Sample steady

The second Interesting observation based on ICR and RMS results Is related to the need for pressure correction In capillary flow. Already In Fig. 19 an agreement between the dynamic viscosity, n, and corrected for pressure effect capillary shear viscosity, n, was shown. In Fig. 22 five different measures of viscosity are shown for LLDPE-A (four for the other samples) steady state elongational viscosity, nE/3 conqplex and dynamic viscosity, n and n > as well as the steady state capillary viscosity corrected and uncorrected for the pressure effects, hcorr n(lCR), respectively. There Is a... [Pg.188]

We will use these relations in Section 5.4.3 to simplify the interpretation of reversible sampled-current voltammograms in various chemical situations. The reader interested in a quick view of applications can proceed directly to that point and beyond. However, a full view of reversible waves needs to include those recorded by sampling steady-state currents, so the next section is devoted to that topic. [Pg.180]

This trend may reflect the fact that the surface of pores increases approximately as the square, whereas their volume increases approximately as the cube of the pore size. As shown in the figure, the shape of the dye adsorption curve is similar to that of the apparent capillary pressure curve. In the tests conducted with this sample steady state was reached at every point much sooner than in the water-wet sample and desorption of dye was much less, too. [Pg.474]

Both forms sublime very readily, even at room temperature a small sample on exposure to the air will completely volatilise in a short time, particularly on a warm day or if the sample is exposed to a gentle current of air. Hence the above method for rapid drying. A sample confined in an atmospheric desiccator over calcium chloride rapidly disappears as the vapour is adsorbed by the calcium chloride. A sample of the hexahydrate similarly confined over sodium hydroxide undergoes steady dehydration with initial liquefaction, for the m.p. of the hydrated-anhydrous mixture is below room temperature as the dehydration proceeds to completion, complete resolidification occurs. [Pg.150]

Ion-selective electrodes can be incorporated in flow cells to monitor the concentration of an analyte in standards and samples that are pumped through the flow cell. As the analyte passes through the cell, a potential spike is recorded instead of a steady-state potential. The concentration of K+ in serum has been determined in this fashion, using standards prepared in a matrix of 0.014 M NaCl. ... [Pg.536]

A 2.00-mb sample of a solution containing an unknown amount of glucose is diluted to 10 mb in a volumetric flask, and a steady-state current of 23.6 is measured. What is the concentration of glucose in the sample in milligrams per 100 mb ... [Pg.538]

There are many sources of errors in the plant. The principal ones are related to sampling (qv), mass flow rates, assaying, and deviations from steady state. Collecting representative samples at every stage of the flow sheet constitutes a significant task. Numerous methods and equipment are available (10,16,17). [Pg.395]

The characteristic separation curve can be deterrnined for any size separation device by sampling the feed, and coarse and fine streams during steady-state operation. A protocol for determining such selectivity functions has been pubHshed (4). This type of testing, when properly conducted, provides the relationships among d K, and a at operating conditions. These three parameters completely describe a size separation device and can be used to predict the size distribution of the fine and coarse streams. [Pg.434]

Oxygen Transport. The most widely used methods for measuring oxygen transport are based upon the Ox-Tran instmment (Modem Controls, Inc.). Several models exist, but they all work on the same principle. The most common apphcation is to measure the permeabihty of a film sample. Typically, oxygen is introduced on one side of the film, and nitrogen gas sweeps the other side of the film to a coulometric detector. The detector measures the rate that oxygen comes through the film. The detector response at steady state can easily be converted to At (eq. 1). Simple... [Pg.499]

