Safety barriers, intrinsically safe electrical circuits

Safety Barriers. Figure 1 illustrates an application employing intrinsically safe electrical circuits for the demilitarization of ammunition. Three separate areas are required for this application - one area, classified as non-hazardous, to serve as the control and loading area a second area, classified as hazardous, where the actual demilitarization is accomplished and a third area, classified as non-hazardous, is required for the hydraulic pump due to the level of noise produced. [Pg.260]

Due to the galvanic isolation lacking between intrinsically safe and non-intrinsically safe electrical circuits the power-limiting characteristic of components commonly used for it (e.g. small transformers, optocouplers, relays) is lacking as well. So, a robust safety barrier shall be constructed. [Pg.371]

If a high quality equipotential bonding system cannot be put into practice or a steady supply voltage cannot be guaranteed, a galvanic isolation between intrinsically safe and non-intrinsically safe electrical circuits is recommended. Such apparatus, e.g. power supplies for transmitters or switching repeaters, are equivalent to safety barriers with respect to the philosophy of intrinsic safety. The additional feature may be seen in the galvanic isolation and functional characteristics which may be practicable. [Pg.373]

Ordinary electrical equipment cannot be installed in zone 0, even when it is flameproof protected. However, many chemical and oil-processing plants are entirely dependent upon instrumentation and data transmission for their safe operation. Therefore, very low-power instrumentation and data-transmission circuits can be used in special circumstances, but the equipment must be intrinsically safe, and used in conjunction with a safety barrier installed outside the hazardous area. Intrinsically safe equipment must be marked Ex ia or Ex s , specially certified for use in zone 0. [Pg.246]


See other pages where Safety barriers, intrinsically safe electrical circuits is mentioned: [Pg.260]    [Pg.786]    [Pg.610]    [Pg.790]   
See also in sourсe #XX -- [ Pg.260 , Pg.262 ]




SEARCH



Barrier intrinsic

Electrical circuits

Electricity circuits

Intrinsic safety

Intrinsically safe electrical circuits

Safety barrier

Safety barriers, intrinsically safe

Safety electrical

© 2024 chempedia.info