tests using diode array or mass spectrometric detectors may be useful to show that the analyte chromatographic peak is not attributable to more than one component. [Pg.751]

The essential aspect of computer-based analysis of concerted evolution is the search for similarity between physically separated parts of a given sequence. Two approaches can be used for such searches graphical comparison of an entire sequence with itself (or with a carefully selected test sequence) or a straightforward listing of regions of sequence similarity... [Pg.535]

Figure 18-13. Separation of phase selectivity test mixture of phenanthro[3,4-c]phenan-threne (PhPh), 1,2 3,4 5,5 7,8-tetrabenzonaphthalene (TBN), and benzo[ ]pyrene (BaP) on polymeric C18 phase (Vydac) at subambient temperatures. (Reproduced from reference 81, with permission. Copyright 1989, American Chemical Society.)... Figure 18-13. Separation of phase selectivity test mixture of phenanthro[3,4-c]phenan-threne (PhPh), 1,2 3,4 5,5 7,8-tetrabenzonaphthalene (TBN), and benzo[ ]pyrene (BaP) on polymeric C18 phase (Vydac) at subambient temperatures. (Reproduced from reference 81, with permission. Copyright 1989, American Chemical Society.)...
This cost differential can be tolerated only in applications in which polymeric membranes completely fail in the separation [78]. Demanding separation applications, where zeolite membranes could be justified, due to the high temperatures involved or the added value of the components, and have been tested at laboratory scale, are the following separation of isomers (i.e., butane isomers, xylene isomers), organic vapor separations, carbon dioxide from methane, LNG (liquefied natural gas) removal, olefines/paraffins and H2 from mixtures. In most cases, the separation is based on selective diffusion, selective adsorption, pore-blocking effects, molecular sieving, or combinations thereof. The performance or efficiency of a membrane in a mixture is determined by two parameters the separation selectivity and the permeation flux through the membrane. [Pg.283]

Gas-sensing electrodes are examples of multiple membrane sensors these contain a gas-permeable membrane separating the test solution from an internal thin electrolyte film in which an ion-selective electrode is immersed. For example, for the ammonia sensor, the pH of the recipient layer is determined by the Henderson-Hasselbach equation [Eq. (18)], derived from the chemical equilibrium between solvated ammonia and ammonium ions ... [Pg.1508]

The simplest form of an HPLC SST involves comparison of the chromatogram with a standard one, allowing comparison of the peak shape and the peak width baseline resolution. Additional parameters that can be experimentally calculated to provide quantitative SST report include the number of theoretical plates, separation factor, resolution, tailing or peak asymmetry factor, accuracy, and precision (RSD of six measurements). Resolution may also be combined with a selectivity test to check the resolution of the analytes from components present in the sample matrix. If matrix components interfere with a method, a matrix blank may be included in the SST. Peak shape and asymmetry, or tailing factor, can... [Pg.1704]

In summary, separator selection calls for clear problem definition, in broad terms thorough cataloging of process information and preliminary and tentative equipment selection, followed by refinement of the initial selections through tests on an increasingly larger scale. Reliability, flexibility of operation, and ease of maintenance should be weighed heavily in the final economic evaluation rarely is purchase... [Pg.2086]

The Prontosil column is very similar to, although not identical with, Genesis. It could be used as an alternative if the latter one is not available. On the other hand, the Platinum is very different and cannot be used as a substitute. However, it could be interesting to use it in order to check if all peaks of a mixture are separated in the course of selectivity tests during validation. [Pg.183]

Back in 1978, Kaimai and Matsunaga tried to separate PAHs and PASHs by thin layer chromatography on silica gel impregnated with several metal acetates. Mercury acetate showed the best results. Following that idea, separation was tested by Andersson on a mercury-acetate-substituted phenyl kieselguhr. However, PASHs could not be separated selectively. [Pg.352]

It is not possible to devise a comprehensive separation scheme for anions however, it is possible to detect them individually in most cases, after perhaps a 1-2 stage separation. It is advantageous to remove all heavy metals from the sample by extracting the anions through boiling with sodium carbonate solution heavy metal ions are precipitated out in the form of carbonates, while the anions remain in solution accompanied by sodium ions. The selected tests are listed in order of increasing complexity it is advisable to do them in the order they are described. [Pg.265]


See other pages where Separation selectivity testing is mentioned: [Pg.429]    [Pg.1751]    [Pg.152]    [Pg.23]    [Pg.340]    [Pg.429]    [Pg.88]    [Pg.613]    [Pg.346]    [Pg.679]    [Pg.9]    [Pg.169]    [Pg.178]    [Pg.526]    [Pg.173]    [Pg.167]    [Pg.193]    [Pg.176]    [Pg.102]    [Pg.353]    [Pg.1755]    [Pg.152]    [Pg.249]    [Pg.250]    [Pg.252]    [Pg.254]    [Pg.256]    [Pg.258]    [Pg.260]    [Pg.262]    [Pg.264]    [Pg.266]    [Pg.268]    [Pg.270]    [Pg.272]   
See also in sourсe #XX -- [ Pg.442 , Pg.443 , Pg.444 ]