Water Transport. Two methods of measuring water-vapor transmission rates (WVTR) ate commonly used. The newer method uses a Permatran-W (Modem Controls, Inc.). In this method a film sample is clamped over a saturated salt solution, which generates the desired humidity. Dry air sweeps past the other side of the film and past an infrared detector, which measures the water concentration in the gas. For a caUbrated flow rate of air, the rate of water addition can be calculated from the observed concentration in the sweep gas. From the steady-state rate, the WVTR can be calculated. In principle, the diffusion coefficient could be deterrnined by the method outlined in the previous section. However, only the steady-state region of the response is serviceable. Many different salt solutions can be used to make measurements at selected humidity differences however, in practice,... [Pg.500]

Because protein samples are actually ampholytes, when samples are loaded onto the gel and a current is appHed, the compounds migrate through the gel until they come to their isoelectric point where they reach a steady state. This technique measures an intrinsic physicochemical parameter of the protein, the pi, and therefore does not depend on the mode of sample appHcation. The highest sample load of any electrophoretic technique may be used, however, sample load affects the final position of a component band if the load is extremely high, ie, high enough to titrate the gradient ampholytes or distort the local electric field. [Pg.181]

A key feature of MFC is that future process behavior is predicted using a dynamic model and available measurements. The controller outputs are calculated so as to minimize the difference between the predicted process response and the desired response. At each sampling instant, the control calculations are repeated and the predictions updated based on current measurements. In typical industrial applications, the set point and target values for the MFC calculations are updated using on-hne optimization based on a steady-state model of the process. Constraints on the controlled and manipulated variables can be routinely included in both the MFC and optimization calculations. The extensive MFC literature includes survey articles (Garcia, Frett, and Morari, Automatica, 25, 335, 1989 Richalet, Automatica, 29, 1251, 1993) and books (Frett and Garcia, Fundamental Process Control, Butterworths, Stoneham, Massachusetts, 1988 Soeterboek, Predictive Control—A Unified Approach, Frentice Hall, Englewood Cliffs, New Jersey, 1991). [Pg.739]

When the operating conditions are uniform and steady (there are no fluctuations in flow rate or in concentration of CO in the gas stream), the continuous sampling method can be used. A sampling probe is placed in the stack at any location, preferably near the center. The sample is extracted at a constant sampling rate. As the gas stream passes through the sampling apparatus, any moisture or carbon dioxide in the sample gas stream is removed. The CO concentration is then measured by a nondispersive infrared analyzer, which gives direct readouts of CO concentrations. [Pg.2201]

To determine if steady state conditions exist, the temperatures and pressures in the column can be tabulated to assure that they are reasonably unchanging. Laboratoiy analyses are usually too slow and expensive for checking lined out conditions. Monitoring reflux accumulator boiloff is often an effective way of noting concentration changes. Simply let a sample of the accumulator liquid boil at atmospheric pressure in a bottle with a thermometer inserted. This method is limited to light hydrocarbons and is not accurate enough for precision fractionation. [Pg.71]

The uncoupled response of a piezoelectric sample to elastic shock compression is determined on the assumption that the mechanical response of the material is independent of any electric fields that may be present. In this approximation, a steady shock is introduced into material at rest while the... [Pg.74]


See other pages where Sample steady is mentioned: [Pg.3142]    [Pg.284]    [Pg.366]    [Pg.3142]    [Pg.284]    [Pg.366]    [Pg.282]    [Pg.1531]    [Pg.1910]    [Pg.1930]    [Pg.1930]    [Pg.1941]    [Pg.2935]    [Pg.2949]    [Pg.186]    [Pg.499]    [Pg.500]    [Pg.1028]    [Pg.727]    [Pg.622]    [Pg.150]    [Pg.76]    [Pg.331]    [Pg.340]    [Pg.396]    [Pg.232]    [Pg.100]    [Pg.468]    [Pg.216]    [Pg.88]    [Pg.323]    [Pg.640]    [Pg.665]    [Pg.223]    [Pg.248]    [Pg.221]    [Pg.325]    [Pg.136]   
See also in sourсe #XX -- [ Pg.6 , Pg.7 ]




SEARCH



Sample quasi-steady

Steady-state compliance polystyrene sample