Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scaling functions experimental tests

In the crude analysis the high-lead children scored lower on the WISC when compared to low-lead children, especially on the Verbal IQ (p < 0.001) and Full Scale IQ (p < 0.01). There was no significant difference between the high- and low-exposure groups on the Performance IQ or on the different experimental tests. However, impaired function associated with lead exposure was also found on the Bender Visual Motor Gestalt Test (p < 0.001) and on the behavioural rating (p < 0.03). [Pg.245]

Overall, the accuracy reached by the hybrid functionals tested is quite pleasing, in particular if we keep in mind the favorable scaling of computational demands and the obviously much lower basis set requirements. The binding energy of the water molecule computed with the B3LYP and the mPWIPW functional miss the lower experimental error bar by only 0.1 kcal/mol and approach quite closely the best available conventional wave function based data. [Pg.242]

In this review, the potential uses of sonochemistry for the preparation of monometallic and bimetallic metal nanoparticles and metal-loaded semiconductor nanoparticles have been highlighted. While specific examples available in the literature were discussed, the sonochemical technique seems to offer a platform technique that could be used for synthesizing a variety of functional materials. Most of the studies to date deal with laboratory scale exploration , it would be ideal if the concepts are tested under large scale experimental conditions involving specific applications. The authors sincerely hope that the information provided in this review would prompt such experimental investigation in a new dimension. [Pg.165]

Heat and mass balance equations are used in all aspects of process modelling however, what is key to this model is an understanding of the electrolytic process behind the cell. For example, the model must be able to predict current efficiency and k-factor if it is to predict electricity consumption. Most of these electrolytic parameters are calculated using empirical relationships derived from experimental data both from test cells and the full-scale plant. Considering k-factor, this is primarily a function of brine strength and temperature. Figure 20.5 illustrates the experimentally derived function used in the model. [Pg.263]

The rotational relaxation of DNA from 1 to 150 ns is due mainly to Brownian torsional (twisting) deformations of the elastic filament. Partial relaxation of the FPA on a 30-ns time scale was observed and qualitatively attributed to torsional deformations already in 1970.(15) However, our quantitative understanding of DNA motions in the 0- to 150-ns time range has come from more accurate time-resolved measurements of the FPA in conjunction with new theory and has developed entirely since 1979. In that year, the first theoretical treatments of FPA relaxation by spontaneous torsional deformations appeared. 16 171 and the first commercial synch-pump dye laser systems were delivered. Experimental confirmation of the predicted FPA decay function and determination of the torsional rigidity of DNA were first reported in 1980.(18) Other labs 19 21" subsequently reported similar results, although their anisotropy formulas were not entirely correct, and they did not so rigorously test the predicted decay function or attempt to fit likely alternatives. The development of new instrumentation, new data analysis techniques, and new theory and their application to different DNAs in various circumstances have continued to advance this field up to the present time. [Pg.139]


See other pages where Scaling functions experimental tests is mentioned: [Pg.319]    [Pg.150]    [Pg.151]    [Pg.140]    [Pg.96]    [Pg.319]    [Pg.11]    [Pg.134]    [Pg.135]    [Pg.811]    [Pg.190]    [Pg.127]    [Pg.6]    [Pg.11]    [Pg.336]    [Pg.779]    [Pg.180]    [Pg.101]    [Pg.87]    [Pg.240]    [Pg.361]    [Pg.350]    [Pg.213]    [Pg.293]    [Pg.1240]    [Pg.127]    [Pg.287]    [Pg.137]    [Pg.39]    [Pg.263]    [Pg.109]    [Pg.77]    [Pg.210]    [Pg.93]    [Pg.303]    [Pg.83]    [Pg.138]    [Pg.148]    [Pg.248]    [Pg.165]    [Pg.33]    [Pg.68]    [Pg.182]    [Pg.349]    [Pg.119]    [Pg.119]   
See also in sourсe #XX -- [ Pg.401 ]




SEARCH



Functional testing

Functional tests

Scale functions

Scale testing

Scaling functions

Test function

© 2024 chempedia.info