Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensitizers Ir

The most powerful teclmique for studying VER in polyatomic molecules is the IR-Raman method. Initial IR-Raman studies of a few systems appeared more than 20 years ago [16], but recently the teclmique has taken on new life with newer ultrafast lasers such as Ti sapphire [39]. With more sensitive IR-Raman systems based on these lasers, it has become possible to monitor VER by probing virtually every vibration of a polyatomic molecule, as illustrated by recent studies of chlorofonn [40], acetonitrile [41, 42] (see example C3.5.6.6 below) and nitromethane [39, 43]. [Pg.3035]

Zirconocene dichloride (bis[cyclopentadienyl]zirconium dichloride) [1291-32-3] M 292.3, m 242-245 , 248 . Purified by recrystn from CHCI3 or xylene, and dried in vacuum. H NMR (CDCI3) 8 6.52 from MeaSi. Store in the dark under N2 as it is moisture sensitive. [IR, NMR, MS Aust J Chem 18 173 7965 method of J Am Chem Soc 81 1364 7959 and references in the previous entry.]... [Pg.499]

Time resolution is a strength of modern FTIR spectrometers that makes them powerful tools for investigations of fast processes. For the investigation of slow processes, the same single-beam FT spectrometers have a disadvantage sensitive IR measurements require the acquisition of a reference spectrum, which is usually done... [Pg.266]

Most SHG studies involve incident energies in the visible or near-infrared spectrum. Infrared SHG studies are hindered by the current lack of sufficiently sensitive IR detectors. However, the sum frequency generation (SFG) technique allows one to obtain surface-specific vibrational spectra. In SFG, two lasers are focused on the sample surface, one with a fixed frequency in the visible and one with a tunable range of IR frequencies. The sample surface experiences the sum of these frequencies. When the frequency of the infrared component corresponds to a molecular vibrational mode, there is an increase in the total SHG signal, which is detected at the visible frequency [66]. The application of such... [Pg.429]

In this chapter a new technique for the IR spectroscopic analysis of individual microscopic components in coals is described. This method combines new procedures for preparing uncontaminated thin section specimens of coal with a sensitive IR microspectrophotometer which has recently become commercially available. Details of this new technique are discussed and some representative spectra are described. [Pg.55]

In addition to transmission experiments, it is possible to use more sensitive reflectance protocols. In particular, in internal reflectance spectroscopy (IRS) the lightbeam is introduced to the electrode at an angle, and the spectrum are recorded from the reflected beam at the solid-solution interface. Prisms are used to let the radiation enter and leave. Besides its higher sensitivity, IRS is less prone to solution resistance effects. [Pg.46]

Table 6. Conformational-sensitive IR bonds in networks and model compounds, 9)... Table 6. Conformational-sensitive IR bonds in networks and model compounds, 9)...
Table 3.11 Position (cm ) of the sensitive IR bands of adsorbed basic probe molecules on different catalyst surfaces. The Lewis acid strength roughtly decreases from top to bottom. Table 3.11 Position (cm ) of the sensitive IR bands of adsorbed basic probe molecules on different catalyst surfaces. The Lewis acid strength roughtly decreases from top to bottom.
Ex situ IR data are collected on dried, diluted powder films in a low vacuum enviromnent or one purged with a dry gas such as N2. Attenuated total reflectance (ATR)-IR spectroscopy provides surface-sensitive IR measurements and can be used for in situ studies of sorption phenomena. Raman spectroscopy is a related vibrational spectroscopy that provides complimentary information to IR. It can also be used to collect vibrational spectra of aqueous samples. Typical data reduction for vibrational spectra involves subtraction of a background spectmm collected under identical conditions from the raw, averaged sample spectrum. Data analysis usually consists of an examination of changes in peak position and shape and peak fitting (Smith, 1996). These and other spectral parameters are tracked as a function of maaoscopic variables such as pH, adsorption density, and ionic strength. [Pg.32]

