Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Selection of Suitable Liquid Ring Vacuum Pumps

LRVPs should be operated with suction pressures below the double vapour pressure of the ring liquid delivered on the pressure side with a gas ejector. With the aid of the ejector, the gas to be sucked off is compressed and the LRVP is fed with higher pressure. The result is an increase in the suction capacity of the working point. Furthermore, the noise developments are prevented by flow separations. [Pg.51]

The supplied quantity of operating liquid should not exceed the preset data. [Pg.51]

An overstepping of the presetting produces a back pressure of the liquid in the vacuum pump. This leads to an increase in the internal compression ratios and therewith also to the increase in the power consumption. The results can be an overloading of the components as well as an intensified noise development by flow separations. [Pg.51]

With the extraction of the vapours condensable in the vacuum pump, attention is to be paid to a sufficient inert gas portion. Otherwise, intensified noise developments are to be expected by the condensation in the course of the compression likewise by flow separations. [Pg.51]

Selection of Suitable Liquid Ring Vacuum Pumps [Pg.51]


Selection of Suitable Liquid Ring Vacuum Pumps 51... [Pg.51]