Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Seal fittings

The outside diameter of the lip. seal fits and seats into the housing bore (transmission or pump). The inside diameter, with the elastomeric lip, rides onto the spinning shaft (whether vehicular drive shaft or pump shaft). [Pg.169]

Conduit and cable sealing fittings as shown in Figures 17-25 and 17-26 are provided for the following purposes ... [Pg.535]

Figure 17-25. Standard sealing fittings. [Courtesy of Crouse-Hinds Electrical Construction Materials, a division of Cooper Industries, Inc.]... Figure 17-25. Standard sealing fittings. [Courtesy of Crouse-Hinds Electrical Construction Materials, a division of Cooper Industries, Inc.]...
Special sealing fittings (not yet commercially available) are required for cables and conduits connected to process connections that depend on a single seal, diaphragm, or tube to prevent process fluid... [Pg.539]

Cable termination fittings are available which also are approved as sealing fittings, and often incorporate a union in their design. Particularly for space-limited installations, the difference in length requirements for such dual-purpose devices, as compared to standard sealing fitting/cable terminator/union combinations, can be consequential. [Pg.540]

When seal fittings are installed, certain mechanical practices must be followed. The following requirements are often overlooked by both installers and inspectors ... [Pg.540]

Accessibility. Sealing fittings should not be installed behind walls or in other inaccessible locations. [Pg.540]

Splices. Splices and taps may not be made in sealing fittings. Most sealing compounds are poor insulators, and electrical shorts could occur. [Pg.541]

Make sure all rotary unit parts of the seal fit over the shaft freely. [Pg.952]

Fig. 10.7. Flange tubing connectors, (a) Cajon VCO O-ring sealed Fitting (b) Cajon VCR metal gasketed flange fitting. (Reproduced by permission of the copyright holder, Markad Services Co.)... Fig. 10.7. Flange tubing connectors, (a) Cajon VCO O-ring sealed Fitting (b) Cajon VCR metal gasketed flange fitting. (Reproduced by permission of the copyright holder, Markad Services Co.)...
This e.xception in the Code offers potential savings by the elimination oi costly external seal fittings, and the... [Pg.130]

Several types of dust caps and sealings fitted to the barrel-to-stem chamfer (e.g., Ref. ) are available to prevent contamination of the tablets by machine oil dripping from the upper punch. Alternatively, punch bellows in silicone rubber fitted into special seal grooves for Euro-standard are available (e.g., from Holland, http //www.iholland.co.uk). [Pg.3785]

Suba Seals. Size 33 suba seals fit male 24/40 joints, size 49 fit female 24/40 joints, and size 29 provide a tight fit for female 14/20. Smaller sizes are often useful for specialized apparatus such as solution infrared cells. Suba seals are available from two suppliers in this country Aldrich and Strem Chemicals. [Pg.22]

Hydrogen leaks typically originate from valves, flanges, diaphragms, gaskets, seals, fittings. [Pg.229]

Injection molding permits better dimensional accuracy, which may be of important advantage for proper sealing (fit) of the matching lid. [Pg.17]

The mobile phase flow rate should be checked to ensure that the set flow is being accurately delivered. Errors in the flow can be attributed to siphoning, incorrect operation of the one-way check valves in the pump heads or worn seals. Fitting a backpressure regulator downstream of the column stops siphoning and will force the one-way check valves to operate correctly. [Pg.2237]

A fuel channel encloses the fuel bundle the combination of a fuel bundle and a fuel channel is called a fuel assembly. The channel is a square-shaped tube fabricated from Zircaloy 4 its outer dimensions are 5.455 in. (138.6 mm) x 5.455 in. (138.8 mm) x 166.9 in. (4.2 m) long. The reusable channel makes a sliding seal fit on the lower tie plate surface. The channel fastener assembly (consisting of a spring and a guard) attaches the reusable channel to the upper tie plate and a capscrew secured by a lock washer. Spacer buttons are located on two sides of the channel to properly space four assemblies within a core cell. The fuel channels direct the core coolant flow through each fuel bundle and also serve to guide the control rod assemblies. [Pg.113]

A serious manufacturing defect has been found in the seals seals fitted to Nimrods after 2000 have been found to contain 50% less carbon black filler Oran earlier seals. This has made them prone to swelling and splitting and reduced their fatigue life. [Pg.144]

Seal adapters on testing units for printed IC boards. These must be sealed to maintain test temperatures from -50 °C to 150 °C (-58 °F to 302 °F), and PAI can provide better dimensional stability for a tighter seal fit and offer longer part life than traditional materials. [Pg.32]

Storage of the system will require the electrode to be kept wet, either in situ, or removed from the unit. Similarly it may be necessary to protect the electrode during cleaning from, for instance, hot caustic solutions, in which case a self sealing fitting or other means of isolation is required. [Pg.22]


See other pages where Seal fittings is mentioned: [Pg.534]    [Pg.535]    [Pg.539]    [Pg.540]    [Pg.540]    [Pg.523]    [Pg.379]    [Pg.380]    [Pg.381]    [Pg.379]    [Pg.380]    [Pg.381]    [Pg.130]    [Pg.146]    [Pg.422]    [Pg.380]    [Pg.641]    [Pg.90]    [Pg.95]    [Pg.259]    [Pg.234]   
See also in sourсe #XX -- [ Pg.535 , Pg.536 , Pg.537 , Pg.538 , Pg.539 , Pg.540 ]




SEARCH



Fittings conduit sealing

Fittings seal installation

Fittings sealing

Fittings sealing

Gas locks and seal-off fittings

Pipe fitting, sealing

© 2024 chempedia.info