Check it 3.3.2.2 illustrates the phase correction of a phase sensitive IR COSY TPPI spectrum whilst in Check it 3.3.2.3 a phase sensitive COSY spectrum with double quantum filter is simulated. The double quantum filter effects the lineshape in the spectrum such that the diagonal and cross peaks have a narrower absorptive lineshape. [Pg.101]

Isomorphous substitution of the framework aluminium of ZSM-5 for zinc The gas-solid reaction of anhydrous ZnClz vapor with HZSM-5 was studied at 773 K. The retention of the crystallinity of the zeolite after the reaction was confirmed by XRD results. Figure 1 shows the change in the volume of the crystalline unit cell, Vu.c., and the frequency of the framework-sensitive IR absorption near 1100 cm during the reaction. The result that the product zeolite of the reaction has an Vu.c. value greater than that for the initial HZSM-5 indicates that the zinc atom is inserted into the zeolite framework since the bond of Zn-0(1.96 A) is longer than Al-0(1.75 A) and Si-0(1.61 A). The linear relationship between Vu.c. and the reaction time suggests that the insertion of zinc is proportional to the reaction period. The continuous shift in the framework-sensitive IR absorption frequency towards lower wavenumbers provides further evidence... [Pg.208]

Figure 1. Variation of Vu.c, and the framework sensitive IR absorption frequency during the gas-solid reaction. Figure 1. Variation of Vu.c, and the framework sensitive IR absorption frequency during the gas-solid reaction.
Both the intensity and the frequency of the -OH stretch in water are critically dependent upon the extent of hydrogen bonding to the immediate environment [40] and thus is a sensitive probe of the various types of water existing at the electrode-electrolyte interface. However, there are additional physical effects that may be detected by the phase-sensitive IR-ATR technique such as those derived from the variation of the electric field at the surface these electroreflectance effects are primarily due to changes in the surface electron density. [Pg.21]

LC devices vary between 1 and 0.07 p.p.b. of quinine sulphate as equivalent to the noise. Quinine sulphate is one of the most sensitive compounds for fluorimetric detection (high quantum yield) for a compound with a high sensitivity ir UV photometric detectioh (molar absorptivity 50,000, molar weight 300), current noise -4... [Pg.126]

Infrared Spectral Correlations vntbv. Certain infrared spectral vibration frequencies and parameters derived therefrom show good linearity with the w scale and may also qualify as 7r -type properties. That linear solvation energy relationships (LSERs) apply to ir spectra was first pointed out by Allerhand and Schleyer (34/), who reported that solvent shifts of various types of ir stretching frequencies are proportional to one another. Based on this proportionality, they proposed an empirical LSER for the correlation of solvent sensitive ir vibration frequencies. [Pg.564]

Fig. 6.14. Series-parallel scan IR CID. Infrared sensitive IR CID modules are completely read out more than once a dwell time through a preamplifier into a silicon CCD signal processor. In the signal processor TDI is performed and then th% individual lines of imagery are ac coupled and multiplexed. Only the CID module itself is fabricated from IR sensitive material... Fig. 6.14. Series-parallel scan IR CID. Infrared sensitive IR CID modules are completely read out more than once a dwell time through a preamplifier into a silicon CCD signal processor. In the signal processor TDI is performed and then th% individual lines of imagery are ac coupled and multiplexed. Only the CID module itself is fabricated from IR sensitive material...

See other pages where Sensitizers Ir is mentioned: [Pg.368]    [Pg.44]    [Pg.211]    [Pg.79]    [Pg.233]    [Pg.71]    [Pg.37]    [Pg.435]    [Pg.1835]    [Pg.6384]    [Pg.297]    [Pg.532]    [Pg.784]    [Pg.209]    [Pg.304]    [Pg.151]    [Pg.154]    [Pg.1834]    [Pg.6383]    [Pg.44]    [Pg.53]    [Pg.94]    [Pg.205]    [Pg.8]    [Pg.290]    [Pg.15]    [Pg.62]   
See also in sourсe #XX -- [ Pg.3 , Pg.385 , Pg.424 ]




SEARCH



How to Isolate Potential-sensitive IR Absorption

IR sensitivity

IR sensitivity

© 2024 chempedia.info